The thermal engineering research has been executed for the threecircuit heat exchanger of a coiled type, that provides the thermal loads regulation for the heating and hot water supply systems. A processing curve of t...The thermal engineering research has been executed for the threecircuit heat exchanger of a coiled type, that provides the thermal loads regulation for the heating and hot water supply systems. A processing curve of the warmth supply regulation at a combined heating and hot water supply load, was used at that. It is important to know the processes running inside the apparatus for the technical characteristics improvement of the threecircuit heat exchanger of a coiled type. The task solution will allow save the materials consumption for the threecircuit heat exchangers of a coiled type manufacturing in the future.展开更多
Gross pollutants are the primary targeted pollutants in urban catchment management for urban water quality improvement as well as mitigation of flood. Apart from aesthetically unattractive because of its visibility, g...Gross pollutants are the primary targeted pollutants in urban catchment management for urban water quality improvement as well as mitigation of flood. Apart from aesthetically unattractive because of its visibility, gross pollutants also contributes to degradation of river water quality and loss of aquatic habitat as it carries harmful pollutants such as oxygen demanding material, hydrocarbons and heavy metals. This study analyzed trend of gross pollutant generated from two urban residential areas located in Selangor, Malaysia. The median value of gross pollutant load obtained fi'om the Amanah Apartment and Bandar Botanic are 347.41 kg/ha/year and 32.46 kg/ha/year, respectively. Relationship between gross pollutant wet load with rainfall depths was derived using regression equation. A significant trend of increasing gross pollutant wet load into drainage system with increasing rainfall depth was observed. The behavior of pollutant load is related to the one observed in Australia.展开更多
文摘The thermal engineering research has been executed for the threecircuit heat exchanger of a coiled type, that provides the thermal loads regulation for the heating and hot water supply systems. A processing curve of the warmth supply regulation at a combined heating and hot water supply load, was used at that. It is important to know the processes running inside the apparatus for the technical characteristics improvement of the threecircuit heat exchanger of a coiled type. The task solution will allow save the materials consumption for the threecircuit heat exchangers of a coiled type manufacturing in the future.
文摘Gross pollutants are the primary targeted pollutants in urban catchment management for urban water quality improvement as well as mitigation of flood. Apart from aesthetically unattractive because of its visibility, gross pollutants also contributes to degradation of river water quality and loss of aquatic habitat as it carries harmful pollutants such as oxygen demanding material, hydrocarbons and heavy metals. This study analyzed trend of gross pollutant generated from two urban residential areas located in Selangor, Malaysia. The median value of gross pollutant load obtained fi'om the Amanah Apartment and Bandar Botanic are 347.41 kg/ha/year and 32.46 kg/ha/year, respectively. Relationship between gross pollutant wet load with rainfall depths was derived using regression equation. A significant trend of increasing gross pollutant wet load into drainage system with increasing rainfall depth was observed. The behavior of pollutant load is related to the one observed in Australia.