干式变压器发展新动向 被引量:16
1
作者 郭振岩 刘景江 《变压器》 北大核心 2002年第5期6-9,共4页
简要回顾了国内干式变压器技术的现状及存在问题,综述了干式变压器发展的新动向,并对几种H级绝缘敞开通风干式变压器进行了比较。
关键词 干式 H级绝缘 绝缘材料 电力变电压器
下载PDF
Influence analysis of local heat source on internal temperature distribution of power transformer 被引量:2
2
作者 BAO Yanyan FENG Tingna +3 位作者 ZHANG Guangdong LIU Kang MA Jianqiao ZHOU Xiaodong 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2021年第2期218-225,共8页
Oil immersed power transformer is the main electrical equipment in power system.Its operation reliability has an important impact on the safe operation of power system.In the process of production,installation and ope... Oil immersed power transformer is the main electrical equipment in power system.Its operation reliability has an important impact on the safe operation of power system.In the process of production,installation and operation,its insulation structure may be damaged,resulting in partial discharge and even breakdown inside the transformer.In this paper,S9-M-100/10 oil immersed distribution transformer is taken as the research object,and the distribution laws of electromagnetic field and temperature field in transformer under normal operation,inter turn short circuit and inter layer short circuit are simulated and analyzed.The simulation results show that under normal conditions,the temperatures at the oil gap between the transformer core and the high and low voltage windings and the middle position of the high-voltage winding are high.When there are inter turn and inter layer short circuit faults,the electromagnetic loss of the fault part of the transformer increases,and the temperature rises suddenly.The influence of the two faults on the internal temperature field of the transformer is different,and the influence of the inter turn short circuit fault on the temperature nearby is obvious.The analysis results can provide reference for the thermal fault interpretation and fault classification of transformer. 展开更多
关键词 oil immersed power transformer finite element method electromagnetic field short circuit fault temperature field
下载PDF
State of the Art and Future Trends of Unconventional PD-Measurement at Power Transformers 被引量:1
3
作者 Jurgen Fabian Martin Neuwersch +2 位作者 Christof Sumereder Michael Muhr Robert Schwarz 《Journal of Energy and Power Engineering》 2014年第6期1093-1098,共6页
This paper discusses the current state of the art of diagnostics at power transformers. A special focus is set on the UHF-PD-measurement (ultra-high-frequency partial discharge measurement) because at power transfor... This paper discusses the current state of the art of diagnostics at power transformers. A special focus is set on the UHF-PD-measurement (ultra-high-frequency partial discharge measurement) because at power transformers, this diagnostic method has become more important in recent years. The current state, basics and principles of operations, proceedings as well as advantages of PD-measurement methods are covered. Furthermore problems and proposed solutions are discussed. Bushings and tap changers are not discussed in detail. In many cases, one single diagnostic method does not have the ability to sufficiently evaluate a power transformer. Therefore, a variety of diagnostic methods came up over times, which are commonly used by now. To expand the evaluation opportunities of power transformers, science strives to develop new diagnostic methods as well as to improve the existing ones. Furthermore, environmentally friendly and hardly inflammable ester liquids are examined for the use at power transformers and PD-measurement at HVDC (high voltage direct current) converter transformers as well. Potential diagnostic options and respectively current developments and findings in the field of oil-paper-insulation systems are outlined conclusively. 展开更多
关键词 Power transformer unconventional PD-measurement UHF-PD-measurement environmentally friendly alternativeinsulating liquids HVDC converter transformer.
下载PDF
Detection of Partial Discharge in Power Transformers Using Rogowski Coil and Multiresolution Analysis 被引量:1
4
作者 G.F.C. Veloso L.E. Borges da Silva +4 位作者 I. Noronha G. Lambert Torres J. Haddad R.R. Pereira Se UnAhn 《Journal of Energy and Power Engineering》 2010年第2期39-45,共7页
Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and e... Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and empirical mode decomposition. Detecting and analyzing incipient activities of partial discharge can provide useful information to diagnostics and prognostics about transformer insulation. So, partial discharge signals embedded in the electric current at ground conductor are measured using the Rogowski coil. These signals are submitted to noise suppression and the partial discharges waveforms are extracted through different ways: using discrete wavelet transform and using empirical mode decomposition. The comparison of these two methods show that the extraction with discrete wavelet transform results in a faster and simpler algorithm than the empirical mode decomposition. But this one produces more precise waveforms due its adaptive characteristic. 展开更多
关键词 Discrete wavelet transform empirical mode decomposition partial discharge power transformer Rogowski coil.
