An efficient chlorination roasting process for recovering zinc(Zn)and lead(Pb)from copper smelting slag was proposed.Thermodynamic models were established,illustrating that Zn and Pb in copper smelting slag can be eff...An efficient chlorination roasting process for recovering zinc(Zn)and lead(Pb)from copper smelting slag was proposed.Thermodynamic models were established,illustrating that Zn and Pb in copper smelting slag can be efficiently recycled during the chlorination roasting process.By decreasing the partial pressure of the gaseous products,chlorination was promoted.The Box−Behnken design was applied to assessing the interactive effects of the process variables and optimizing the chlorination roasting process.CaCl_(2) dosage and roasting temperature and time were used as variables,and metal recovery efficiencies were used as responses.When the roasting temperature was 1172℃ with a CaCl_(2) addition amount of 30 wt.%and a roasting time of 100 min,the predicted optimal recovery efficiencies of Zn and Pb were 87.85%and 99.26%,respectively,and the results were validated by experiments under the same conditions.The residual Zn-and Pb-containing phases in the roasting slags were ZnFe_(2)O_(4),Zn_(2)SiO_(4),and PbS.展开更多
A simplified dual-pressure ammonia-water absorption power cycle(DPAPC-a) using low grade energy resources is presented and analyzed.This cycle uses turbine exhaust heat to distill the basic solution for desorption.The...A simplified dual-pressure ammonia-water absorption power cycle(DPAPC-a) using low grade energy resources is presented and analyzed.This cycle uses turbine exhaust heat to distill the basic solution for desorption.The structure of the cycle is simple which comprises evaporator,turbine,regenerator(desorber),absorber,pump and throttle valves for both diluted solution and vapor.And it is of high efficiency,because the working medium has large temperature difference in evaporation and small temperature difference in absorptive condensation,which can match the sensible exothermal heat resource and the cooling water simultaneously.Orthogonal calculation was made to investigate the influence of the working concentration,the basic concentration and the circulation multiple on the cycle performance,with 85-110 ℃ heat resource and 20-32 ℃ cooling water.An optimum scheme was given in the condition of 110 ℃ sensitive heat resource and 20 ℃ cooling water,with the working concentration of 0.6,basic concentration of 0.385,and circulation multiple of 5.The thermal efficiency and the power recovery efficiency are 8.06 % and 6.66%,respectively.The power recovery efficiency of the DPAPC-a is 28.8% higher than that of the steam Rankine cycle(SRC) and 12.7% higher than that of ORC(R134a) under the optimized situation.展开更多
A method for recycling AZ91D magnesium alloy scraps directly by hot extrusion was studied.Various microstructural analyses were performed using the techniques of optical microscopy,scanning electron microscopy(SEM)and...A method for recycling AZ91D magnesium alloy scraps directly by hot extrusion was studied.Various microstructural analyses were performed using the techniques of optical microscopy,scanning electron microscopy(SEM)and energy dispersive spectroscopy(EDS).Microstructural observations revealed that all the recycled specimens consisted of fine grains due to the dynamic recrystallization.The main strengthening mechanism of the recycled specimen was grain refinement strengthening and homogeneous distribution of oxide precipitates.The interfaces of individual scraps of extruded materials were not identified when the scraps were extruded with the extrusion ratio of 40-1.Oxidation layers of the scraps were broken into pieces by high compressive and shear forces under the extrusion ratio of 40-1.The ultimate tensile strength and elongation to failure increased with increasing the extrusion ratio.Recycled specimens with the extrusion ratio of 40:1 showed higher ultimate tensile strength of 342.61 MPa and higher elongation to failure of 11.32%,compared with those of the cast specimen.展开更多
In this paper, a detailed thermodynamic analysis of the pure low-temperature waste heat recovery generation system is presented. The parameters affecting the system performance are compared to obtain the most signific...In this paper, a detailed thermodynamic analysis of the pure low-temperature waste heat recovery generation system is presented. The parameters affecting the system performance are compared to obtain the most significant ones; furthermore, parameter values are optimized for the largest power generating capability of the system. It is found that the most important parameters are inlet flue gas temperature, steam pressure and the pinch point temperature difference. There is an optimal superheated steam pressure value for giving the maximum generation power per unit flue gas. With the increase of inlet flue gas temperature, the generating power increases and the optimized steam pressure rises as well. However, with increase in pinch point temperature difference, the generating power decreases and the optimized steam pressure decreases as well. The theoretical calculation provides a theoretical basis for the parameters optimization in the design of the pure low-temperature waste heat recovery eeneration swtem展开更多
Many F class gas turbine combined cycle (GTCC) power plants are built in China at present because of less emission and high efficiency. It is of great interest to investigate the efficiency improvement of GTCC plant...Many F class gas turbine combined cycle (GTCC) power plants are built in China at present because of less emission and high efficiency. It is of great interest to investigate the efficiency improvement of GTCC plant. A combined cycle with three-pressure reheat heat recovery steam generator (HRSG) is selected for study in this paper. In order to maximize the GTCC efficiency, the optimization of the HRSG operating parameters is performed. The operating parameters are determined by means of a thermodynamic analysis, i.e. the minimization of exergy losses. The influence of HRSG inlet gas temperature on the steam bottoming cycle efficiency is discussed. The result shows that increasing the HRSG inlet temperature has less improvement to steam cycle efficiency when it is over 590℃. Partial gas to gas recuperation in the topping cycle is studied. Joining HRSG optimization with the use of gas to gas heat recuperation, the combined plant efficiency can rise up to 59.05% at base load. In addition, the part load performance of the GTCC power plant gets much better. The efficiency is increased by 2.11% at 75% load and by 4.17% at 50% load.展开更多
