A television based multistatic radar system is described. The commercial television transmitter is used as the illuminator in the multistatic radar system. The reflected commercial television signals are measured by ...A television based multistatic radar system is described. The commercial television transmitter is used as the illuminator in the multistatic radar system. The reflected commercial television signals are measured by an array of sensors. A data processing scheme is developed that adapts to the poor signal processing ability. The innovation is focused on the construction of the observation space, which could reduce the non linearity error. The new method leads to better system stability than the traditional one. Monte Carlo simulation is utilized and compared with the traditional method.展开更多
A surface electromyography(sEMG)signal acquisition circuit based on high-order filtering is designed.We use a two-stage adjustable amplifier and a high-order Sallen-Key bandpass filter to solve the problems of non-adj...A surface electromyography(sEMG)signal acquisition circuit based on high-order filtering is designed.We use a two-stage adjustable amplifier and a high-order Sallen-Key bandpass filter to solve the problems of non-adjustable amplification gain and low filtering order in traditional acquisition circuits.The experimental results show that the designed sEMG signal acquisition device can eliminate power frequency interference effectively,the stopband drop of the filtering part reaches approximately-100 dB/dec,which can effectively extract useful signals between 20-500 Hz,and the amplification gain reaches 60 dB.展开更多
Since the gas infrared absorption spectrum source intensity of several in a thousand, it is even less linewidth is only several nanometers occupying the than the noise of light source. The signal of gas absorption is ...Since the gas infrared absorption spectrum source intensity of several in a thousand, it is even less linewidth is only several nanometers occupying the than the noise of light source. The signal of gas absorption is submerged in the noise, so it is impossible to measure the concentration of gas with spectrum absorption directly. According to the principle and parameters of difference absorption system of CH4 gas, a detection circuit consisted of the lock-in amplifier is designed. The experiment results indicated that the detection circuit can satisfy the demand of the whole system, and the limit concentration is 150×10^-6.展开更多
文摘A television based multistatic radar system is described. The commercial television transmitter is used as the illuminator in the multistatic radar system. The reflected commercial television signals are measured by an array of sensors. A data processing scheme is developed that adapts to the poor signal processing ability. The innovation is focused on the construction of the observation space, which could reduce the non linearity error. The new method leads to better system stability than the traditional one. Monte Carlo simulation is utilized and compared with the traditional method.
基金Science and Technology Plan Project of Weinan City(No.2020ZDYF-JCYJ-177)Power Supply Technology Innovation Team of Shaanxi Railway Engineering Vocational and Technical College(No.KJTD201901)Graduate Program Funded Project of Shaanxi Railway Engineering Vocational and Technical College Scientific Research Fund(No.KY2018-77)。
文摘A surface electromyography(sEMG)signal acquisition circuit based on high-order filtering is designed.We use a two-stage adjustable amplifier and a high-order Sallen-Key bandpass filter to solve the problems of non-adjustable amplification gain and low filtering order in traditional acquisition circuits.The experimental results show that the designed sEMG signal acquisition device can eliminate power frequency interference effectively,the stopband drop of the filtering part reaches approximately-100 dB/dec,which can effectively extract useful signals between 20-500 Hz,and the amplification gain reaches 60 dB.
基金Doctorate Foundation of Hebei Province(03547020D) Natural Science Foundation of Heilongjiang Province(F0312)
文摘Since the gas infrared absorption spectrum source intensity of several in a thousand, it is even less linewidth is only several nanometers occupying the than the noise of light source. The signal of gas absorption is submerged in the noise, so it is impossible to measure the concentration of gas with spectrum absorption directly. According to the principle and parameters of difference absorption system of CH4 gas, a detection circuit consisted of the lock-in amplifier is designed. The experiment results indicated that the detection circuit can satisfy the demand of the whole system, and the limit concentration is 150×10^-6.