Biomass plants often struggle to capture flow measurements reliably. High amounts of dry solids and fats complicate the measurement with an MID (Magnetic-Inductive) flowmeter and make it susceptible to faults. To ov...Biomass plants often struggle to capture flow measurements reliably. High amounts of dry solids and fats complicate the measurement with an MID (Magnetic-Inductive) flowmeter and make it susceptible to faults. To overcome this impediment, the waste water treatment plant in Innsbruck, Austria, relies on electromagnetic pulsed AC (Alternating Current) flowmeters. Compared to pulsed DC (Direct Current) devices, AC devices are able to build up magnetic fields that are ten times stronger. Equipped with this capability, the Sitrans Transmag 2 is able to guarantee a constant and also high measuring accuracy, zero point stability and signal strength regardless of impurities in the medium or fluctuations in the magnetic field.展开更多
The heat parameters, the thermoanemometric flow-meter (TAF) errors and the experimental characteristics have been defined. The results of experiments were conducted with the help of physically-informational models a...The heat parameters, the thermoanemometric flow-meter (TAF) errors and the experimental characteristics have been defined. The results of experiments were conducted with the help of physically-informational models allowing to realize all major thermal methods and their inherent informative options. The metrological evaluation was made and the sensitivity to the consumption of gas and liquid have been defined, their static and dynamic errors, followed by the comparison of costs according to these criteria. The developed method provides accurate measurement of volumetric flow of motor fuel 1.0-1.5% at heater temperature measurement accuracy of 1%.展开更多
文摘Biomass plants often struggle to capture flow measurements reliably. High amounts of dry solids and fats complicate the measurement with an MID (Magnetic-Inductive) flowmeter and make it susceptible to faults. To overcome this impediment, the waste water treatment plant in Innsbruck, Austria, relies on electromagnetic pulsed AC (Alternating Current) flowmeters. Compared to pulsed DC (Direct Current) devices, AC devices are able to build up magnetic fields that are ten times stronger. Equipped with this capability, the Sitrans Transmag 2 is able to guarantee a constant and also high measuring accuracy, zero point stability and signal strength regardless of impurities in the medium or fluctuations in the magnetic field.
文摘The heat parameters, the thermoanemometric flow-meter (TAF) errors and the experimental characteristics have been defined. The results of experiments were conducted with the help of physically-informational models allowing to realize all major thermal methods and their inherent informative options. The metrological evaluation was made and the sensitivity to the consumption of gas and liquid have been defined, their static and dynamic errors, followed by the comparison of costs according to these criteria. The developed method provides accurate measurement of volumetric flow of motor fuel 1.0-1.5% at heater temperature measurement accuracy of 1%.