Desulfurization experiments of CuO, γ-Al2O3 and CuO/γ-Al2O3 were made in simulated flue gas by means of thermogravimetric analysis. It is found that reaction activities of CuO supported on γ-Al2O3 could be highly i...Desulfurization experiments of CuO, γ-Al2O3 and CuO/γ-Al2O3 were made in simulated flue gas by means of thermogravimetric analysis. It is found that reaction activities of CuO supported on γ-Al2O3 could be highly improved. Desulfurization kinetics of CuO/γ-Al2O3 was studied in the temperature range of 250 °C-400 °C and SO2 concentration of 0.1%-0.9%. The experimental data were tested and compared with kinetics models of volume reaction model(VRM), grain size model(GSM), random pore model(RPM) and pore-blocking model(PBM). Correlation analysis shows that VRM and RPM models do not fit experimental data well. GSM contradicts with the changes in the physical and chemical properties of Cu O/γ-Al2O3 as the desulfurization proceeds. It is found that PBM is consistent with the change of pore structure of CuO/γ-Al2O3 sorbent during desulfurization process and predicts the conversion-time curves of the sorbent well. Meanwhile, kinetics parameters are obtained and discussed.展开更多
A mobile in-situ testing equipment used to detect geotechnical thermophysical properties was developed. The equipment is composed of a heat pump, frequency pumps, an electric tee joint regulator valve, some sensors, a...A mobile in-situ testing equipment used to detect geotechnical thermophysical properties was developed. The equipment is composed of a heat pump, frequency pumps, an electric tee joint regulator valve, some sensors, an electric control system, data acquisition and control system, which can do tests under the condition of extracting and storing subsurface heat. Applying the line source and the cylinder source heat transfer model, and combining the parameters estimation, the average thermophysieal property parameters of rock and soil will be calculated, which provides the basis for designing the ground source heat pump systems.展开更多
Within the OECD/NEA Benchmarking of Thermal-Hydraulic Loop Models for Lead-Alloy Cooled Advanced Nuclear Energy Systems (LACANES), the Institute for Neutron Physics and Reactor Technology takes part in the validatio...Within the OECD/NEA Benchmarking of Thermal-Hydraulic Loop Models for Lead-Alloy Cooled Advanced Nuclear Energy Systems (LACANES), the Institute for Neutron Physics and Reactor Technology takes part in the validation process of system codes and the characterization of the thermal-hydraulic behavior of an experimental loop operated with liquid lead-bismuth-eutectics. To confirm the calculations, the results were compared to experimental data obtained from the HELIOS facility at the Seoul National University and to the results of other benchmark participants. The comparison showed that the calculations are within measurement tolerance but nevertheless discrepancies among the participants exist. The pressure drop estimation is determined by a variety of empirical correlations for the friction and the form loss coefficients. Hence, uncertainty and sensitivity measures were applied to find out which parameter is more relevant for the overall pressure drop. In the frame of this investigation, the system code TRACE and the software system for uncertainty and sensitivity, SUSA, were used. The results show that the total pressure drop varies between -30 and +15% related to the reference case.展开更多
The theoretical analysis discussed in this work is a suitable mathematical tool by which the performance of the proposed collector can be predicted. The obtained experimental results coincide with the obtained theoret...The theoretical analysis discussed in this work is a suitable mathematical tool by which the performance of the proposed collector can be predicted. The obtained experimental results coincide with the obtained theoretical data obtained from the devised computer program. Controlled output temperature can be obtained from the proposed system. The performance of the tested collector under the proposed intermittent flow conditions overcomes that of the conventional thermosyphone flow collector.展开更多
The experimental study was performed on five eccentric radial heat pipes with two outer-tube diameters.The test range can be given as follows,working fluid filling ratio Ω=44%~83%,heat flux q=10000W/m2~32000W/m2,an...The experimental study was performed on five eccentric radial heat pipes with two outer-tube diameters.The test range can be given as follows,working fluid filling ratio Ω=44%~83%,heat flux q=10000W/m2~32000W/m2,and working temperature tv=50 ℃~120 ℃.The correlations between radial heat pipe heat transfer performance and filling ratio,heat flux,working temperature were studied in the experiment.Based on linear regression of experimental data,the relationship between heat pipe equivalent heat resistance R and working temperature tv,heat flux q and filling ratio Ω was obtained.展开更多
