In this paper,the performance of a solar thermal system with a focus on space heating was investigated.A 70 m^(2) detached house was considered in the weather conditions of the city of Tehran,Iran.A thermosyphon solar...In this paper,the performance of a solar thermal system with a focus on space heating was investigated.A 70 m^(2) detached house was considered in the weather conditions of the city of Tehran,Iran.A thermosyphon solar water heater with a flat plate collector combined with an auxiliary electrical heater supplies the heating demand of the house.The proposed system was modeled and analyzed using TRNSYS software.In this regard,the TRNBuild module was employed for the building load calculation.The model has been simulated for one year of operation.The effects of the solar collector’s surface area and storage volume were assessed.The results show that for a solar collector with a 15 m^(2) surface area,the solar fraction is 0.29 in January,during which the solar radiation is the lowest.Using solar collectors of10 m^(2) and 5 m^(2) surface areas,the solar fraction falls to 0.23 and 0.14,respectively in January.Besides,two cases of 150 L and 300 L storage tanks are taken into account.Eventually,it is found that using a 15 m^(2) solar collector and a 150 L storage tank can appropriately provide the building’ s heating demand taking the thermal performance and economic aspects into consideration.展开更多
Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having ...Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having outside air temperature higher than (-3 ℃ to -5 ℃). But, in such conditions the heat pump's evaporator is covered by ice crust, which cuts off the flow of outside air-heat source through the evaporator of heat pump. For avoiding stating problems it is recommended to use as heat source a mixture of waste warm gases. In this article a high efficiency heating-cooling system is developed, consisting of warm gases mixture sourced heat pump, heating boiler operating simultaneously with heat pump and solar air heater. The heating demand of the served house is shared between boiler and heat pump. Instead of outside air the warm gases mixture enters into evaporator of heat pump. A new construction of heat exchanger was developed. The article presents the structure and principle of operation, as well as the method for optimization and design of suggested system. Analysis proved high energy efficiency and cost effectiveness of the new system.展开更多
Submarine hydrothermal vents occur over a wide depth range from a few meters to several thousands of meters. Most existing hydrothermal fluid samplers are focused on deep-sea environments and are not suited for collec...Submarine hydrothermal vents occur over a wide depth range from a few meters to several thousands of meters. Most existing hydrothermal fluid samplers are focused on deep-sea environments and are not suited for collecting shallow-water fluids. In this study, a new gas-tight sampler which can be easily deployed by both submersibles and scuba divers to collect fluid samples from both deep-sea and shallow-water hydrothermal vents is presented. The proposed sampler uses an electric control sampling valve for fluid collection and a system to measure and display the temperature of the hydrothermal fluid while sampling. It is capable of working in manual mode to be controlled via external signals, or in automatic mode to collect a fluid sample according to the temperature. The master-slave architecture of the electronic system makes the sampler flexible in meeting many different deployment requirements. The performance of the sampler has been demonstrated by preliminary field tests at a shallow-water hydrothermal vent site.展开更多
文摘In this paper,the performance of a solar thermal system with a focus on space heating was investigated.A 70 m^(2) detached house was considered in the weather conditions of the city of Tehran,Iran.A thermosyphon solar water heater with a flat plate collector combined with an auxiliary electrical heater supplies the heating demand of the house.The proposed system was modeled and analyzed using TRNSYS software.In this regard,the TRNBuild module was employed for the building load calculation.The model has been simulated for one year of operation.The effects of the solar collector’s surface area and storage volume were assessed.The results show that for a solar collector with a 15 m^(2) surface area,the solar fraction is 0.29 in January,during which the solar radiation is the lowest.Using solar collectors of10 m^(2) and 5 m^(2) surface areas,the solar fraction falls to 0.23 and 0.14,respectively in January.Besides,two cases of 150 L and 300 L storage tanks are taken into account.Eventually,it is found that using a 15 m^(2) solar collector and a 150 L storage tank can appropriately provide the building’ s heating demand taking the thermal performance and economic aspects into consideration.
文摘Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having outside air temperature higher than (-3 ℃ to -5 ℃). But, in such conditions the heat pump's evaporator is covered by ice crust, which cuts off the flow of outside air-heat source through the evaporator of heat pump. For avoiding stating problems it is recommended to use as heat source a mixture of waste warm gases. In this article a high efficiency heating-cooling system is developed, consisting of warm gases mixture sourced heat pump, heating boiler operating simultaneously with heat pump and solar air heater. The heating demand of the served house is shared between boiler and heat pump. Instead of outside air the warm gases mixture enters into evaporator of heat pump. A new construction of heat exchanger was developed. The article presents the structure and principle of operation, as well as the method for optimization and design of suggested system. Analysis proved high energy efficiency and cost effectiveness of the new system.
基金Project supported by the National Natural Science Foundation of China (No. 41106081), and the Science Fund for Creative Research Groups of the National Natural Science Foundation of China (No. 51221004)
文摘Submarine hydrothermal vents occur over a wide depth range from a few meters to several thousands of meters. Most existing hydrothermal fluid samplers are focused on deep-sea environments and are not suited for collecting shallow-water fluids. In this study, a new gas-tight sampler which can be easily deployed by both submersibles and scuba divers to collect fluid samples from both deep-sea and shallow-water hydrothermal vents is presented. The proposed sampler uses an electric control sampling valve for fluid collection and a system to measure and display the temperature of the hydrothermal fluid while sampling. It is capable of working in manual mode to be controlled via external signals, or in automatic mode to collect a fluid sample according to the temperature. The master-slave architecture of the electronic system makes the sampler flexible in meeting many different deployment requirements. The performance of the sampler has been demonstrated by preliminary field tests at a shallow-water hydrothermal vent site.