Oil immersed power transformer is the main electrical equipment in power system.Its operation reliability has an important impact on the safe operation of power system.In the process of production,installation and ope...Oil immersed power transformer is the main electrical equipment in power system.Its operation reliability has an important impact on the safe operation of power system.In the process of production,installation and operation,its insulation structure may be damaged,resulting in partial discharge and even breakdown inside the transformer.In this paper,S9-M-100/10 oil immersed distribution transformer is taken as the research object,and the distribution laws of electromagnetic field and temperature field in transformer under normal operation,inter turn short circuit and inter layer short circuit are simulated and analyzed.The simulation results show that under normal conditions,the temperatures at the oil gap between the transformer core and the high and low voltage windings and the middle position of the high-voltage winding are high.When there are inter turn and inter layer short circuit faults,the electromagnetic loss of the fault part of the transformer increases,and the temperature rises suddenly.The influence of the two faults on the internal temperature field of the transformer is different,and the influence of the inter turn short circuit fault on the temperature nearby is obvious.The analysis results can provide reference for the thermal fault interpretation and fault classification of transformer.展开更多
This paper discusses the current state of the art of diagnostics at power transformers. A special focus is set on the UHF-PD-measurement (ultra-high-frequency partial discharge measurement) because at power transfor...This paper discusses the current state of the art of diagnostics at power transformers. A special focus is set on the UHF-PD-measurement (ultra-high-frequency partial discharge measurement) because at power transformers, this diagnostic method has become more important in recent years. The current state, basics and principles of operations, proceedings as well as advantages of PD-measurement methods are covered. Furthermore problems and proposed solutions are discussed. Bushings and tap changers are not discussed in detail. In many cases, one single diagnostic method does not have the ability to sufficiently evaluate a power transformer. Therefore, a variety of diagnostic methods came up over times, which are commonly used by now. To expand the evaluation opportunities of power transformers, science strives to develop new diagnostic methods as well as to improve the existing ones. Furthermore, environmentally friendly and hardly inflammable ester liquids are examined for the use at power transformers and PD-measurement at HVDC (high voltage direct current) converter transformers as well. Potential diagnostic options and respectively current developments and findings in the field of oil-paper-insulation systems are outlined conclusively.展开更多
Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and e...Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and empirical mode decomposition. Detecting and analyzing incipient activities of partial discharge can provide useful information to diagnostics and prognostics about transformer insulation. So, partial discharge signals embedded in the electric current at ground conductor are measured using the Rogowski coil. These signals are submitted to noise suppression and the partial discharges waveforms are extracted through different ways: using discrete wavelet transform and using empirical mode decomposition. The comparison of these two methods show that the extraction with discrete wavelet transform results in a faster and simpler algorithm than the empirical mode decomposition. But this one produces more precise waveforms due its adaptive characteristic.展开更多
Paper deals with a comparison of selected properties of several vegetable oil representatives along their accelerated thermal ageing at the temperature of 90 ℃. These properties are compared to two widely used and co...Paper deals with a comparison of selected properties of several vegetable oil representatives along their accelerated thermal ageing at the temperature of 90 ℃. These properties are compared to two widely used and commercially available mineral transformer oils. A combined insulating system (an oil-paper system) was created with the usage of mentioned oils for measurement purposes. Dissipation factor, capacity and volume resistance are characteristics measured along a thermal ageing of the oil-paper systems. Infrared spectroscopy was used as an additional method. After 1,000 hours of ageing, the dissipation factor of all systems based on vegetable oils did not exceed the value of 0.015. The volume resistance of systems containing mineral oils was approx, twice as high as the volume resistance of those with vegetable oils. The capacity on the other hand was slightly lower in the case of mineral oils application. An experiment also showed that the paper combined with the vegetable oil dries more quickly than in combination with the mineral oil. Infrared spectroscopy has not shown any expressive changes in the chemical structure of aU tested oils yet (up to 1,000 hours of ageing).展开更多
Transformers utilizing HTS (high temperature superconductors) are considered as a timely invention. The number of power transformers age more than 30 years old and nearing retirement is increasing. If this window of...Transformers utilizing HTS (high temperature superconductors) are considered as a timely invention. The number of power transformers age more than 30 years old and nearing retirement is increasing. If this window of opportunity is not grabbed, there would be great reluctance to replace recently installed highly priced capital asset. Major projects of developing HTS transformers are well making progress in the United States, Europe, Japan, Korea and China which indicate the interest. The efforts must have been appropriately verified through the economic interest of the discounted losses. Consequently, it is very important to develop an understanding of the fundamental HTS transformer design issues that can provide guidance for developing practical devices of interest to the electric utility industry. The parameters of HTS transformer need to be validated before any effort is to carry out to model the behaviour of a distribution network under a range of conditions. The predicted performance and reliability of HTS transformers can then be verified through the network modelling and analysis calculation. The ultimate purpose is to furnish electric utilities precise information as to which HTS transformers work under various applications with greater technical efficiency and proven reliability.展开更多
