Medical models, or "phantoms," have been widely used for medical training and for doctor-patient interactions. They are increasingly used for surgical planning, medical computational models, algorithm verification a...Medical models, or "phantoms," have been widely used for medical training and for doctor-patient interactions. They are increasingly used for surgical planning, medical computational models, algorithm verification and validation, and medical devices development. Such new applications demand high-fidelity, patient-specific, tissue-mimicking medical phantoms that can not only closely emulate the geometric structures of human organs, but also possess the properties and functions of the organ structure. With the rapid advancement of three-dimensional (3D) printing and 3D bioprinting technologies, many researchers have explored the use of these additive manufacturing techniques to fabricate functional medical phantoms for various applications. This paper reviews the applications of these 3D printing and 3D bioprinting technologies for the fabrication of functional medical phantoms and bio-structures. This review specifically discusses the state of the art along with new developments and trends in 3D printed functional medical phantoms (i.e., tissue-mimicking medical phantoms, radiologically relevant medical phantoms, and physiological medical phantoms) and 3D bio-printed structures (i.e., hybrid scaffolding materials, convertible scaffolds, and integrated sensors) for regenerated tissues and organs.展开更多
A number of congenital and acquired disorders require esophageal tissue replacement.Various surgical techniques,such as gastric and colonic interposition,are standards of treatment,but frequently complicated by stenos...A number of congenital and acquired disorders require esophageal tissue replacement.Various surgical techniques,such as gastric and colonic interposition,are standards of treatment,but frequently complicated by stenosis and other problems.Regenerative medicine approaches facilitate the use of biological constructs to replace or regenerate normal tissue function.We review the literature of esophageal tissue engineering,discuss its implications,compare the methodologies that have been employed and suggest possible directions for the future.Medline,Embase,the Cochrane Library,National Research Register and ClinicalTrials.gov databases were searched with the following search terms:stem cell and esophagus,esophageal replacement,esophageal tissue engineering,esophageal substitution.Reference lists of papers identified were also examined and experts in this field contacted for further information.All full-text articles in English of all potentially relevant abstracts were reviewed.Tissue engineering has involved acellular scaffolds that were either transplanted with the aim of being repopulated by host cells or seeded prior to transplantation.When acellular scaffolds were used to replace patch and short tubular defects they allowed epithelial and partial muscular migration whereas when employed for long tubular defects the results were poor leading to an increased rate of stenosis and mortality.Stenting has been shown as an effective means to reduce stenotic changes and promote cell migration,whilst omental wrapping to induce vascularization of the construct has an uncertain benefit.Decellularized matrices have been recently suggested as the optimal choice for scaffolds,but smart polymers that will incorporate signalling to promote cell-scaffold interaction may provide a more reproducible and available solution.Results in animal models that have used seeded scaffolds strongly suggest that seeding of both muscle and epithelial cells on scaffolds prior to implantation is a prerequisite for complete esophageal replacement.Novel approaches need to be designed to allow for peristalsis and vascularization in the engineered esophagus.Although esophageal tissue engineering potentially offers a real alternative to conventional treatments for severe esophageal disease,important barriers remain that need to be addressed.展开更多
The stent was a major breakthrough in the treatment of atherosclerotic vascular disease. The permanent vascular implant of a stent, however, changes the intra-stent blood flow hemodynamics. There is a growing consensu...The stent was a major breakthrough in the treatment of atherosclerotic vascular disease. The permanent vascular implant of a stent, however, changes the intra-stent blood flow hemodynamics. There is a growing consensus that the stent implant may change the artery wall shear stress distribution and hence lead to the restenosis process. Computational fluid dynamics (CFD) has been widely used to analyze hemodynamics in stented arteries. In this paper, two CFD models (the axisymmetric model and the 3-D stent model) were developed to investigate the effects of strut geometry and blood rheology on the intra-stent hemodynamics. The velocity profile, flow recirculation, and wall shear stress distribution of various stent strut geometries were studied. Results show strong correlations between the intra-stent hemodynamics and strut geometry. The intra-stent blood flow is very sensitive to the strut height and fillet size. A round strut with a large fillet size shows 36% and 34% reductions in key parameters evaluating the restenosis risk for the axisymmetric model and the 3-D stent model, respectively. This suggests that electrochemical polishing, a surface-improving process during stent manufacturing, strongly influences the hemodynamic behavior in stented arteries and should be controlled precisely in order to achieve the best clinical outcome. Rheological effects on the wall shear stress are minor in both axisymmetric and 3-D stent models for the vessel diameter of 4 mm, with Newtonian flow simulation tending to give more conservative estimates ofrestenosis risk. Therefore, it is reasonable to simulate the blood flow as a Newtonian flow in stented arteries using the simpler axisymmetric model. These findings will provide great insights for stent design optimization for potential restenosis improvement.展开更多
文摘Medical models, or "phantoms," have been widely used for medical training and for doctor-patient interactions. They are increasingly used for surgical planning, medical computational models, algorithm verification and validation, and medical devices development. Such new applications demand high-fidelity, patient-specific, tissue-mimicking medical phantoms that can not only closely emulate the geometric structures of human organs, but also possess the properties and functions of the organ structure. With the rapid advancement of three-dimensional (3D) printing and 3D bioprinting technologies, many researchers have explored the use of these additive manufacturing techniques to fabricate functional medical phantoms for various applications. This paper reviews the applications of these 3D printing and 3D bioprinting technologies for the fabrication of functional medical phantoms and bio-structures. This review specifically discusses the state of the art along with new developments and trends in 3D printed functional medical phantoms (i.e., tissue-mimicking medical phantoms, radiologically relevant medical phantoms, and physiological medical phantoms) and 3D bio-printed structures (i.e., hybrid scaffolding materials, convertible scaffolds, and integrated sensors) for regenerated tissues and organs.
