In order to build a power plant with high efficiency,low investment and zero warm water discharge,a series of innovations are applied to the two 1 000-MW units of Ninghai Power Plant.The new technologies include the c...In order to build a power plant with high efficiency,low investment and zero warm water discharge,a series of innovations are applied to the two 1 000-MW units of Ninghai Power Plant.The new technologies include the closed-circuit system for seawater cooling tower with a spraying area of 13 000 m2,the main buildings with reinforced concrete structure,the plasma ignition system for tower boiler and the fieldbus control system.Optimization measures are taken in some aspects,such as the open point of the turbine overload valves,the boiler dimensions,the technical process,the electric system,the building structures and the layout of the power plant.The units have been running for more than half a year with the thermal efficiency as high as 45.79% and without warm water discharged,which indicates that all the systems are safe and steady and the original purpose of optimization has been realized.展开更多
As gas recirculation constitutes a fundamental condition for the realization of MILD combustion, it is necessary to determine gas recirculation ratio before designing MILD combustor. MILD combustion model with gas rec...As gas recirculation constitutes a fundamental condition for the realization of MILD combustion, it is necessary to determine gas recirculation ratio before designing MILD combustor. MILD combustion model with gas recirculation was used in this simulation work to evaluate the effect of fuel type and pressure on threshold gas recirculation ratio of MILD mode. Ignition delay time is also an important design parameter for gas turbine combustor, this parameter is kinetically studied to analyze the effect of pressure on MILD mixture ignition. Threshold gas recirculation ratio of hydrogen MILD combustion changes slightly and is nearly equal to that of 10 MJ/Nm3syngas in the pressure range of 1-19 atm, under the conditions of 298 K fresh reactant temperature and 1373 K exhaust gas temperature, indicating that MILD regime is fuel flexible. Ignition delay calculation results show that pressure has a negative effect on ignition delay time of 10 MJ/Nm3syngas MILD mixture, because OH mole fraction in MILD mixture drops down as pressure increases, resulting in the delay of the oxidation process.展开更多
文摘In order to build a power plant with high efficiency,low investment and zero warm water discharge,a series of innovations are applied to the two 1 000-MW units of Ninghai Power Plant.The new technologies include the closed-circuit system for seawater cooling tower with a spraying area of 13 000 m2,the main buildings with reinforced concrete structure,the plasma ignition system for tower boiler and the fieldbus control system.Optimization measures are taken in some aspects,such as the open point of the turbine overload valves,the boiler dimensions,the technical process,the electric system,the building structures and the layout of the power plant.The units have been running for more than half a year with the thermal efficiency as high as 45.79% and without warm water discharged,which indicates that all the systems are safe and steady and the original purpose of optimization has been realized.
基金supported by National Natural Science Foundation of China(Project No.51006104)National Key Basic Re-search Program of China(No.2014CB247500)
文摘As gas recirculation constitutes a fundamental condition for the realization of MILD combustion, it is necessary to determine gas recirculation ratio before designing MILD combustor. MILD combustion model with gas recirculation was used in this simulation work to evaluate the effect of fuel type and pressure on threshold gas recirculation ratio of MILD mode. Ignition delay time is also an important design parameter for gas turbine combustor, this parameter is kinetically studied to analyze the effect of pressure on MILD mixture ignition. Threshold gas recirculation ratio of hydrogen MILD combustion changes slightly and is nearly equal to that of 10 MJ/Nm3syngas in the pressure range of 1-19 atm, under the conditions of 298 K fresh reactant temperature and 1373 K exhaust gas temperature, indicating that MILD regime is fuel flexible. Ignition delay calculation results show that pressure has a negative effect on ignition delay time of 10 MJ/Nm3syngas MILD mixture, because OH mole fraction in MILD mixture drops down as pressure increases, resulting in the delay of the oxidation process.