The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophagea...The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe with combined axial force and manometry recordings showed that axial force amplitude increased by 130% in contrast to an increase of 30% using manometry. Using axial force in combination with manometry provides a more complete picture of esophageal motility, and the current paper outlines the advantages of using this method.展开更多
Failure analysis of railway draw-hook coupler was carried out.The nondestructive testing method was undertaken on some failed couplers in service to designate critical areas of a coupler.Draw-Hook coupler is used to c...Failure analysis of railway draw-hook coupler was carried out.The nondestructive testing method was undertaken on some failed couplers in service to designate critical areas of a coupler.Draw-Hook coupler is used to connect with the same hook coupler or automatic coupler.The influence of each connection types on the coupler strength in this study was discussed.A numerical stress analysis using FEM was performed,and many approaches including critical plane approach were carried out on fatigue life prediction of coupler under different conditions.The results of the proposed fatigue criterion and fatigue life predictions,as well as static numerical analysis,are validated with experimental results.展开更多
基金Supported by Det Obelske Familiefond and Spar Nord Fonden
文摘The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe with combined axial force and manometry recordings showed that axial force amplitude increased by 130% in contrast to an increase of 30% using manometry. Using axial force in combination with manometry provides a more complete picture of esophageal motility, and the current paper outlines the advantages of using this method.
文摘Failure analysis of railway draw-hook coupler was carried out.The nondestructive testing method was undertaken on some failed couplers in service to designate critical areas of a coupler.Draw-Hook coupler is used to connect with the same hook coupler or automatic coupler.The influence of each connection types on the coupler strength in this study was discussed.A numerical stress analysis using FEM was performed,and many approaches including critical plane approach were carried out on fatigue life prediction of coupler under different conditions.The results of the proposed fatigue criterion and fatigue life predictions,as well as static numerical analysis,are validated with experimental results.