Seperated heat pipe systems are widely used in the fields of waste heat recovery and air conditioning due to their high heat transfer capability,and optimization of heat transfer process plays an important role in hig...Seperated heat pipe systems are widely used in the fields of waste heat recovery and air conditioning due to their high heat transfer capability,and optimization of heat transfer process plays an important role in high-efficiency energy utilization and energy conservation.In this paper,the entransy dissipation analysis is conducted for the separated heat pipe system,and the result indicates that minimum thermal resistance principle is applicable to the optimization of the separated heat pipe system.Whether in the applications of waste heat recovery or air conditioning,the smaller the entransy-dissipation-based thermal re-sistance of the separated heat pipe system is,the better the heat transfer performance will be.Based on the minimum thermal resistance principle,the optimal area allocation relationship between evaporator and condenser is deduced,which is numeri-cally verified in the optimation design of separated heat pipe system.展开更多
Waste heat recovery(WHR)is one of the most useful ways to improve the efficiency of internal combustion engines,and an electricity-cooling cogeneration system(ECCS)based on Rankin-absorption refrigeration combined cyc...Waste heat recovery(WHR)is one of the most useful ways to improve the efficiency of internal combustion engines,and an electricity-cooling cogeneration system(ECCS)based on Rankin-absorption refrigeration combined cycle for the WHR of gaseous fuel engines is proposed in the paper.This system can avoid wasting the heat in condenser so that the efficiency of the whole WHR system improves,but the condensing temperature of Rankin cycle(RC)must increase in order to use absorption refrigeration system,which leads to the decrease of RC output power.Therefore,the relationship between the profit of absorption refrigeration system and the loss of RC in this combined system is the mainly studied content in the paper.Because the energy quality of cooling and electricity are different,cooling power in absorption refrigeration is converted to corresponding electrical power consumed by electric cooling system,which is defined as equivalent electrical power.With this method,the effects of some important operation parameters on the performance of the ECCS are researched,and the equivalent efficiency,exergy efficiency and primary energy rate are compared in the paper.展开更多
基金The authors are grateful for the financial supports from the National Natural Science Foundation of China(Nos.51620105013,51904351)Innovation-Driven Project of Central South University,China(No.2020CX028)+1 种基金Natural Science Fund for Distinguished Young Scholar of Hunan Province,China(No.2019JJ20031)the National Key R&D Program of China(No.2019YFC1907400)。
文摘An efficient chlorination roasting process for recovering zinc(Zn)and lead(Pb)from copper smelting slag was proposed.Thermodynamic models were established,illustrating that Zn and Pb in copper smelting slag can be efficiently recycled during the chlorination roasting process.By decreasing the partial pressure of the gaseous products,chlorination was promoted.The Box−Behnken design was applied to assessing the interactive effects of the process variables and optimizing the chlorination roasting process.CaCl_(2) dosage and roasting temperature and time were used as variables,and metal recovery efficiencies were used as responses.When the roasting temperature was 1172℃ with a CaCl_(2) addition amount of 30 wt.%and a roasting time of 100 min,the predicted optimal recovery efficiencies of Zn and Pb were 87.85%and 99.26%,respectively,and the results were validated by experiments under the same conditions.The residual Zn-and Pb-containing phases in the roasting slags were ZnFe_(2)O_(4),Zn_(2)SiO_(4),and PbS.
基金Project(50976022) supported by the National Natural Science Foundation of ChinaProject(BY2011155) supported by Science and Technology Innovation and Transformation of Achievements of Special Fund of Jiangsu Province, China
文摘A simplified dual-pressure ammonia-water absorption power cycle(DPAPC-a) using low grade energy resources is presented and analyzed.This cycle uses turbine exhaust heat to distill the basic solution for desorption.The structure of the cycle is simple which comprises evaporator,turbine,regenerator(desorber),absorber,pump and throttle valves for both diluted solution and vapor.And it is of high efficiency,because the working medium has large temperature difference in evaporation and small temperature difference in absorptive condensation,which can match the sensible exothermal heat resource and the cooling water simultaneously.Orthogonal calculation was made to investigate the influence of the working concentration,the basic concentration and the circulation multiple on the cycle performance,with 85-110 ℃ heat resource and 20-32 ℃ cooling water.An optimum scheme was given in the condition of 110 ℃ sensitive heat resource and 20 ℃ cooling water,with the working concentration of 0.6,basic concentration of 0.385,and circulation multiple of 5.The thermal efficiency and the power recovery efficiency are 8.06 % and 6.66%,respectively.The power recovery efficiency of the DPAPC-a is 28.8% higher than that of the steam Rankine cycle(SRC) and 12.7% higher than that of ORC(R134a) under the optimized situation.
