Subway thermal environment control system is a mass energy consumed system. The fan operation is the Key of energy saving. Some feasible fan operation modes are proposed and compared in this paper from the view of ene...Subway thermal environment control system is a mass energy consumed system. The fan operation is the Key of energy saving. Some feasible fan operation modes are proposed and compared in this paper from the view of energy and operation cost saving. It is concluded that VAV is the optimal operation mode for metro system with highest energy saving.展开更多
The coal fire is one of very serious disasters in natural, not only amount of coal resources was burned and some ecological environment problems such as ground subsidence, acid rain, pollution and vegetation died were...The coal fire is one of very serious disasters in natural, not only amount of coal resources was burned and some ecological environment problems such as ground subsidence, acid rain, pollution and vegetation died were caused serious. The No.4 coal seam outcrops fire in Haibaoqing was take as research object, based on the existing theory of mechanism and characteristics of coal outcrop fires, a new fire-fighting composite gel is applicated which fits in with extinguishment of outcrop coal fires well. The technology has many advantages in extinguishing coal fires including isolating the coal from oxygen and lowering the temperature of the high-temperature coal and rock. The structure and chemical composition as well as fires-fighting properties of the composite gel is analyzed profoundly, as a result, reduce and stop the environment destruction caused by the coal fire.展开更多
This paper presents an overview of the AMS thermal control system and its thermal environment on the ISS.We give examples of analysis and correlation of space environmental impacting on the thermal control system of A...This paper presents an overview of the AMS thermal control system and its thermal environment on the ISS.We give examples of analysis and correlation of space environmental impacting on the thermal control system of AMS.The most critical factors that affect the thermal environment to AMS are beta angle,attitude of ISS,ISS solar array and ISS radiator positions.The design of a special sandwich structure with embedded heat pipes provides the radiator with higher heat transfer ability for electronics and power crates,and it provides a large heat retaining capacity to balance the frequent changes of the space environment temperatures as well.In cold cases,the thermostatically controlled heaters are working actively to protect AMS.However,sometimes,because of ISS special operations plus extreme beta angle condition,AMS needs to request NASA to adjust the ISS configuration for thermal control.The AMS thermal control system is reliable and stable,which has been verified by its operation on the ISS for more than three years.All the detectors operate normally,the electronics and crates work within their specific temperature limits.展开更多
文摘Subway thermal environment control system is a mass energy consumed system. The fan operation is the Key of energy saving. Some feasible fan operation modes are proposed and compared in this paper from the view of energy and operation cost saving. It is concluded that VAV is the optimal operation mode for metro system with highest energy saving.
文摘The coal fire is one of very serious disasters in natural, not only amount of coal resources was burned and some ecological environment problems such as ground subsidence, acid rain, pollution and vegetation died were caused serious. The No.4 coal seam outcrops fire in Haibaoqing was take as research object, based on the existing theory of mechanism and characteristics of coal outcrop fires, a new fire-fighting composite gel is applicated which fits in with extinguishment of outcrop coal fires well. The technology has many advantages in extinguishing coal fires including isolating the coal from oxygen and lowering the temperature of the high-temperature coal and rock. The structure and chemical composition as well as fires-fighting properties of the composite gel is analyzed profoundly, as a result, reduce and stop the environment destruction caused by the coal fire.
基金supported by the Shandong Province Outstanding Young Scientist Award Fund(Grant No.BS2013NJ026)the National Basic Research Program of China("973"Project)(Grant No.2013CB228305)
文摘This paper presents an overview of the AMS thermal control system and its thermal environment on the ISS.We give examples of analysis and correlation of space environmental impacting on the thermal control system of AMS.The most critical factors that affect the thermal environment to AMS are beta angle,attitude of ISS,ISS solar array and ISS radiator positions.The design of a special sandwich structure with embedded heat pipes provides the radiator with higher heat transfer ability for electronics and power crates,and it provides a large heat retaining capacity to balance the frequent changes of the space environment temperatures as well.In cold cases,the thermostatically controlled heaters are working actively to protect AMS.However,sometimes,because of ISS special operations plus extreme beta angle condition,AMS needs to request NASA to adjust the ISS configuration for thermal control.The AMS thermal control system is reliable and stable,which has been verified by its operation on the ISS for more than three years.All the detectors operate normally,the electronics and crates work within their specific temperature limits.