Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe...Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.展开更多
The absorption-compression heat pump (ACHP) has been considered as an effective approach to recover and utilize low-grade heat sources. In the present study, the first and second law thermodynamic analyses of the AC...The absorption-compression heat pump (ACHP) has been considered as an effective approach to recover and utilize low-grade heat sources. In the present study, the first and second law thermodynamic analyses of the ACHP with NH3/H20 as working fluid were performed. Thermodynamic properties of each point and heat transfer rate of each component in the cycle under basic operation conditions were calculated from the first law analysis. Following the second law of thermodynamics, the entropy generation of each component and the total entropy generation of the system were obtained. The effect~ of the heating temperature, heat source temperature, and compression ratio on the coefficient of performance (COP) and the total entropy generation ( STot ) of the system were examined. The results show that the increase in COP corresponds to a decrease in STot, and vice versa; besides, for certain operating conditions, an optimum compression ratio in the NH~/H20 ACHP exists.展开更多
The thermodynamic aspect of a compression type heat pump (HP) is briefly described and special attention is given to investigation of condensing temperature influence on heat pump efficiency in heating mode, express...The thermodynamic aspect of a compression type heat pump (HP) is briefly described and special attention is given to investigation of condensing temperature influence on heat pump efficiency in heating mode, expressed by its coefficient of performance (COP). Heat pumps are usually applied for the purposes of heating and cooling of energy efficient buildings where they have advantages in low-temperature systems, as it is well documented in the paper. The comparison of real thermodynamic processes with thermodynamically most favorable Camot's process is made. The results in the paper show that COP is diminishing with increasing of condensing temperature and also depends on real properties of working fluids. The impact of compressor efficiency for two real working media is also analyzed in the paper. There is significant diminishing of COP with diminishing of compressor efficiency. The intension of the paper is to help better understanding of this very effective and prosperous technology, and to encourage its development, production, and efficient application.展开更多
In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study des...In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element.展开更多
Based on the physical model of capillary pumped loop (CPL) system, the phenomena of pressure oscillation are simplilied and analyzed. From a set of non-linear differential equations, the influence ofsystem parameters ...Based on the physical model of capillary pumped loop (CPL) system, the phenomena of pressure oscillation are simplilied and analyzed. From a set of non-linear differential equations, the influence ofsystem parameters on the performance of the CPL is discussed, including the working temperature(the Set point), loop resistance, vapor volume etc. From the analysis, some measures were taken tohoprove the performance of the loop. Meanwhile, the reason why the deprive of the CPL occurs duringthe operation is given by analyzing the theoretical calculation results.展开更多
This study presents the performance of a new single-stage scroll compressor used for the heat pump drying of thermally sensitive materials over a wide temperature range. The performance of the new compressor was predi...This study presents the performance of a new single-stage scroll compressor used for the heat pump drying of thermally sensitive materials over a wide temperature range. The performance of the new compressor was predicted by an ARI standard 540 map-based compressor model and verified by a semi-open drying heat pump system constructed for this purpose. A comparison of the experimental data with the predicted data proved that the new scroll compressor used in the drying heat pump works well, can supply a wide range of condensing temperatures (30--80℃) (without auxiliary heating), and has a minimum coeffi- cient of performance (COP) above 2.0, even in the worst condition.展开更多
基金Supported by Major State Basic Research Development Program of China ("973" Program, No. 2009CB219907)the Program for Changjiang Scholars and Innovative Research Team in University (No. IRT0936)
文摘Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.
基金National Key Technologies R&D Program of China(No. 2012BABZ︱2B01)National Natural Science Foundation of China(No. 51106161)Innovation Foundation of President of Guangzhou Institute of Energy Conversion,Chinese Academy of Sciences(No. 0907r7)
文摘The absorption-compression heat pump (ACHP) has been considered as an effective approach to recover and utilize low-grade heat sources. In the present study, the first and second law thermodynamic analyses of the ACHP with NH3/H20 as working fluid were performed. Thermodynamic properties of each point and heat transfer rate of each component in the cycle under basic operation conditions were calculated from the first law analysis. Following the second law of thermodynamics, the entropy generation of each component and the total entropy generation of the system were obtained. The effect~ of the heating temperature, heat source temperature, and compression ratio on the coefficient of performance (COP) and the total entropy generation ( STot ) of the system were examined. The results show that the increase in COP corresponds to a decrease in STot, and vice versa; besides, for certain operating conditions, an optimum compression ratio in the NH~/H20 ACHP exists.
文摘The thermodynamic aspect of a compression type heat pump (HP) is briefly described and special attention is given to investigation of condensing temperature influence on heat pump efficiency in heating mode, expressed by its coefficient of performance (COP). Heat pumps are usually applied for the purposes of heating and cooling of energy efficient buildings where they have advantages in low-temperature systems, as it is well documented in the paper. The comparison of real thermodynamic processes with thermodynamically most favorable Camot's process is made. The results in the paper show that COP is diminishing with increasing of condensing temperature and also depends on real properties of working fluids. The impact of compressor efficiency for two real working media is also analyzed in the paper. There is significant diminishing of COP with diminishing of compressor efficiency. The intension of the paper is to help better understanding of this very effective and prosperous technology, and to encourage its development, production, and efficient application.
文摘In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element.
文摘Based on the physical model of capillary pumped loop (CPL) system, the phenomena of pressure oscillation are simplilied and analyzed. From a set of non-linear differential equations, the influence ofsystem parameters on the performance of the CPL is discussed, including the working temperature(the Set point), loop resistance, vapor volume etc. From the analysis, some measures were taken tohoprove the performance of the loop. Meanwhile, the reason why the deprive of the CPL occurs duringthe operation is given by analyzing the theoretical calculation results.
基金supported by the National High Technology Research and Development Program of China(Grant No.2012AA10A510)
文摘This study presents the performance of a new single-stage scroll compressor used for the heat pump drying of thermally sensitive materials over a wide temperature range. The performance of the new compressor was predicted by an ARI standard 540 map-based compressor model and verified by a semi-open drying heat pump system constructed for this purpose. A comparison of the experimental data with the predicted data proved that the new scroll compressor used in the drying heat pump works well, can supply a wide range of condensing temperatures (30--80℃) (without auxiliary heating), and has a minimum coeffi- cient of performance (COP) above 2.0, even in the worst condition.