A lag correlation analysis is conducted with a 21-day TOGA COARE cloud-resolving model simulation data to identify the phase relation between surface rainfall and convective available potential energy (CAPE) and assoc...A lag correlation analysis is conducted with a 21-day TOGA COARE cloud-resolving model simulation data to identify the phase relation between surface rainfall and convective available potential energy (CAPE) and associated physical processes. The analysis shows that the maximum negative lag correlations between the model domain mean CAPE and rainfall occurs around lag hour 6. The minimum mean CAPE lags mean and convective rainfall through the vapor condensation and depositions,water vapor convergence,and heat divergence whereas it lags stratiform rainfall via the transport of hydrometeor concentration from convective regions to raining stratiform regions,vapor condensation and depositions,water vapor storage,and heat divergence over raining stratiform regions.展开更多
Paper deals about testing of device with gravity assisted heat pipes and about researching of wick heat pipes used to effective heat transfers from power switches of energy converter. At first, to simulate ambient con...Paper deals about testing of device with gravity assisted heat pipes and about researching of wick heat pipes used to effective heat transfers from power switches of energy converter. At first, to simulate ambient condition was designed thermostatic chamber where was monitoring temperature course on main parts of cooling device (energy converter, air cooler and heat pipes) at various position of cooling device. It was found, if the cooling device is in tilt position the cooling performance is better. But if the tilt angel of gravity assisted heat pipe is higher the heat transfer is lower. From reason improve heat transfer cooling device at tilt angle are manufactured heat pipes with the sintered, mesh screen and grooved capillary structures and tested their thermal performance at vertical and tilt angel 45~ position by calorimetric method. Article describes manufacturing process and thermal performance measuring method of wick heat pipes. This experiment testify that the wick heat pipe is able operate at tilt angle position than gravity assisted heat pipe and application of wick heat pipes into cooling device will improve his cooling performance.展开更多
文摘A lag correlation analysis is conducted with a 21-day TOGA COARE cloud-resolving model simulation data to identify the phase relation between surface rainfall and convective available potential energy (CAPE) and associated physical processes. The analysis shows that the maximum negative lag correlations between the model domain mean CAPE and rainfall occurs around lag hour 6. The minimum mean CAPE lags mean and convective rainfall through the vapor condensation and depositions,water vapor convergence,and heat divergence whereas it lags stratiform rainfall via the transport of hydrometeor concentration from convective regions to raining stratiform regions,vapor condensation and depositions,water vapor storage,and heat divergence over raining stratiform regions.
文摘Paper deals about testing of device with gravity assisted heat pipes and about researching of wick heat pipes used to effective heat transfers from power switches of energy converter. At first, to simulate ambient condition was designed thermostatic chamber where was monitoring temperature course on main parts of cooling device (energy converter, air cooler and heat pipes) at various position of cooling device. It was found, if the cooling device is in tilt position the cooling performance is better. But if the tilt angel of gravity assisted heat pipe is higher the heat transfer is lower. From reason improve heat transfer cooling device at tilt angle are manufactured heat pipes with the sintered, mesh screen and grooved capillary structures and tested their thermal performance at vertical and tilt angel 45~ position by calorimetric method. Article describes manufacturing process and thermal performance measuring method of wick heat pipes. This experiment testify that the wick heat pipe is able operate at tilt angle position than gravity assisted heat pipe and application of wick heat pipes into cooling device will improve his cooling performance.