基金Projects(50674038, 50974048) supported by the National Natural Science Foundation of ChinaProject(200802140004) supported by Doctoral Fund of Ministry of Education of China
文摘A method for recycling AZ91D magnesium alloy scraps directly by hot extrusion was studied.Various microstructural analyses were performed using the techniques of optical microscopy,scanning electron microscopy(SEM)and energy dispersive spectroscopy(EDS).Microstructural observations revealed that all the recycled specimens consisted of fine grains due to the dynamic recrystallization.The main strengthening mechanism of the recycled specimen was grain refinement strengthening and homogeneous distribution of oxide precipitates.The interfaces of individual scraps of extruded materials were not identified when the scraps were extruded with the extrusion ratio of 40-1.Oxidation layers of the scraps were broken into pieces by high compressive and shear forces under the extrusion ratio of 40-1.The ultimate tensile strength and elongation to failure increased with increasing the extrusion ratio.Recycled specimens with the extrusion ratio of 40:1 showed higher ultimate tensile strength of 342.61 MPa and higher elongation to failure of 11.32%,compared with those of the cast specimen.
文摘In this paper, a detailed thermodynamic analysis of the pure low-temperature waste heat recovery generation system is presented. The parameters affecting the system performance are compared to obtain the most significant ones; furthermore, parameter values are optimized for the largest power generating capability of the system. It is found that the most important parameters are inlet flue gas temperature, steam pressure and the pinch point temperature difference. There is an optimal superheated steam pressure value for giving the maximum generation power per unit flue gas. With the increase of inlet flue gas temperature, the generating power increases and the optimized steam pressure rises as well. However, with increase in pinch point temperature difference, the generating power decreases and the optimized steam pressure decreases as well. The theoretical calculation provides a theoretical basis for the parameters optimization in the design of the pure low-temperature waste heat recovery eeneration swtem
文摘Many F class gas turbine combined cycle (GTCC) power plants are built in China at present because of less emission and high efficiency. It is of great interest to investigate the efficiency improvement of GTCC plant. A combined cycle with three-pressure reheat heat recovery steam generator (HRSG) is selected for study in this paper. In order to maximize the GTCC efficiency, the optimization of the HRSG operating parameters is performed. The operating parameters are determined by means of a thermodynamic analysis, i.e. the minimization of exergy losses. The influence of HRSG inlet gas temperature on the steam bottoming cycle efficiency is discussed. The result shows that increasing the HRSG inlet temperature has less improvement to steam cycle efficiency when it is over 590℃. Partial gas to gas recuperation in the topping cycle is studied. Joining HRSG optimization with the use of gas to gas heat recuperation, the combined plant efficiency can rise up to 59.05% at base load. In addition, the part load performance of the GTCC power plant gets much better. The efficiency is increased by 2.11% at 75% load and by 4.17% at 50% load.
基金supported by the National Natural Science Foundation of China (Grant Nos. 50906042,51036003)
文摘Seperated heat pipe systems are widely used in the fields of waste heat recovery and air conditioning due to their high heat transfer capability,and optimization of heat transfer process plays an important role in high-efficiency energy utilization and energy conservation.In this paper,the entransy dissipation analysis is conducted for the separated heat pipe system,and the result indicates that minimum thermal resistance principle is applicable to the optimization of the separated heat pipe system.Whether in the applications of waste heat recovery or air conditioning,the smaller the entransy-dissipation-based thermal re-sistance of the separated heat pipe system is,the better the heat transfer performance will be.Based on the minimum thermal resistance principle,the optimal area allocation relationship between evaporator and condenser is deduced,which is numeri-cally verified in the optimation design of separated heat pipe system.
基金supported by the National Basic Research Program of China("973"Project)(Gran No.2011CB707201)
文摘Waste heat recovery(WHR)is one of the most useful ways to improve the efficiency of internal combustion engines,and an electricity-cooling cogeneration system(ECCS)based on Rankin-absorption refrigeration combined cycle for the WHR of gaseous fuel engines is proposed in the paper.This system can avoid wasting the heat in condenser so that the efficiency of the whole WHR system improves,but the condensing temperature of Rankin cycle(RC)must increase in order to use absorption refrigeration system,which leads to the decrease of RC output power.Therefore,the relationship between the profit of absorption refrigeration system and the loss of RC in this combined system is the mainly studied content in the paper.Because the energy quality of cooling and electricity are different,cooling power in absorption refrigeration is converted to corresponding electrical power consumed by electric cooling system,which is defined as equivalent electrical power.With this method,the effects of some important operation parameters on the performance of the ECCS are researched,and the equivalent efficiency,exergy efficiency and primary energy rate are compared in the paper.