期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
煤层气U型水平井钻完井新工艺应用
1
作者 竺彪 《中国石油和化工》 2016年第2期62-63,共2页
本文针对七元煤矿15#煤的复杂的地质条件及储层特征,优选钻井液体系和配方,通过使用无固相钻井液,在长达1099m的易坍塌的水平井眼钻进过程中,保证了井壁的稳定性,并起到良好的储层保护作用,通过改变常规水平井完井思路,采用3-1/2"... 本文针对七元煤矿15#煤的复杂的地质条件及储层特征,优选钻井液体系和配方,通过使用无固相钻井液,在长达1099m的易坍塌的水平井眼钻进过程中,保证了井壁的稳定性,并起到良好的储层保护作用,通过改变常规水平井完井思路,采用3-1/2"玻璃钢与冲管组合完井方式完井,增加了储层流体的流动通道,建立了井眼整体循环通道,在钻完井后期,优化破胶及洗井工艺,排出大量煤粉及泥浆,降低了煤储层伤害,为后期排采产气提供了有利的保障。 展开更多
关键词 无固相钻井液 长水平段 玻璃管管 清水洗井
下载PDF
Experimental Investigation of Defects Inspection for FRP Pipeline based on Single-side NMR
2
作者 YANG Yong LIU Chao +3 位作者 WANG Guan-jun LIAO Guang-zhi TAN Xiao-lin CHEN Kai 《International Journal of Technology Management》 2015年第9期37-39,共3页
The fiberglass reinforced plastic (FRP) pipelines have been used widely in oil-gas gathering and transportation. The defects of FRP pipelines would increase with the extension of service time. However, it is very di... The fiberglass reinforced plastic (FRP) pipelines have been used widely in oil-gas gathering and transportation. The defects of FRP pipelines would increase with the extension of service time. However, it is very difficult to detect the defects of FRP pipelines on-spot quickly. In this paper, a new method detecting defects for FRP pipes has been provided based on the NMR. The proton density distributions have been obtained at different depth of FRP components using single-side NMR. The experimental results show that there is a significant change of proton density distribution at the location of defects. And, these results would be useful for defects inspection of composite material component. 展开更多
关键词 Mobile Single-Side NMR FRP (fiber reinforced plastics) Pipes Defects Non-destructive Testing
下载PDF
Bearing capacity of concrete filled bidirectional FRP tube subjected to axial compression
3
作者 于峰 牛荻涛 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2010年第1期145-148,共4页
External confinement by fiber reinforced polymer (FRP) is an efficient technique to increase the bearing capacity and ductility of concrete. To better study the mechanical behavior of bidirectional FRP confined concre... External confinement by fiber reinforced polymer (FRP) is an efficient technique to increase the bearing capacity and ductility of concrete. To better study the mechanical behavior of bidirectional FRP confined concrete, the yield criterion of bidirectional FRP is presented based on the static equilibrium condition in this paper, and a model for calculating the bearing capacity of bidirectional FRP confined concrete is established. The model can capture the character of bidirectional FRP confined concrete. Effects of the confinement effect coefficient, the unconfined concrete strength and the material properties of FRP on bearing capacity are analyzed. Results show that each parameter has different effects on the bearing capacity of bidirectional FRP confined concrete. 展开更多
关键词 fiber reinforced polymer confined concrete bearing capacity column ultimate equilibrium condition
下载PDF
Performance of U-tube Solar Water Heaters Facing Different Directions
4
作者 Ong Kok-Seng Tong Wei-Li David Cheong 《Journal of Energy and Power Engineering》 2013年第9期1729-1734,共6页
System performance of solar water heaters depends upon collector and storage tank designs, solar radiation intensity and ambient temperature, amongst others. Evacuated glass tube collectors with U-tubes inside are les... System performance of solar water heaters depends upon collector and storage tank designs, solar radiation intensity and ambient temperature, amongst others. Evacuated glass tube collectors with U-tubes inside are less prone to leakages than the all-glass or the heat pipe types. U-tube solar water heaters suspended on walls and balconies could help overcome present day roof space restriction and increasing apartment-style housing. As such, their performance would depend upon its orientation when mounted in a vertical position. This paper reports the results of outdoor tests conducted on natural convection U-tube solar water heaters oriented towards different directions. Long and short term test procedures were employed to allow us to compare their performances as if they were tested simultaneously side-by-side. 展开更多
关键词 Solar water heater evacuated glass tube U-tube collector natural convection long and short term tests directional effects.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部