SiC films were prepared by modified heating polystyrene/silica bilayer method on Si(111) substrate in normal pressure flowing Ar ambient at 1300℃ . The films were investigated by Fourier transform infrared absorpti...SiC films were prepared by modified heating polystyrene/silica bilayer method on Si(111) substrate in normal pressure flowing Ar ambient at 1300℃ . The films were investigated by Fourier transform infrared absorption, X-ray diffraction, and scanning electron microscopy measurements. The chemical thermodynamics process is discussed. The whole reaction can be separated into four steps. The carburizing of SiO is the key step of whole reaction. The main reaction-sequence is figured out based on Gibbs free energy and equilibrium constant. Flowing Ar is necessary to continue the progress of whole reaction by means of carrying out accumulating gaseous resultants. The film is very useful for application in a variety of MOS-based devices for its silica/SiC/Si(111) structure, in which the silica layer can be removed thoroughly by the standard RCA cleaning process.展开更多
This paper focuses on the heat transfer performance of semi-open heat pipe which is a new type of heat pipe. After analyzing its condensation heat transfer mechanisms theoretically, several semi-open heat pipes in dif...This paper focuses on the heat transfer performance of semi-open heat pipe which is a new type of heat pipe. After analyzing its condensation heat transfer mechanisms theoretically, several semi-open heat pipes in different length ratios and upper hole diameters are studied experimentally and compared with the same dimensions closed heat pipes. Experimental results show that the heat transfer performance of semi-open heat pipe becomes better by increasing heat transfer rate. At the first transitional point, the heat transfer performance of semi-open heat pipe approaches the level of the closed heat pipe. It is suitable to choose upper small hole about 1 mm in diameter and length ratio larger than 0.6 for the semi-open heat pipe.展开更多
The paper addresses the system performance of coal-fired power unit with changed auxiliary system or other local heat disturbance. The idea of state space model is imported and the universal formula for the calculatio...The paper addresses the system performance of coal-fired power unit with changed auxiliary system or other local heat disturbance. The idea of state space model is imported and the universal formula for the calculation of system performance output is deduced on the system state equation. Two important vector of system are worked out under linear system assumption and transform. The transfer matrix is the characteristics of system itself and is constant for a similar condition, which greatly facilitates the analysis. The concept of thermal disturbance vector is proposed to construct the thermal disturbance input easily. The method can be helpful for analyzing any thermal disturbance input satisfying the assumption and also for supplementing the correction means of performance test. An example of 600MW power unit is presented to demonstrate its availability.展开更多
基金This work was supported by the National Natural Science Foundation of China (No.50172044).
文摘SiC films were prepared by modified heating polystyrene/silica bilayer method on Si(111) substrate in normal pressure flowing Ar ambient at 1300℃ . The films were investigated by Fourier transform infrared absorption, X-ray diffraction, and scanning electron microscopy measurements. The chemical thermodynamics process is discussed. The whole reaction can be separated into four steps. The carburizing of SiO is the key step of whole reaction. The main reaction-sequence is figured out based on Gibbs free energy and equilibrium constant. Flowing Ar is necessary to continue the progress of whole reaction by means of carrying out accumulating gaseous resultants. The film is very useful for application in a variety of MOS-based devices for its silica/SiC/Si(111) structure, in which the silica layer can be removed thoroughly by the standard RCA cleaning process.
文摘This paper focuses on the heat transfer performance of semi-open heat pipe which is a new type of heat pipe. After analyzing its condensation heat transfer mechanisms theoretically, several semi-open heat pipes in different length ratios and upper hole diameters are studied experimentally and compared with the same dimensions closed heat pipes. Experimental results show that the heat transfer performance of semi-open heat pipe becomes better by increasing heat transfer rate. At the first transitional point, the heat transfer performance of semi-open heat pipe approaches the level of the closed heat pipe. It is suitable to choose upper small hole about 1 mm in diameter and length ratio larger than 0.6 for the semi-open heat pipe.
文摘The paper addresses the system performance of coal-fired power unit with changed auxiliary system or other local heat disturbance. The idea of state space model is imported and the universal formula for the calculation of system performance output is deduced on the system state equation. Two important vector of system are worked out under linear system assumption and transform. The transfer matrix is the characteristics of system itself and is constant for a similar condition, which greatly facilitates the analysis. The concept of thermal disturbance vector is proposed to construct the thermal disturbance input easily. The method can be helpful for analyzing any thermal disturbance input satisfying the assumption and also for supplementing the correction means of performance test. An example of 600MW power unit is presented to demonstrate its availability.