基金Projects(51264023,51364020,U1202271)supported by the National Natural Science Foundation of ChinaProject(IRT1250)supported by the Program for Innovative Research Team in University of Ministry of Education of ChinaProject(2014HA003)supported by the Yunnan Province Science and Technology Talents Program,China
文摘Desulfurization experiments of CuO, γ-Al2O3 and CuO/γ-Al2O3 were made in simulated flue gas by means of thermogravimetric analysis. It is found that reaction activities of CuO supported on γ-Al2O3 could be highly improved. Desulfurization kinetics of CuO/γ-Al2O3 was studied in the temperature range of 250 °C-400 °C and SO2 concentration of 0.1%-0.9%. The experimental data were tested and compared with kinetics models of volume reaction model(VRM), grain size model(GSM), random pore model(RPM) and pore-blocking model(PBM). Correlation analysis shows that VRM and RPM models do not fit experimental data well. GSM contradicts with the changes in the physical and chemical properties of Cu O/γ-Al2O3 as the desulfurization proceeds. It is found that PBM is consistent with the change of pore structure of CuO/γ-Al2O3 sorbent during desulfurization process and predicts the conversion-time curves of the sorbent well. Meanwhile, kinetics parameters are obtained and discussed.
基金Supported by Special Project of Public Sector Funding for Scientific Research,Ministry of Land and Resources,China(No.200811066)
文摘A mobile in-situ testing equipment used to detect geotechnical thermophysical properties was developed. The equipment is composed of a heat pump, frequency pumps, an electric tee joint regulator valve, some sensors, an electric control system, data acquisition and control system, which can do tests under the condition of extracting and storing subsurface heat. Applying the line source and the cylinder source heat transfer model, and combining the parameters estimation, the average thermophysieal property parameters of rock and soil will be calculated, which provides the basis for designing the ground source heat pump systems.
文摘Within the OECD/NEA Benchmarking of Thermal-Hydraulic Loop Models for Lead-Alloy Cooled Advanced Nuclear Energy Systems (LACANES), the Institute for Neutron Physics and Reactor Technology takes part in the validation process of system codes and the characterization of the thermal-hydraulic behavior of an experimental loop operated with liquid lead-bismuth-eutectics. To confirm the calculations, the results were compared to experimental data obtained from the HELIOS facility at the Seoul National University and to the results of other benchmark participants. The comparison showed that the calculations are within measurement tolerance but nevertheless discrepancies among the participants exist. The pressure drop estimation is determined by a variety of empirical correlations for the friction and the form loss coefficients. Hence, uncertainty and sensitivity measures were applied to find out which parameter is more relevant for the overall pressure drop. In the frame of this investigation, the system code TRACE and the software system for uncertainty and sensitivity, SUSA, were used. The results show that the total pressure drop varies between -30 and +15% related to the reference case.
文摘The theoretical analysis discussed in this work is a suitable mathematical tool by which the performance of the proposed collector can be predicted. The obtained experimental results coincide with the obtained theoretical data obtained from the devised computer program. Controlled output temperature can be obtained from the proposed system. The performance of the tested collector under the proposed intermittent flow conditions overcomes that of the conventional thermosyphone flow collector.
文摘The experimental study was performed on five eccentric radial heat pipes with two outer-tube diameters.The test range can be given as follows,working fluid filling ratio Ω=44%~83%,heat flux q=10000W/m2~32000W/m2,and working temperature tv=50 ℃~120 ℃.The correlations between radial heat pipe heat transfer performance and filling ratio,heat flux,working temperature were studied in the experiment.Based on linear regression of experimental data,the relationship between heat pipe equivalent heat resistance R and working temperature tv,heat flux q and filling ratio Ω was obtained.