用“有机硅凝胶”灌注高电位变压器
1
作者 卞世超 《火控雷达技术》 1992年第2期34-35,18,共3页
有机硅凝胶具有优良的电气性能,能够在-60~+180℃的温度范围内长期工作。将该材料用于高压电子变压器,能有效地克服注油式和灌注环氧树脂结构存在的缺点,并在减小产品体积和降低重量方面有显著的效果。
关键词 有机硅凝胶 绝缘 灌注 电位变压器
下载PDF
The Influence of Surge Arrester Location on Over-Voltages Caused by Direct Lightning Strikes to MV Lines
2
作者 Alexandre Piantini Thais O. de Carvalho +3 位作者 Paulo F. Obase Jorge M. Janiszewski Gilnei J. G. Santos Donorvan R. Fagundes 《Journal of Energy and Power Engineering》 2014年第3期508-514,共7页
In the period 2003-2011, lightning over-voltages accounted for about 47% of the total number of distribution transformer failures observed in the service area ofAES Sul, a power company that operates in the state of R... In the period 2003-2011, lightning over-voltages accounted for about 47% of the total number of distribution transformer failures observed in the service area ofAES Sul, a power company that operates in the state of Rio Grande doSul, in South Brazil. This paper presents the results of an investigation on the influence of the distance between transformer and MV arresters on the surges at the transformer windings caused by direct strikes to the MV network. The analysis, performed through simulations using the Alternative Transients Program, shows that in general higher voltages are produced by subsequent strokes. Although in relation to the primary side the surges transferred to the secondary are much less affected by the distance between transformers and primary arresters, such distance should always be kept as short as possible in order to reduce the probability of occurrence of transformer failures due to over-voltages at the MV bushings. 展开更多
关键词 Distribution transformer lightning surges overvoltages.
下载PDF
Fiber Laser Sensor Based on a Phase-Shifted Chirped Grating for Acoustic Sensing of Partial Discharges 被引量:5
3
作者 Sanderson E. U. LIMA Rubem G FARIAS +4 位作者 Francisco M. ARAUJO Luis A. FERREIRA José L. SANTOS Vladimiro MIRANDA1 Orlando FRAZAO 《Photonic Sensors》 SCIE EI CAS 2013年第1期44-51,共8页
Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power tr... Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power transformers, and the differentiation from other sources of acoustic emission is of the utmost importance. This paper reports the development of a new sensor concept - a fiber laser sensor based on a phase-shifted chirped fiber grating - for the acoustic emission detection of incipient faults in oil-filled power transformers. These sensors can be placed in the inner surface of the transformer tank wall, not affecting the insulation integrity of the structure and improving fault detection and location. The performance of the sensing head is characterized and compared for different surrounding media: air, water, and oil. The results obtained indicate the feasibility of this sensing approach for the industrial development of practical solutions. 展开更多
关键词 Transformer insulation partial discharges acoustic detection fiber laser sensors
原文传递
Temperature and Concentration Fields in a Generator Integrated to Single Stage Heat Transformer Using Water/Carrol Mixture
4
作者 E.Gómez-Arias J.Ibarra-Bahena +3 位作者 L.Velazquez-Avelar R.J.Romero A.Rodriguez-Martinez M.Montiel-González 《Journal of Thermal Science》 SCIE EI CAS CSCD 2014年第6期564-571,共8页
The generator is the starter device of single stage heat transformer(SSHT) and its characteristics have main effects on the overall efficiency of this kind of absorption machines.This article reports a study of the ge... The generator is the starter device of single stage heat transformer(SSHT) and its characteristics have main effects on the overall efficiency of this kind of absorption machines.This article reports a study of the generation of steam and changes in the concentration of the working solution(Water/Carrol mixture) into a plate heat exchanger as a function of its horizontal and vertical position by gravity effect.It is considered the analysis of six experimental tests;two were evaluated in a plate heat exchanger in a horizontal position and four in a vertical position(90 degree inclination).The generation of steam and increased concentration of the working solution are more sensitive to the vertical position of exchanger than in horizontal position.The results of numerical-experimental analysis indicates that a heat exchanger in horizontal position,the steam generation and the change in the concentration of the working solution occurring in the middle of the plate(or at greater distance depending to the thermodynamic conditions) and instantly in vertical position(at the input of the plate). 展开更多
关键词 Single stage heat transformer Plate heat exchanger Numerical modeling Temperature and concentration field Water/Carrol mixture