竖罐式和环冷式烧结矿冷却过程的数值模拟 被引量:8
1
作者 沈勋 陈林根 +1 位作者 夏少军 孙丰瑞 《中国科学:技术科学》 EI CSCD 北大核心 2016年第1期36-45,共10页
针对烧结矿冷却的两种基本模式——环冷式和竖罐式,分别建立了环冷机、竖罐内对流换热过程的非稳态模型,并运用场协同理论进行了分析比较.结果表明:在相同的冷却效果下,竖罐式冷却过程传热的场协同数明显大于环冷式,因此可以大大加强热... 针对烧结矿冷却的两种基本模式——环冷式和竖罐式,分别建立了环冷机、竖罐内对流换热过程的非稳态模型,并运用场协同理论进行了分析比较.结果表明:在相同的冷却效果下,竖罐式冷却过程传热的场协同数明显大于环冷式,因此可以大大加强热烧结矿高温显热的回收.同时研究了气料比、料层总高度、料层半径等因素对于竖罐式烧结矿冷却过程场协同数的影响,从节约能耗的角度,指出了在兼顾冷却传热性能、实际生产需求的条件下,应当选择相对较小的气料比,且冷却竖罐应由'瘦高型'向'矮胖型'发展. 展开更多
关键词 环冷式 竖罐式 烧结矿冷却 对流换热 数值模拟 场协同
原文传递
Experimental study on closed-cycle solar adsorption cooling system
2
作者 翟晓强 王如竹 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期320-323,共4页
A closed-cycle solar-powered adsorption cooling system is designed.The system is mainly composed of the evacuated tubular solar collectors with an area of 150 m^2,two adsorption chillers with a rated cooling capacity ... A closed-cycle solar-powered adsorption cooling system is designed.The system is mainly composed of the evacuated tubular solar collectors with an area of 150 m^2,two adsorption chillers with a rated cooling capacity of 15 kW,a cooling tower,fan coils and circulating pumps.The experiments were carried out to study the operating characteristics and the performance of the system.It is found that the operation of the system presents wave characteristics because of low water capacity.The water temperatures of the inlet and the outlet of the solar collector array cyclically swing since the water entering the solar collector array comes directly from the adsorption chillers.Besides,the inlet water temperature of the adsorption chillers varies distinctly.However,the cooling effect of the system is satisfactory.Compared with an open-cycle system,the closed-cycle system has the advantage of a high electric COP(coefficient of performance)because of the reduced use of circulating pumps. 展开更多
关键词 solar energy adsorption cooling closed-cycle
下载PDF
Performance analysis of ammonia-water absorption/compression combined refrigeration cycle 被引量:1
3
作者 鲍帅阳 杜垲 +2 位作者 蔡星辰 牛晓峰 武云龙 《Journal of Southeast University(English Edition)》 EI CAS 2014年第1期60-67,共8页
In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis ... In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis and calculations on two combination ways by adding the compressor in the high-pressure area and in the low-pressure area are conducted respectively.The effects of several factors including the evaporation temperature Te heat-source temperature Th as well as the cooling water temperature Tw on the equivalent heat consumption in compression qCW heat consumption in absorption qG and the system coefficient of performance COP are analyzed under the two combination configurations.The results show that the effect of the equivalent heat consumption in compression on the COP is less than that of the heat consumption in absorption.Besides the compressor set in the high-pressure area uses more energy than that in the low-pressure area. Moreover the compressor in the low-pressure area is superior to that in the high-pressure area with respect to the COP. Under the given intermediate pressure there is an optimum heat-source temperature corresponding to the maximum COP of the AWA/CCR cycle. 展开更多
关键词 AMMONIA-WATER ABSORPTION compression refrigeration combined refrigeration cycle coefficient of performance COP
下载PDF
Thermodynamic Analysis and Comparison on Low Temperature CO_2-NH_3 Cascade Refrigeration Cycle
4
作者 查世彤 马一太 +1 位作者 申江 李敏霞 《Transactions of Tianjin University》 EI CAS 2003年第3期252-255,共4页