文摘A number of congenital and acquired disorders require esophageal tissue replacement.Various surgical techniques,such as gastric and colonic interposition,are standards of treatment,but frequently complicated by stenosis and other problems.Regenerative medicine approaches facilitate the use of biological constructs to replace or regenerate normal tissue function.We review the literature of esophageal tissue engineering,discuss its implications,compare the methodologies that have been employed and suggest possible directions for the future.Medline,Embase,the Cochrane Library,National Research Register and ClinicalTrials.gov databases were searched with the following search terms:stem cell and esophagus,esophageal replacement,esophageal tissue engineering,esophageal substitution.Reference lists of papers identified were also examined and experts in this field contacted for further information.All full-text articles in English of all potentially relevant abstracts were reviewed.Tissue engineering has involved acellular scaffolds that were either transplanted with the aim of being repopulated by host cells or seeded prior to transplantation.When acellular scaffolds were used to replace patch and short tubular defects they allowed epithelial and partial muscular migration whereas when employed for long tubular defects the results were poor leading to an increased rate of stenosis and mortality.Stenting has been shown as an effective means to reduce stenotic changes and promote cell migration,whilst omental wrapping to induce vascularization of the construct has an uncertain benefit.Decellularized matrices have been recently suggested as the optimal choice for scaffolds,but smart polymers that will incorporate signalling to promote cell-scaffold interaction may provide a more reproducible and available solution.Results in animal models that have used seeded scaffolds strongly suggest that seeding of both muscle and epithelial cells on scaffolds prior to implantation is a prerequisite for complete esophageal replacement.Novel approaches need to be designed to allow for peristalsis and vascularization in the engineered esophagus.Although esophageal tissue engineering potentially offers a real alternative to conventional treatments for severe esophageal disease,important barriers remain that need to be addressed.
文摘The stent was a major breakthrough in the treatment of atherosclerotic vascular disease. The permanent vascular implant of a stent, however, changes the intra-stent blood flow hemodynamics. There is a growing consensus that the stent implant may change the artery wall shear stress distribution and hence lead to the restenosis process. Computational fluid dynamics (CFD) has been widely used to analyze hemodynamics in stented arteries. In this paper, two CFD models (the axisymmetric model and the 3-D stent model) were developed to investigate the effects of strut geometry and blood rheology on the intra-stent hemodynamics. The velocity profile, flow recirculation, and wall shear stress distribution of various stent strut geometries were studied. Results show strong correlations between the intra-stent hemodynamics and strut geometry. The intra-stent blood flow is very sensitive to the strut height and fillet size. A round strut with a large fillet size shows 36% and 34% reductions in key parameters evaluating the restenosis risk for the axisymmetric model and the 3-D stent model, respectively. This suggests that electrochemical polishing, a surface-improving process during stent manufacturing, strongly influences the hemodynamic behavior in stented arteries and should be controlled precisely in order to achieve the best clinical outcome. Rheological effects on the wall shear stress are minor in both axisymmetric and 3-D stent models for the vessel diameter of 4 mm, with Newtonian flow simulation tending to give more conservative estimates ofrestenosis risk. Therefore, it is reasonable to simulate the blood flow as a Newtonian flow in stented arteries using the simpler axisymmetric model. These findings will provide great insights for stent design optimization for potential restenosis improvement.