The present work experimentally and numerically investigates the local heat transfer enhancement induced by a piezoelectric fan interacting with a cross flow in a local heated channel.The piezoelectric fan is placed a...The present work experimentally and numerically investigates the local heat transfer enhancement induced by a piezoelectric fan interacting with a cross flow in a local heated channel.The piezoelectric fan is placed along the flow direction and tested under different amplitudes and flow rates.In the simulations,a spring-based smoothing method and a local remeshing technique are used to handle the moving boundary problems.Hybrid mesh is used to reduce the size of dynamic mesh domain and to improve computational efficiency.The experimental and numerical values of the time-averaged mean Nusselt number are found to be in good agreement,with deviations of less than 10%.The experimental result shows that the heat transfer performance of the heated surfaces is substantially enhanced with a vibrating piezoelectric fan.The numerical result shows that the heat transfer enhancement comes from the strong longitudinal vortex pairs generated by the piezoelectric fan,which significantly promote heat exchange between the main flow and the near-wall flow.In the case of a=0.66(a is the dimensionless amplitude)and Re=1820,the enhancement ratio of the time-averaged mean Nusselt number reaches 119.9%.展开更多
The power transformer is the most important equipment of the high voltage power grid, however, some traditional methods of online partial discharge monitoring have some limitations. Based on many advantages of the opt...The power transformer is the most important equipment of the high voltage power grid, however, some traditional methods of online partial discharge monitoring have some limitations. Based on many advantages of the optical fiber sensing technology, we have done some research on fiber optics Fabry-Perot (FP) sensing which can be useful for the transformer on online partial discharge monitoring. This research aimed at improving the reliability of power system safety monitoring. We have done some work as follows: designing a set for fiber optics FP sensor preparation, according to the fabrication procedure strictly making out the sensors, building a reasonable signal demodulation system for fiber optics FP sensing, doing a preliminary analysis about online partial discharge signal monitoring, including the research on different discharge intensities with the same measuring distance and different measuring distances with the same discharge intensity, and then making a detailed analysis of the experimental results.展开更多
基金Project supported by the National Natural Science Foundation of China(Nos.51575487 , 51875521)。
文摘The present work experimentally and numerically investigates the local heat transfer enhancement induced by a piezoelectric fan interacting with a cross flow in a local heated channel.The piezoelectric fan is placed along the flow direction and tested under different amplitudes and flow rates.In the simulations,a spring-based smoothing method and a local remeshing technique are used to handle the moving boundary problems.Hybrid mesh is used to reduce the size of dynamic mesh domain and to improve computational efficiency.The experimental and numerical values of the time-averaged mean Nusselt number are found to be in good agreement,with deviations of less than 10%.The experimental result shows that the heat transfer performance of the heated surfaces is substantially enhanced with a vibrating piezoelectric fan.The numerical result shows that the heat transfer enhancement comes from the strong longitudinal vortex pairs generated by the piezoelectric fan,which significantly promote heat exchange between the main flow and the near-wall flow.In the case of a=0.66(a is the dimensionless amplitude)and Re=1820,the enhancement ratio of the time-averaged mean Nusselt number reaches 119.9%.
基金This work was supported by the National Natural Science Foundation of China (Grant No. 51275373) and the Key Project of National Natural Science Foundation of China (Grant No. 50830230).
文摘The power transformer is the most important equipment of the high voltage power grid, however, some traditional methods of online partial discharge monitoring have some limitations. Based on many advantages of the optical fiber sensing technology, we have done some research on fiber optics Fabry-Perot (FP) sensing which can be useful for the transformer on online partial discharge monitoring. This research aimed at improving the reliability of power system safety monitoring. We have done some work as follows: designing a set for fiber optics FP sensor preparation, according to the fabrication procedure strictly making out the sensors, building a reasonable signal demodulation system for fiber optics FP sensing, doing a preliminary analysis about online partial discharge signal monitoring, including the research on different discharge intensities with the same measuring distance and different measuring distances with the same discharge intensity, and then making a detailed analysis of the experimental results.