期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
我厂700t/d预分解窑热工监控系统的改造
1
作者 包山先 赵辉 《水泥工程》 CAS 2001年第1期36-37,共2页
关键词 水泥 熟料 预分解窑 热工监控系统
下载PDF
基于RS485总线的水泥回转窑热工智能监控系统的设计 被引量:1
2
作者 余张国 李众立 +2 位作者 黄玉清 李磊民 张崇 《西南科技大学学报》 CAS 2003年第3期6-9,共4页
阐述了干法水泥生产的热工系统的工艺流程 ,并在此基础上阐述了基于串行总线、远端智能模块、工业组态软件、多屏幕动态显示的水泥回转窑热工监控系统的设计与实现方法。
关键词 RS485总线 水泥回转窑 智能监控系统 系统设计 智能模块 组态软件
下载PDF
Analog-experiment analysis of ash-deposition monitoring model of boiler economizers in power plants
3
作者 程伟良 夏国栋 徐寿臣 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2005年第6期680-683,共4页
Ash deposition is a form of particulate fouling, and appears usually in boiler economizers. The ash deposition increases capital expenditure, energy input and maintenance costs. An analog experiment for monitoring ash... Ash deposition is a form of particulate fouling, and appears usually in boiler economizers. The ash deposition increases capital expenditure, energy input and maintenance costs. An analog experiment for monitoring ash deposition was performed from the analogous objective of a 410 t/h boiler economizer to verify the rationality and reliability of the ash-deposition-monitoring model presented in order to increase the security and economy in economizer running. The analog experiment platform is a tube-shell exchanger that conforms well to the conditions of a self-modeling area. The analog flue gas in the shell side is the heated air mixed with ash, and in the tube side the fluid is water heated by the flue gas. The fluid state in the water side and the flue gas side follows the second self-modeling area. A 4-factor-3-level orthogonal table was used to schedule 9 operation conditions of orthogonal experiment, with the 4 factors being heat power, flue gas velocity, ashes grain diameter and adding ashes quantity while the three levels are different values due to different position classes in every factor. The ash deposition thermal resistances is calculated by the model with the measure parameters of temperature and pressure drop. It shows that the values of the ash deposition thermal resistances gradually increase up to a stable state. And the experimental results are reliable by F testing method at α= 0.001. Therefore, the model can be applied in online monitoring of ash deposition in a boiler economizers in power plants and provides scientific decision on ash deposition prediction and sootblowing. 展开更多
关键词 thermal power engineering monitoring model ash deposition orthogonal experiment boiler economizer tube-shell exchanger
下载PDF
分布式控制系统在锅炉燃烧控制中的应用
4
作者 张丽波 乔焰辉 肖敏 《吉林勘察设计》 2005年第1期53-56,共4页
介绍了HIC-1000分布式控制系统的硬件组成、软件体系、技术特点及其在某热电厂#2炉上的应用情况。实际测试和运行表明,HIC-1000分布式控制系统运行可靠、自动投入率高、控制系统性能指标良好、经济效益明显。
关键词 分散控制系统 电站锅炉 热工监控系统
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部