The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyc...The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyclic loading.Prior to the cyclic test,three specimens were exposed to fire and two of them were also subjected to a constant axial load.Test results indicate that the ultimate load of the specimen with lower reinforcement ratio is reduced by 15.8%after exposure to elevated temperatures.While the reductions in the energy dissipation and initial stiffness are 59.2%and 51.8%,respectively,which are much higher than those in the ultimate load.However,this deterioration can be slowed down by properly increasing reinforcement due to the strength and stiffness recovery of steel bars after cooling.In addition,the combined action of elevated temperatures and axial load results in more energy dissipation than the action of fire exposure alone.展开更多
A real case of a steel lattice shell suffering a fire was studied. Based on the theory of field modeling, fire dynamic simulator (FDS) was used to identify the temperature field. The damage mechanism of the structure ...A real case of a steel lattice shell suffering a fire was studied. Based on the theory of field modeling, fire dynamic simulator (FDS) was used to identify the temperature field. The damage mechanism of the structure was determined by FEM analysis. After damage assessment, the shell was repaired with the pipe-encasement method. Finally, field test was employed to check the capacity of the structure after repair. The numerical study results indicate that the damage assessment agrees well with field inspection, verifying the accuracy of fire numerical simulation and FEM analysis. The field test results prove that the pipe-encasement method is secure and reasonable, and the repaired shell is safe.展开更多
基金Project(200801410005) supported by Doctoral Foundation of Ministry of Education of China
文摘The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyclic loading.Prior to the cyclic test,three specimens were exposed to fire and two of them were also subjected to a constant axial load.Test results indicate that the ultimate load of the specimen with lower reinforcement ratio is reduced by 15.8%after exposure to elevated temperatures.While the reductions in the energy dissipation and initial stiffness are 59.2%and 51.8%,respectively,which are much higher than those in the ultimate load.However,this deterioration can be slowed down by properly increasing reinforcement due to the strength and stiffness recovery of steel bars after cooling.In addition,the combined action of elevated temperatures and axial load results in more energy dissipation than the action of fire exposure alone.
基金Supported by National Natural Science Foundation of China (No. 50778122)
文摘A real case of a steel lattice shell suffering a fire was studied. Based on the theory of field modeling, fire dynamic simulator (FDS) was used to identify the temperature field. The damage mechanism of the structure was determined by FEM analysis. After damage assessment, the shell was repaired with the pipe-encasement method. Finally, field test was employed to check the capacity of the structure after repair. The numerical study results indicate that the damage assessment agrees well with field inspection, verifying the accuracy of fire numerical simulation and FEM analysis. The field test results prove that the pipe-encasement method is secure and reasonable, and the repaired shell is safe.