Leakage currents, tiny currents flowing from an everyday-life appliance through the body to the ground, can cause a non-adequate perception (called electrocutaneous sensation, ECS) or even pain and should be avoided...Leakage currents, tiny currents flowing from an everyday-life appliance through the body to the ground, can cause a non-adequate perception (called electrocutaneous sensation, ECS) or even pain and should be avoided. Safety standards for low-frequency range are based on experimental results of current thresholds of electrocutaneous sensations, which however show a wide range between about 50 pA (rms) and 1000 μA (rms). In order to be able to explain these differences, the perception threshold was measured repeatedly in experiments with test persons under identical experimental setup, but by means of different methods (measuring strategies), namely: direct adjustment, classical threshold as amperage of 50% perception probability, and confidence rating procedure of signal detection theory. The current is injected using a I cm2 electrode at the highly touch sensitive part of the index fingertip. These investigations show for the first time that the threshold of electrocutaneous sensations is influenced both by adaptation to the non-adequate stimulus and individual, emotional factors. Theretbre, classical methods, on which the majority of the safety investigations are based, cannot be used to determine a leakage current threshold. The confidence rating procedure of the modem signal detection theory yields a value of 179.5 μA (rms) at 50 Hz power supply net frequency as the lower end of the 95% confidence range considering the variance in the investigated group. This value is expected to be free of adaptation influences, and is distinctly lower than the European limits and supports the stricter regulations of Canada and USA.展开更多
It has been reported that the serum level of vitamin D3(Vit D3) could affect the natural course of chronic hepatitis C(CH-C) and the response to treatment with pegylated interferon(Peg-IFN) and ribavirin. Although sev...It has been reported that the serum level of vitamin D3(Vit D3) could affect the natural course of chronic hepatitis C(CH-C) and the response to treatment with pegylated interferon(Peg-IFN) and ribavirin. Although several mechanisms for the favorable effects of Vit D3 supplementation were reported, the total effect of Vit D3 supplementation remains unclear. Previously, we reported that supplementation with 1(OH)Vit D3 could enhance the Th1 response inducing not only a favorable immune response for viral eradication but also HCC control. Recently, the main treatment of CH-C should be direct acting antivirals(DAAs) without PegIFN. Peg-IFN is a strong immune-modulator. Therefore, an immunological analysis should be carried out to understand the effect of Vit D3 after treatment of DAAs without Peg-IFN. The induction of a favorable immune response by adding Vit D3 might be able to suppress the hepatocarcinogenesis after achieving SVR, especially in children and elderly patients with severe fibrosis lacking sufficient amounts of VitD 3.展开更多
文摘Leakage currents, tiny currents flowing from an everyday-life appliance through the body to the ground, can cause a non-adequate perception (called electrocutaneous sensation, ECS) or even pain and should be avoided. Safety standards for low-frequency range are based on experimental results of current thresholds of electrocutaneous sensations, which however show a wide range between about 50 pA (rms) and 1000 μA (rms). In order to be able to explain these differences, the perception threshold was measured repeatedly in experiments with test persons under identical experimental setup, but by means of different methods (measuring strategies), namely: direct adjustment, classical threshold as amperage of 50% perception probability, and confidence rating procedure of signal detection theory. The current is injected using a I cm2 electrode at the highly touch sensitive part of the index fingertip. These investigations show for the first time that the threshold of electrocutaneous sensations is influenced both by adaptation to the non-adequate stimulus and individual, emotional factors. Theretbre, classical methods, on which the majority of the safety investigations are based, cannot be used to determine a leakage current threshold. The confidence rating procedure of the modem signal detection theory yields a value of 179.5 μA (rms) at 50 Hz power supply net frequency as the lower end of the 95% confidence range considering the variance in the investigated group. This value is expected to be free of adaptation influences, and is distinctly lower than the European limits and supports the stricter regulations of Canada and USA.
文摘It has been reported that the serum level of vitamin D3(Vit D3) could affect the natural course of chronic hepatitis C(CH-C) and the response to treatment with pegylated interferon(Peg-IFN) and ribavirin. Although several mechanisms for the favorable effects of Vit D3 supplementation were reported, the total effect of Vit D3 supplementation remains unclear. Previously, we reported that supplementation with 1(OH)Vit D3 could enhance the Th1 response inducing not only a favorable immune response for viral eradication but also HCC control. Recently, the main treatment of CH-C should be direct acting antivirals(DAAs) without PegIFN. Peg-IFN is a strong immune-modulator. Therefore, an immunological analysis should be carried out to understand the effect of Vit D3 after treatment of DAAs without Peg-IFN. The induction of a favorable immune response by adding Vit D3 might be able to suppress the hepatocarcinogenesis after achieving SVR, especially in children and elderly patients with severe fibrosis lacking sufficient amounts of VitD 3.