本文研究了两种不同授精方式对长×大二元杂交母猪受胎率、返情率、空怀率及精液用量的影响,通过常规人工授精(AI)与猪子宫颈后人工授精(PCAI)两种方式发现,母猪采用常规AI后,受胎率为91.68%,返情率为4.99%,空怀率为3.33%,精液用量8...本文研究了两种不同授精方式对长×大二元杂交母猪受胎率、返情率、空怀率及精液用量的影响,通过常规人工授精(AI)与猪子宫颈后人工授精(PCAI)两种方式发现,母猪采用常规AI后,受胎率为91.68%,返情率为4.99%,空怀率为3.33%,精液用量80 m L,采用PCAI后,受胎率达96.68%,返情率为1.66%,空怀率1.66%,精液用量40 m L。结果表明,PCAI技术的受胎率比常规AI技术的受胎率高5%,返情率、空怀率和精液用量分别低3.33%,1.66%,50%。展开更多
There are some problems in the vascular prostheses, which influence the health of the patients. This paper aims to the radial compliance of three kinds of vascular prostheses and the pig's carotid based on the dynami...There are some problems in the vascular prostheses, which influence the health of the patients. This paper aims to the radial compliance of three kinds of vascular prostheses and the pig's carotid based on the dynamic-simulated condition. The radial compliance of knitted structure vascular prostheses with crimps ranged from 2.52% to 0.94%/100 mmHg, which was superior to e-FFFE and woven prostheses', ranged from 0.73% to 0.31%/100 mmHg and from 0.81% to 0.22%/100 mmHg. But comparing with the radial compliance of pig's carotid, ranged from 7.21% to 10.04% /100 mmHg, there was a big gap between them. And also the trend of the radial compliance of vascular prostheses was different from the real pig's carotid. There is a lot of work left to improve the radial compliance, not only to change the vascular prostheses' compliance, but also to meet with the real vascular.展开更多
文摘本文研究了两种不同授精方式对长×大二元杂交母猪受胎率、返情率、空怀率及精液用量的影响,通过常规人工授精(AI)与猪子宫颈后人工授精(PCAI)两种方式发现,母猪采用常规AI后,受胎率为91.68%,返情率为4.99%,空怀率为3.33%,精液用量80 m L,采用PCAI后,受胎率达96.68%,返情率为1.66%,空怀率1.66%,精液用量40 m L。结果表明,PCAI技术的受胎率比常规AI技术的受胎率高5%,返情率、空怀率和精液用量分别低3.33%,1.66%,50%。
文摘There are some problems in the vascular prostheses, which influence the health of the patients. This paper aims to the radial compliance of three kinds of vascular prostheses and the pig's carotid based on the dynamic-simulated condition. The radial compliance of knitted structure vascular prostheses with crimps ranged from 2.52% to 0.94%/100 mmHg, which was superior to e-FFFE and woven prostheses', ranged from 0.73% to 0.31%/100 mmHg and from 0.81% to 0.22%/100 mmHg. But comparing with the radial compliance of pig's carotid, ranged from 7.21% to 10.04% /100 mmHg, there was a big gap between them. And also the trend of the radial compliance of vascular prostheses was different from the real pig's carotid. There is a lot of work left to improve the radial compliance, not only to change the vascular prostheses' compliance, but also to meet with the real vascular.