A mobile in-situ testing equipment used to detect geotechnical thermophysical properties was developed. The equipment is composed of a heat pump, frequency pumps, an electric tee joint regulator valve, some sensors, a...A mobile in-situ testing equipment used to detect geotechnical thermophysical properties was developed. The equipment is composed of a heat pump, frequency pumps, an electric tee joint regulator valve, some sensors, an electric control system, data acquisition and control system, which can do tests under the condition of extracting and storing subsurface heat. Applying the line source and the cylinder source heat transfer model, and combining the parameters estimation, the average thermophysieal property parameters of rock and soil will be calculated, which provides the basis for designing the ground source heat pump systems.展开更多
Though TES (thermal energy storage) is developed hugely in most of the solar power generation plants, it is less growth in implementing a modular type of TES in a solar plant, e.g., solar dish/stifling engine applic...Though TES (thermal energy storage) is developed hugely in most of the solar power generation plants, it is less growth in implementing a modular type of TES in a solar plant, e.g., solar dish/stifling engine application. The main issue in designing the TES system is its thermal capacity of storage materials, e.g., insulator. This study is focusing on the potential waste material as an insulator for thermal energy storage applications. The insulator usage is to reduce the heat transfer between two mediums and the capability is measured by its resistance to heat flow. It is needed to obtain optimal materials to energy conversion at the same time reduce the waste generation. Therefore, a small-scale experimental testing of natural cooling process of an insulated tank within a confined room without any forced cooling system, e.g., fan. The testing is repeated by changing the insulator using the potential waste material from natural and industrial waste and also by changing the HTF (heat transfer fluid). The analysis is performed on the relationship between heat loss and the reserved period by the insulator. The results indicate the percentage of period of the insulated tank withstands the heat compared to non-insulated tank, e.g., cotton reserved the period of 14% more than non-insulated tank to withstand the heat transfer of cooking oil to the surrounding. The paper finally justifies the most potential waste material as an insulator in different heat transfer fluids.展开更多
In 2006, the following work on secondary heating systems for HL-2A tokamak have been done: the development of an electron cyclotron resonance heating (ECRH) system, the improvement of lower hybrid resonance heating...In 2006, the following work on secondary heating systems for HL-2A tokamak have been done: the development of an electron cyclotron resonance heating (ECRH) system, the improvement of lower hybrid resonance heating (LHCD) system and the fabrication on neutral beam injection (NBI) system.展开更多
The financial viability of a solar STES (seasonal thermal energy store) installed in a mixed commercial and residential multiunit development of low-energy buildings located in Lysekil, Sweden, a maritime Scandinavi...The financial viability of a solar STES (seasonal thermal energy store) installed in a mixed commercial and residential multiunit development of low-energy buildings located in Lysekil, Sweden, a maritime Scandinavian Climate has been investigated. Using recorded figures for the installation costs and performance, a financial life cycle analysis has been undertaken to determine the cost effectiveness of the system. The time value of money is considered and an LCC (life cycle cost) analysis undertaken to identify the cost-effectiveness of the solution. It shows that while a direct heating and hot water system incorporating STES can be economically viable in a Swedish maritime climate in the long term, assistance such as that provided by government incentives is required to assist with the high capital cost of the initial investment.展开更多
基金Supported by Special Project of Public Sector Funding for Scientific Research,Ministry of Land and Resources,China(No.200811066)
文摘A mobile in-situ testing equipment used to detect geotechnical thermophysical properties was developed. The equipment is composed of a heat pump, frequency pumps, an electric tee joint regulator valve, some sensors, an electric control system, data acquisition and control system, which can do tests under the condition of extracting and storing subsurface heat. Applying the line source and the cylinder source heat transfer model, and combining the parameters estimation, the average thermophysieal property parameters of rock and soil will be calculated, which provides the basis for designing the ground source heat pump systems.
文摘Though TES (thermal energy storage) is developed hugely in most of the solar power generation plants, it is less growth in implementing a modular type of TES in a solar plant, e.g., solar dish/stifling engine application. The main issue in designing the TES system is its thermal capacity of storage materials, e.g., insulator. This study is focusing on the potential waste material as an insulator for thermal energy storage applications. The insulator usage is to reduce the heat transfer between two mediums and the capability is measured by its resistance to heat flow. It is needed to obtain optimal materials to energy conversion at the same time reduce the waste generation. Therefore, a small-scale experimental testing of natural cooling process of an insulated tank within a confined room without any forced cooling system, e.g., fan. The testing is repeated by changing the insulator using the potential waste material from natural and industrial waste and also by changing the HTF (heat transfer fluid). The analysis is performed on the relationship between heat loss and the reserved period by the insulator. The results indicate the percentage of period of the insulated tank withstands the heat compared to non-insulated tank, e.g., cotton reserved the period of 14% more than non-insulated tank to withstand the heat transfer of cooking oil to the surrounding. The paper finally justifies the most potential waste material as an insulator in different heat transfer fluids.
文摘In 2006, the following work on secondary heating systems for HL-2A tokamak have been done: the development of an electron cyclotron resonance heating (ECRH) system, the improvement of lower hybrid resonance heating (LHCD) system and the fabrication on neutral beam injection (NBI) system.
文摘The financial viability of a solar STES (seasonal thermal energy store) installed in a mixed commercial and residential multiunit development of low-energy buildings located in Lysekil, Sweden, a maritime Scandinavian Climate has been investigated. Using recorded figures for the installation costs and performance, a financial life cycle analysis has been undertaken to determine the cost effectiveness of the system. The time value of money is considered and an LCC (life cycle cost) analysis undertaken to identify the cost-effectiveness of the solution. It shows that while a direct heating and hot water system incorporating STES can be economically viable in a Swedish maritime climate in the long term, assistance such as that provided by government incentives is required to assist with the high capital cost of the initial investment.