下载PDF
Insulation System of Power Transformers Behavior Comparison of Mineral Oils and Natural Ester Dielectric Fluids 被引量:6
5
作者 R. Polansky P. Prosr V Mentlik J. Pihera P. Trnka 《Journal of Energy and Power Engineering》 2010年第12期51-56,共6页
Paper deals with a comparison of selected properties of several vegetable oil representatives along their accelerated thermal ageing at the temperature of 90 ℃. These properties are compared to two widely used and co... Paper deals with a comparison of selected properties of several vegetable oil representatives along their accelerated thermal ageing at the temperature of 90 ℃. These properties are compared to two widely used and commercially available mineral transformer oils. A combined insulating system (an oil-paper system) was created with the usage of mentioned oils for measurement purposes. Dissipation factor, capacity and volume resistance are characteristics measured along a thermal ageing of the oil-paper systems. Infrared spectroscopy was used as an additional method. After 1,000 hours of ageing, the dissipation factor of all systems based on vegetable oils did not exceed the value of 0.015. The volume resistance of systems containing mineral oils was approx, twice as high as the volume resistance of those with vegetable oils. The capacity on the other hand was slightly lower in the case of mineral oils application. An experiment also showed that the paper combined with the vegetable oil dries more quickly than in combination with the mineral oil. Infrared spectroscopy has not shown any expressive changes in the chemical structure of aU tested oils yet (up to 1,000 hours of ageing). 展开更多
关键词 Power transformer ECOSYSTEM biodegradable oils electrical properties.
下载PDF
Modelling and Analysis of Distribution Network with HTS Transformer
6
作者 Muhammad Azizi Abdul Rahman Tek-Tjing Lie Krishnamachar Prasad 《Journal of Energy and Power Engineering》 2012年第4期580-590,共11页
Transformers utilizing HTS (high temperature superconductors) are considered as a timely invention. The number of power transformers age more than 30 years old and nearing retirement is increasing. If this window of... Transformers utilizing HTS (high temperature superconductors) are considered as a timely invention. The number of power transformers age more than 30 years old and nearing retirement is increasing. If this window of opportunity is not grabbed, there would be great reluctance to replace recently installed highly priced capital asset. Major projects of developing HTS transformers are well making progress in the United States, Europe, Japan, Korea and China which indicate the interest. The efforts must have been appropriately verified through the economic interest of the discounted losses. Consequently, it is very important to develop an understanding of the fundamental HTS transformer design issues that can provide guidance for developing practical devices of interest to the electric utility industry. The parameters of HTS transformer need to be validated before any effort is to carry out to model the behaviour of a distribution network under a range of conditions. The predicted performance and reliability of HTS transformers can then be verified through the network modelling and analysis calculation. The ultimate purpose is to furnish electric utilities precise information as to which HTS transformers work under various applications with greater technical efficiency and proven reliability. 展开更多
关键词 High temperature superconductor TRANSFORMER distribution system network modelling.
下载PDF
Ferroresonance at Open Phase Operating Conditions of Power Transformers
7
作者 Hani Obeid 《Journal of Energy and Power Engineering》 2012年第10期1714-1717,共4页
The reliability of electric supply to consumers is one of the most important factors that determine the requirements imposed on modem utility companies. This paper presents the results of investigation by computer sof... The reliability of electric supply to consumers is one of the most important factors that determine the requirements imposed on modem utility companies. This paper presents the results of investigation by computer software of the overvoltages resulting from a ferroresonance conditions in MV networks at open phase operating condition with and without connection to earth on source and load sides of distribution transformer. This overvoltage may reach 4.2 pu on one of the HV side of transformer unswitched phases. The results of the study show that ferroresonance overvoltage may be controlled by replacing fuses with circuit breakers on HV side to ensure switching-off all phases. Insertion of resistor or reactor in the neutral of source and loadsides of the transformer with 5% active load will help in suppressing overvoltages. 展开更多
关键词 FERRORESONANCE OVERVOLTAGE open phase operating condition non-linear inductance.
下载PDF
A Tool for the Assessment of the Electromagnetic Forces in Power Distribution Transformers
8
作者 A. da Costa Lopes M.A. Sanz-Bobi +3 位作者 L. Rouco R. Palacios L. Flores P. Cirujano 《Journal of Energy and Power Engineering》 2011年第10期972-977,共6页
This paper compares the estimated electromagnetic forces due to short circuits in power transformers using two computational models. The first model is based on approximate analytical expressions of the electromagneti... This paper compares the estimated electromagnetic forces due to short circuits in power transformers using two computational models. The first model is based on approximate analytical expressions of the electromagnetic lbrces as they have been compiled in earlier versions of the IEC standard 60076-5. The second model is based on a finite element model of the transformer using the software FEMM (Finite Element Method Magnetics). The paper shows how valid the analytical model is for design purposes. Results have been obtained and compared from both models in a number of actual power distribution transformers. It is possible to conclude that the analytical formulation provides satisfactory results for the design of power transformers compared to detailed finite element models. A tool has been designed for this purpose and the main features of it will be described in the paper. 展开更多
关键词 Electromagnetic forces power transformer SHORT-CIRCUIT IEC 60076-5.
