When designing and selecting burning equipment for low volatile coal fired boilers,the primary concerns are about coal ignition and burnout.The characteristics of ignition and burnout are analyzed for low volatile coa...When designing and selecting burning equipment for low volatile coal fired boilers,the primary concerns are about coal ignition and burnout.The characteristics of ignition and burnout are analyzed for low volatile coal and the technical measures are discussed for enhancing the combustion and burnout.The adaptability of tangential firing,wall firing and double-arch firing for low volatile coal is studied.Based on the statistic analysis for the main design parameters of domestic low volatile coal fired boilers with tangential firing,wall firing or double-arch W flame firing,the thermal performance for various boiler furnaces is recommended.The combustion systems for different types of boilers are also put forward for coals with different volatiles.展开更多
With consideration to the acid gas incinerator burned and the problems identified during its application, renovation program has been proposed. According to the new design, draught burners with automatic control syste...With consideration to the acid gas incinerator burned and the problems identified during its application, renovation program has been proposed. According to the new design, draught burners with automatic control system shall be used to eliminate problems encountered during application of original burner. In addition to implement automatic control of combustion processes, the new system may minimize labor intensity and enhance safety of facilities.展开更多
文摘When designing and selecting burning equipment for low volatile coal fired boilers,the primary concerns are about coal ignition and burnout.The characteristics of ignition and burnout are analyzed for low volatile coal and the technical measures are discussed for enhancing the combustion and burnout.The adaptability of tangential firing,wall firing and double-arch firing for low volatile coal is studied.Based on the statistic analysis for the main design parameters of domestic low volatile coal fired boilers with tangential firing,wall firing or double-arch W flame firing,the thermal performance for various boiler furnaces is recommended.The combustion systems for different types of boilers are also put forward for coals with different volatiles.
文摘With consideration to the acid gas incinerator burned and the problems identified during its application, renovation program has been proposed. According to the new design, draught burners with automatic control system shall be used to eliminate problems encountered during application of original burner. In addition to implement automatic control of combustion processes, the new system may minimize labor intensity and enhance safety of facilities.