Transcatheter aortic valve implantation (TAV1) represents a real revolution in the field of interventional cardiology for the treatment of elderly or high-risk surgical patients with severe symptomatic aortic valve ...Transcatheter aortic valve implantation (TAV1) represents a real revolution in the field of interventional cardiology for the treatment of elderly or high-risk surgical patients with severe symptomatic aortic valve stenosis. Today, TAVI seems to play a key and a reliable role in the treatment of intermediate and maybe low-risk patients with severe aortic stenosis. TAVI has also evolved from a complex and hazardous procedure into an effective and safe therapy by the development of new generation devices. This article aims to review the background and future of TAVI, elinieal trials and registries with old and new generation TAVI devices and to focus on some open issues related to post-procedural outcomes.展开更多
Objective: To observe the therapeutic effect and safety of using the hooked needle-shaped knife to treat the stenosing tenovaginitis of flexor digitorum. Methods: Sixty outpatients were divided into a treatment group ...Objective: To observe the therapeutic effect and safety of using the hooked needle-shaped knife to treat the stenosing tenovaginitis of flexor digitorum. Methods: Sixty outpatients were divided into a treatment group of 30 cases treated by using the hooked needle shaped knife, and a control group of 30 cases treated by block therapy. 6 months later, the alleviation of pain in the affected finger during movement, under pressure, traction and finger-bending anti-resistance was compared before and after treatment. Results: The alleviation of pain during movement, under pressure, traction and finger-bending anti-resistance was much better in the treatment group than that of the control group (P<0.01), with a effective rate of 93.3% in the treatment group and 80.0% in the control group (P<0.01). Conclusion: The micro-wound technique using the hooked needle-shaped knife has definite effect and safety for stenosing tenovaginitis of flexor digitorum.展开更多
This Communication deals with the blood flow of Prandtl fluid through a tapered stenosed arteries having permeable walls.The governing equations of two-dimensional Prandtl fluid model are modelled in cylindrical coord...This Communication deals with the blood flow of Prandtl fluid through a tapered stenosed arteries having permeable walls.The governing equations of two-dimensional Prandtl fluid model are modelled in cylindrical coordinates.The highly nonlinear equations are simplified with the help of non-dimensional variables under the assumption of mild stenosis.The solution of reduced nonlinear equation subject to boundary condition of porous walls having the effects of Darcy's number and slip parameter are computed analytically with the help of perturbation method.Effects of emerging parameters such as impedance A,slip parameter a,stenosis height 6,magnetic parameter and stress component Srz on velocity are illustrated graphically.The streamlines have also been presented to discuss the trapping bolus discipline.展开更多
In this paper, we have discussed the biomathematical analysis of Sutterby fluid model for blood flow in stenosed tapered arteries. The equations for the Sutterby fluid model are modeled in cylindrical geometry. The eq...In this paper, we have discussed the biomathematical analysis of Sutterby fluid model for blood flow in stenosed tapered arteries. The equations for the Sutterby fluid model are modeled in cylindrical geometry. The equations have been developed for the ease of mild stenosis. Perturbation solutions are attained in terms of small Sutterby fluid parameter β for the velocity, impedance resistance and wall shear stress. Three types of arteries i.e. converging, diverging and non-tapered have been considered for the analysis and discussion. Graphical results have been presented for different parameters of interest. Streamlines have been plotted at the end of the paper.展开更多
文摘Transcatheter aortic valve implantation (TAV1) represents a real revolution in the field of interventional cardiology for the treatment of elderly or high-risk surgical patients with severe symptomatic aortic valve stenosis. Today, TAVI seems to play a key and a reliable role in the treatment of intermediate and maybe low-risk patients with severe aortic stenosis. TAVI has also evolved from a complex and hazardous procedure into an effective and safe therapy by the development of new generation devices. This article aims to review the background and future of TAVI, elinieal trials and registries with old and new generation TAVI devices and to focus on some open issues related to post-procedural outcomes.
文摘Objective: To observe the therapeutic effect and safety of using the hooked needle-shaped knife to treat the stenosing tenovaginitis of flexor digitorum. Methods: Sixty outpatients were divided into a treatment group of 30 cases treated by using the hooked needle shaped knife, and a control group of 30 cases treated by block therapy. 6 months later, the alleviation of pain in the affected finger during movement, under pressure, traction and finger-bending anti-resistance was compared before and after treatment. Results: The alleviation of pain during movement, under pressure, traction and finger-bending anti-resistance was much better in the treatment group than that of the control group (P<0.01), with a effective rate of 93.3% in the treatment group and 80.0% in the control group (P<0.01). Conclusion: The micro-wound technique using the hooked needle-shaped knife has definite effect and safety for stenosing tenovaginitis of flexor digitorum.
文摘This Communication deals with the blood flow of Prandtl fluid through a tapered stenosed arteries having permeable walls.The governing equations of two-dimensional Prandtl fluid model are modelled in cylindrical coordinates.The highly nonlinear equations are simplified with the help of non-dimensional variables under the assumption of mild stenosis.The solution of reduced nonlinear equation subject to boundary condition of porous walls having the effects of Darcy's number and slip parameter are computed analytically with the help of perturbation method.Effects of emerging parameters such as impedance A,slip parameter a,stenosis height 6,magnetic parameter and stress component Srz on velocity are illustrated graphically.The streamlines have also been presented to discuss the trapping bolus discipline.
文摘In this paper, we have discussed the biomathematical analysis of Sutterby fluid model for blood flow in stenosed tapered arteries. The equations for the Sutterby fluid model are modeled in cylindrical geometry. The equations have been developed for the ease of mild stenosis. Perturbation solutions are attained in terms of small Sutterby fluid parameter β for the velocity, impedance resistance and wall shear stress. Three types of arteries i.e. converging, diverging and non-tapered have been considered for the analysis and discussion. Graphical results have been presented for different parameters of interest. Streamlines have been plotted at the end of the paper.