The location, intensity and scope of concentrated leakage must be determined in order to repair earth-Dam scoured by the leakage. In this paper, firstly, heat tracer theory and distribution laws of temperature in soil...The location, intensity and scope of concentrated leakage must be determined in order to repair earth-Dam scoured by the leakage. In this paper, firstly, heat tracer theory and distribution laws of temperature in soil body with leakage are discussed. Then temperature tracer model is established according to stable heat conduction theory. In such model, the concentrated seepage passage is simplified into a circular pipe as a boundary condition. The location, scope and flow-velocity of the concentrated leakage are estimated via ichnography of the lowest temperature based on temperature data from detecting wells by quantitative computation and qualitative analysis. In case study, the distribution characteristic of temperature (including temperature data of water in reservoir, drainage pipes and tail pond) can be interpreted by this model. A modified model is also set up, applied for detected data at different cross-sections of the leakage passage, in which the temperature data are rectified according to distances from data locations to calculating section. Finally, the model is solved by numerical iterative method, and the possible error of this theoretical model is discussed. The permeability coefficient in leakage area is identical with that of normal soil in magnitude after anti-seepage repairing accomplished, which indicates this model is effective.展开更多
In order to investigate the temperature distribution, a three-dimensional finite element model (FEM) was developed to simulate the temperature regime in the channels of double-loop inductor, and the simulated result...In order to investigate the temperature distribution, a three-dimensional finite element model (FEM) was developed to simulate the temperature regime in the channels of double-loop inductor, and the simulated results were compared with experimental data from low load trials of a 400 kW inductor. The results of numerical simulations, such as the temperature and Joule heating rate, show reasonable correlation with experimental data. The results indicate that Joule heating rate and the temperature reach the maximum at the comers and the minimum at the centre of the cross-section area. The temperature difference between the inlet and outlet is in an inverse proportion to mass transport. Joule heating rate and the temperature are directly proportional to power frequency. It is concluded that mass transport and power frequency play a critical role in determining the temperature regime and Joule heating rate, the relative permeability of the magnetic core shows no significant influence on temperature regime and Joule heating rate, when the relative permeability varies from 5 000 to 10 000.展开更多
基金Financial support from the National Nature Science Foundation of China(50179009)National Nature Science Foundation of China for important project(50139030)
文摘The location, intensity and scope of concentrated leakage must be determined in order to repair earth-Dam scoured by the leakage. In this paper, firstly, heat tracer theory and distribution laws of temperature in soil body with leakage are discussed. Then temperature tracer model is established according to stable heat conduction theory. In such model, the concentrated seepage passage is simplified into a circular pipe as a boundary condition. The location, scope and flow-velocity of the concentrated leakage are estimated via ichnography of the lowest temperature based on temperature data from detecting wells by quantitative computation and qualitative analysis. In case study, the distribution characteristic of temperature (including temperature data of water in reservoir, drainage pipes and tail pond) can be interpreted by this model. A modified model is also set up, applied for detected data at different cross-sections of the leakage passage, in which the temperature data are rectified according to distances from data locations to calculating section. Finally, the model is solved by numerical iterative method, and the possible error of this theoretical model is discussed. The permeability coefficient in leakage area is identical with that of normal soil in magnitude after anti-seepage repairing accomplished, which indicates this model is effective.
基金Project(50876116) supported by the National Natural Science Foundation of ChinaProject(2007CK3077) supported by the Innovative Program of Hunan Science and Technology Agency, ChinaProject(1343-77225) supported by the Graduate School of Central South University, China
文摘In order to investigate the temperature distribution, a three-dimensional finite element model (FEM) was developed to simulate the temperature regime in the channels of double-loop inductor, and the simulated results were compared with experimental data from low load trials of a 400 kW inductor. The results of numerical simulations, such as the temperature and Joule heating rate, show reasonable correlation with experimental data. The results indicate that Joule heating rate and the temperature reach the maximum at the comers and the minimum at the centre of the cross-section area. The temperature difference between the inlet and outlet is in an inverse proportion to mass transport. Joule heating rate and the temperature are directly proportional to power frequency. It is concluded that mass transport and power frequency play a critical role in determining the temperature regime and Joule heating rate, the relative permeability of the magnetic core shows no significant influence on temperature regime and Joule heating rate, when the relative permeability varies from 5 000 to 10 000.