Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is ap...Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is applied to a 600?MW boiler modeling under different operating conditions of reverse swirl of secondary air. The numerical results achieve reasonable agreement with experimental data. The calculated results of flow field, the pressure distribution, the relative diameter of tangential circle, angular momentum flux in furnace and the velocity distribution index in horizontal gas pass are analyzed in detail. And then the effects of the reverse swirl of secondary air on flue gas imbalance are discussed. Finally a reasonable operating condition of the reverse swirl of secondary air is presented.展开更多
文摘Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is applied to a 600?MW boiler modeling under different operating conditions of reverse swirl of secondary air. The numerical results achieve reasonable agreement with experimental data. The calculated results of flow field, the pressure distribution, the relative diameter of tangential circle, angular momentum flux in furnace and the velocity distribution index in horizontal gas pass are analyzed in detail. And then the effects of the reverse swirl of secondary air on flue gas imbalance are discussed. Finally a reasonable operating condition of the reverse swirl of secondary air is presented.