下载PDF
Study on Over-Voltage of 220 kV Transformer's Neutrals and Protection Strategy
9
作者 H.P. Yu S.M. Chen +2 位作者 P.C. Yang H. Yin G.L. Wu 《Journal of Energy and Power Engineering》 2011年第11期1102-1108,共7页
In order to limit short-circuit current and satisfy the need of relay setting, only part of the 220 kV power transformer is grounded, so on the neutrals of ungrounded transformers will appear the over-voltage. Current... In order to limit short-circuit current and satisfy the need of relay setting, only part of the 220 kV power transformer is grounded, so on the neutrals of ungrounded transformers will appear the over-voltage. Currently the value of over-voltage on transformer neutral point and the corresponding protection strategy is based on theoretical formula. This article uses the PSCAD/EMTDC software to calculate the over-voltage on the neutral point of 4 ungrounded power transformers in Chongqing 220 kV power grid. The result shows that the power frequency transient over-voltage on the neutrals may reach 178 kV. If the single-phase grounding fault occurs in ungrounded power system, the power frequency over-voltage on the neutrals will be more serious and rise to 138.6 kV. Non-full phase operation may cause serious ferro-resonance over-voltage on the neutrals of no-load transformer, which may last for seconds and may rise to 723.7 kV, causing serious threat to the transformer neutrals and line-side equipment. The article also studies the gap parameter which should be taken on the neutrals of 220 kV transformers at the end. 展开更多
关键词 Neutral point power transformer ARRESTER GAP power frequency over-voltage lightning over-voltage.
下载PDF
Considerations of Electricity Supply Quality in Spain
10
作者 Rafael Munoz SergioValero +1 位作者 Demetrio Lopez Carolina Senabre 《Journal of Energy and Power Engineering》 2012年第12期1976-1983,共8页
The quality of supply in Spain is regulated by Act 54/1997 as the basic standard and further developed by Royal Decree 1955/2000, among others. Also this law (1997) introduces the division between generators, distri... The quality of supply in Spain is regulated by Act 54/1997 as the basic standard and further developed by Royal Decree 1955/2000, among others. Also this law (1997) introduces the division between generators, distribution companies and retailers. The aim of this paper is to provide an overview of the fundamental parameters to be taken into account when examining the status of national regulations in Spain on the quality of electricity supply, in addition to describing the various agents intervening in these. There are two more aspects to consider: the guarantee of supply and energy is provided at the lowest cost to consumers. The authors propose to include phase-shifting transformers at specific strategic points, in accordance with power flow control principles in parallel circuits. Finally, it can be concluded that Royal Decree 222/2008 needs reviewing and applying effectively, as do modifications to Royal Decree 1995/2000 providing remuneration that effectively induces electricity companies to invest in their networks, and ends with "a well-paid electricity company is obliged to invest in network improvements". 展开更多
关键词 Power distribution power quality quality of supply.
下载PDF
Fiber Laser Sensor Based on a Phase-Shifted Chirped Grating for Acoustic Sensing of Partial Discharges 被引量:5
11
作者 Sanderson E. U. LIMA Rubem G FARIAS +4 位作者 Francisco M. ARAUJO Luis A. FERREIRA José L. SANTOS Vladimiro MIRANDA1 Orlando FRAZAO 《Photonic Sensors》 SCIE EI CAS 2013年第1期44-51,共8页
Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power tr... Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power transformers, and the differentiation from other sources of acoustic emission is of the utmost importance. This paper reports the development of a new sensor concept - a fiber laser sensor based on a phase-shifted chirped fiber grating - for the acoustic emission detection of incipient faults in oil-filled power transformers. These sensors can be placed in the inner surface of the transformer tank wall, not affecting the insulation integrity of the structure and improving fault detection and location. The performance of the sensing head is characterized and compared for different surrounding media: air, water, and oil. The results obtained indicate the feasibility of this sensing approach for the industrial development of practical solutions. 展开更多
关键词 Transformer insulation partial discharges acoustic detection fiber laser sensors
原文传递