In this paper,the performance analysis of recharging the borehole by means of exhaust-air energy is carried out.The results show that a vertical borehole used as heat source for a Ground Source Heat Pump(GSHP)can be r...In this paper,the performance analysis of recharging the borehole by means of exhaust-air energy is carried out.The results show that a vertical borehole used as heat source for a Ground Source Heat Pump(GSHP)can be recharged in high efficiency.With equal heat transfer capabilities of exhaust-air coil and borehole collector,the system provides a maximum overall efficiency.However,due to ground infinite capacity,the optimum brine flow rate is different from conventional two-exchanger system.The recharging system provides two peak overall efficiencies when the capacity ratio Cr=5 for laminar flow and Cr=15 for turbulent flow respectively.The overall efficiency is independent of exhaust-air temperature and undisturbed ground temperature,although the fluid properties depend on temperature.In practical system lower ethyl percentage brine should be chosen if the freezing point meets the system request,which can provide a higher overall efficiency.展开更多
Hydraulic performance of an inlet plenum in a printed-circuit heat exchanger has been analyzed using three-dimensional Reynolds-Averaged Navier-Stokes equations. The numerical model of the inlet plenum was constructed...Hydraulic performance of an inlet plenum in a printed-circuit heat exchanger has been analyzed using three-dimensional Reynolds-Averaged Navier-Stokes equations. The numerical model of the inlet plenum was constructed through grid dependency test, calculation domain tests, and turbulence model and numerical scheme selections. Shear stress transport turbulence model was used for analysis of turbulence. Non-uniformity of the flow in zigzag flow channels was evaluated for the reference case. Parametric studies have been performed with the angle of the inlet plenum wall, radius of curvature of the inlet plenum wall, and width of the inlet pipes. The effects of these parameters on the flow uniformity and friction performance were evaluated.展开更多
文摘In this paper,the performance analysis of recharging the borehole by means of exhaust-air energy is carried out.The results show that a vertical borehole used as heat source for a Ground Source Heat Pump(GSHP)can be recharged in high efficiency.With equal heat transfer capabilities of exhaust-air coil and borehole collector,the system provides a maximum overall efficiency.However,due to ground infinite capacity,the optimum brine flow rate is different from conventional two-exchanger system.The recharging system provides two peak overall efficiencies when the capacity ratio Cr=5 for laminar flow and Cr=15 for turbulent flow respectively.The overall efficiency is independent of exhaust-air temperature and undisturbed ground temperature,although the fluid properties depend on temperature.In practical system lower ethyl percentage brine should be chosen if the freezing point meets the system request,which can provide a higher overall efficiency.
基金supported by the National Research Foundation of Korea (NRF), (Grant No. 2009-0083510)funded by the Korean government (MSIP) through the Multi-phenomena CFD Engineering Research Center
文摘Hydraulic performance of an inlet plenum in a printed-circuit heat exchanger has been analyzed using three-dimensional Reynolds-Averaged Navier-Stokes equations. The numerical model of the inlet plenum was constructed through grid dependency test, calculation domain tests, and turbulence model and numerical scheme selections. Shear stress transport turbulence model was used for analysis of turbulence. Non-uniformity of the flow in zigzag flow channels was evaluated for the reference case. Parametric studies have been performed with the angle of the inlet plenum wall, radius of curvature of the inlet plenum wall, and width of the inlet pipes. The effects of these parameters on the flow uniformity and friction performance were evaluated.