期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
基于碳纳米管和离子液体复合物修饰玻碳电极电催化测定己烯雌酚
1
作者 陶菡 张义明 张学俊 《理化检验(化学分册)》 CAS CSCD 北大核心 2009年第9期1111-1113,1119,共4页
提出了碳纳米管和离子液体复合物修饰电极测定己烯雌酚(DES)的方法,考察了试验参数对测定的影响。在优化条件下,峰电流与己烯雌酚浓度在两个区间,即从5.0×10^(-8)至1.0×10^(-6)mol·L^(-1)和从1.0×10^(-6)至7.5×... 提出了碳纳米管和离子液体复合物修饰电极测定己烯雌酚(DES)的方法,考察了试验参数对测定的影响。在优化条件下,峰电流与己烯雌酚浓度在两个区间,即从5.0×10^(-8)至1.0×10^(-6)mol·L^(-1)和从1.0×10^(-6)至7.5×10^(-6)mol·L^(-1)范围内呈线性关系,检出限(3S/N)为2.0×10^(-8)mol·L^(-1)。测定了注射液和环境水样中己烯雌酚含量,注射液中己烯雌酚的测定结果与标示量相符,在环境水样中加入3种不同浓度的已烯雌酚进行回收试验,回收率在96.8%~103.0%之间。 展开更多
关键词 电催化-伏安法 碳纳米管 离子液体 己烯雌酚
下载PDF
Electrocatalytic behaviour of Ni and NiCu alloy modified glassy carbon electrode in electro-oxidation of contraflam 被引量:1
2
作者 Naeemy Ali Mohammadi Ali +1 位作者 Ehsani Ali Aghassi Ali 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第8期1703-1712,共10页
The electrocatalytic oxidation of contraflam was investigated in alkaline solution on nickel and nickel–copper alloy modified glassy carbon electrodes(GC/Ni and GC/NiCu). We prepared these electrodes by galvanostatic... The electrocatalytic oxidation of contraflam was investigated in alkaline solution on nickel and nickel–copper alloy modified glassy carbon electrodes(GC/Ni and GC/NiCu). We prepared these electrodes by galvanostatic deposition and the surface morphologies and compositions of electrodes were determined by energy-dispersive X-ray(EDX) and scanning electron microscopy(SEM). Cyclic voltammetry and chronoamperometric methods were employed to characterize the oxidation process and its kinetics. Voltammetric studies exhibit one pair of well-defined redox peaks, which is ascribed to the redox process of the nickel and followed by the greatly enhanced current response of the anodic peak in the presence of contraflam and a decrease in the corresponding cathodic current peak. This indicates that the immobilized redox mediator on the electrode surface was oxidized contraflam via an electrocatalytic mechanism. The catalytic currents increased linearly with the concentration of contraflam in the range of 0.25– 1.5 mmol/L. The anodic peak currents were linearly proportional to the square root of scan rate. This behaviour is the characteristic of a diffusion-controlled process. The determination of contraflam in capsules is applied satisfactorily by modified electrode. 展开更多
关键词 galvanostatic deposition nickel nickel-copper alloy contraflam modified electrodes cyclic voltammetry oxidation
下载PDF
Electrochimical determination of uric acid, xanthine and hypoxanthine by poly(xylitol) modified glassy carbon electrode 被引量:1
3
作者 窦志宇 崔丽莉 何兴权 《Journal of Central South University》 SCIE EI CAS 2014年第3期870-876,共7页
The novel covalently modified glassy carbon electrode with poly(xylitol) was prepared using an electropolymerization technique for the simultaneous determination of uric acid(UA), xanthine(XA) and hypoxanthine(HX). Th... The novel covalently modified glassy carbon electrode with poly(xylitol) was prepared using an electropolymerization technique for the simultaneous determination of uric acid(UA), xanthine(XA) and hypoxanthine(HX). This new electrode presents an excellent electrocatalytic activity towards the oxidation of UA, XA and HX by cyclic voltammetry(CV) method. The oxidation peaks of the three compounds were well defined and had enhanced the peak currents. The separation potentials of the oxidation peak potentials for UA-XA and XA-HX were 380 and 370 mV in CV, respectively. Using differential pulse voltammetry(DPV) method, the calibration curves in the ranges of 5-55, 1.3-75.3 and 4-59 μmol/L were obtained for HX, XA and UA, respectively. The lowest detection limits(S/N=3) were 4.5, 0.75 and 3.75 μmol/L for HX, XA and UA, respectively. The practical application of the modified electrode was demonstrated by the determination of UA, XA, HX in human urine samples. 展开更多
关键词 XYLITOL ELECTROPOLYMERIZATION uric acid XANTHINE HYPOXANTHINE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部