This paper is focused on the cascade refrigeration cycle using natural refrigerant CO 2-NH 3. The properties of refrigerants CO 2 and NH 3 are introduced and analyzed.CO 2 has the advantage in low stage of cascade ref... This paper is focused on the cascade refrigeration cycle using natural refrigerant CO 2-NH 3. The properties of refrigerants CO 2 and NH 3 are introduced and analyzed.CO 2 has the advantage in low stage of cascade refrigeration cycle due to its good characteristics and properties. The thermodynamic analysis results of the CO 2-NH 3 cascade refrigeration cycle demonstrates that the cycle has an optimum condensation temperature of low stage and also has an optimum flow rate ratio.By comparing with the R13-R22 and NH 3-NH 3 cascade refrigeration cycles, the mass flow rate ratio of CO 2-NH 3 is larger than those of R13-R22 and NH 3-NH 3, the theoretical COP of CO 2-NH 3 cascade refrigeration cycle is larger than that of the R13-R22 cascade cycle and smaller than that of the NH 3-NH 3 cascade cycle. But the real COP of CO 2-NH 3 cascade cycle will be higher than those of R13-R22 and NH 3-NH 3 because the specific volume of CO 2 at low temperature does not change much and its dynamic viscosity is also small. 展开更多
关键词 CO 2-NH 3 cascade refrigeration cycle thermodynamic analysis
下载PDF
Performance comparison and analysis of a combined power and cooling system based on organic Rankine cycle 被引量:2
5
作者 王志奇 周奇遇 +2 位作者 夏小霞 刘斌 张欣 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第2期353-359,共7页
A novel power and cooling system combined system which coupled organic Rankine cycle(ORC) with vapor compression refrigeration cycle(VCRC) was proposed. R245 fa and butane were selected as the working fluid for the po... A novel power and cooling system combined system which coupled organic Rankine cycle(ORC) with vapor compression refrigeration cycle(VCRC) was proposed. R245 fa and butane were selected as the working fluid for the power and refrigeration cycle, respectively. A performance comparison and analysis for the combined system was presented. The results show that dual-pressure ORC-VCRC system can achieve an increase of 7.1% in thermal efficiency and 6.7% in exergy efficiency than that of basic ORC-VCRC. Intermediate pressure is a key parameter to both net power and exergy efficiency of dual-pressure ORC-VCRC system. Combined system can produce maximum net power and exergy efficiency at 0.85 MPa for intermediate pressure and 2.4 MPa for high pressure, respectively. However, superheated temperature at expander inlet has little impact on the two indicators. It can achieve higher overall COP, net power and exergy efficiency at smaller difference between condensation temperature and evaporation temperature of VCRC. 展开更多
关键词 dual-pressure organic Rankine cycle vapor compression refrigeration waste heat performance analysis
下载PDF
Spring Cold Bias of SST and Minimal Wind Mixing in the Equatorial Pacific Cold Tongue 被引量:1
6
作者 LIN Peng-Fei LIU Hai-Long LI Chao ZHANG Xue-Hong 《Atmospheric and Oceanic Science Letters》 2010年第6期342-346,共5页
The authors investigate the relationship between bias in simulated sea surface temperature (SST) in the equatorial eastern Pacific cold tongue during the boreal spring as simulated by an oceanic general circulation ... The authors investigate the relationship between bias in simulated sea surface temperature (SST) in the equatorial eastern Pacific cold tongue during the boreal spring as simulated by an oceanic general circulation model (OGCM) and minimal wind mixing (MWM) at the surface. The cold bias of simulated SST is the greatest during the boreal spring, at approximately 3℃. A sensi- tivity experiment reducing MWM by one order of magnitude greatly alleviates cold biases, especially in March-April. The decrease in bias is primarily due to weakened vertical mixing, which preserves heat in the uppermost layer and results in warmer simulated SST. The reduction in vertical mixing also leads to a weak westward current in the upper layer, which further contributes to SST warming. These findings imply that there are large uncertainties about simple model parameters such as MWM at the oceanic surface. 展开更多
关键词 cold biases the equatorial Pacific cold tongue the minimal wind mixing
下载PDF
基于分析方法对烧结冷却系统余能利用 被引量:7
7
作者 赵梦然 杜梅芳 +1 位作者 陈时选 张忠孝 《钢铁》 CAS CSCD 北大核心 2018年第7期89-94,共6页
介绍了烧结系统采用的环冷和竖罐式两种冷却工艺流程,通过[火用]计算数学模型对烧结工序各个系统进行了分析,比较了两种冷却模式的余热回收效果,结果表明,竖罐冷却模式能大大提高烧结矿的显热回收率,[火用]效率可达到75.39%,比环冷模式... 介绍了烧结系统采用的环冷和竖罐式两种冷却工艺流程,通过[火用]计算数学模型对烧结工序各个系统进行了分析,比较了两种冷却模式的余热回收效果,结果表明,竖罐冷却模式能大大提高烧结矿的显热回收率,[火用]效率可达到75.39%,比环冷模式[火用]效率提高近20%;竖罐模式出口循环热风温度比环冷模式可提高230℃左右;两种模式回收的余热进入余热锅炉产生蒸汽,竖罐模式的蒸汽产量约为环冷模式的3倍。 展开更多
关键词 环冷式 竖罐式 分析 余热回收
原文传递