The reliability of electric supply to consumers is one of the most important factors that determine the requirements imposed on modem utility companies. This paper presents the results of investigation by computer sof...The reliability of electric supply to consumers is one of the most important factors that determine the requirements imposed on modem utility companies. This paper presents the results of investigation by computer software of the overvoltages resulting from a ferroresonance conditions in MV networks at open phase operating condition with and without connection to earth on source and load sides of distribution transformer. This overvoltage may reach 4.2 pu on one of the HV side of transformer unswitched phases. The results of the study show that ferroresonance overvoltage may be controlled by replacing fuses with circuit breakers on HV side to ensure switching-off all phases. Insertion of resistor or reactor in the neutral of source and loadsides of the transformer with 5% active load will help in suppressing overvoltages.展开更多
This paper compares the estimated electromagnetic forces due to short circuits in power transformers using two computational models. The first model is based on approximate analytical expressions of the electromagneti...This paper compares the estimated electromagnetic forces due to short circuits in power transformers using two computational models. The first model is based on approximate analytical expressions of the electromagnetic lbrces as they have been compiled in earlier versions of the IEC standard 60076-5. The second model is based on a finite element model of the transformer using the software FEMM (Finite Element Method Magnetics). The paper shows how valid the analytical model is for design purposes. Results have been obtained and compared from both models in a number of actual power distribution transformers. It is possible to conclude that the analytical formulation provides satisfactory results for the design of power transformers compared to detailed finite element models. A tool has been designed for this purpose and the main features of it will be described in the paper.展开更多
In order to limit short-circuit current and satisfy the need of relay setting, only part of the 220 kV power transformer is grounded, so on the neutrals of ungrounded transformers will appear the over-voltage. Current...In order to limit short-circuit current and satisfy the need of relay setting, only part of the 220 kV power transformer is grounded, so on the neutrals of ungrounded transformers will appear the over-voltage. Currently the value of over-voltage on transformer neutral point and the corresponding protection strategy is based on theoretical formula. This article uses the PSCAD/EMTDC software to calculate the over-voltage on the neutral point of 4 ungrounded power transformers in Chongqing 220 kV power grid. The result shows that the power frequency transient over-voltage on the neutrals may reach 178 kV. If the single-phase grounding fault occurs in ungrounded power system, the power frequency over-voltage on the neutrals will be more serious and rise to 138.6 kV. Non-full phase operation may cause serious ferro-resonance over-voltage on the neutrals of no-load transformer, which may last for seconds and may rise to 723.7 kV, causing serious threat to the transformer neutrals and line-side equipment. The article also studies the gap parameter which should be taken on the neutrals of 220 kV transformers at the end.展开更多
The quality of supply in Spain is regulated by Act 54/1997 as the basic standard and further developed by Royal Decree 1955/2000, among others. Also this law (1997) introduces the division between generators, distri...The quality of supply in Spain is regulated by Act 54/1997 as the basic standard and further developed by Royal Decree 1955/2000, among others. Also this law (1997) introduces the division between generators, distribution companies and retailers. The aim of this paper is to provide an overview of the fundamental parameters to be taken into account when examining the status of national regulations in Spain on the quality of electricity supply, in addition to describing the various agents intervening in these. There are two more aspects to consider: the guarantee of supply and energy is provided at the lowest cost to consumers. The authors propose to include phase-shifting transformers at specific strategic points, in accordance with power flow control principles in parallel circuits. Finally, it can be concluded that Royal Decree 222/2008 needs reviewing and applying effectively, as do modifications to Royal Decree 1995/2000 providing remuneration that effectively induces electricity companies to invest in their networks, and ends with "a well-paid electricity company is obliged to invest in network improvements".展开更多
Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power tr...Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power transformers, and the differentiation from other sources of acoustic emission is of the utmost importance. This paper reports the development of a new sensor concept - a fiber laser sensor based on a phase-shifted chirped fiber grating - for the acoustic emission detection of incipient faults in oil-filled power transformers. These sensors can be placed in the inner surface of the transformer tank wall, not affecting the insulation integrity of the structure and improving fault detection and location. The performance of the sensing head is characterized and compared for different surrounding media: air, water, and oil. The results obtained indicate the feasibility of this sensing approach for the industrial development of practical solutions.展开更多
基金Science and Technology Project of State Grid Gansu Electric Power Company(No.52272219000Q)。
文摘Oil immersed power transformer is the main electrical equipment in power system.Its operation reliability has an important impact on the safe operation of power system.In the process of production,installation and operation,its insulation structure may be damaged,resulting in partial discharge and even breakdown inside the transformer.In this paper,S9-M-100/10 oil immersed distribution transformer is taken as the research object,and the distribution laws of electromagnetic field and temperature field in transformer under normal operation,inter turn short circuit and inter layer short circuit are simulated and analyzed.The simulation results show that under normal conditions,the temperatures at the oil gap between the transformer core and the high and low voltage windings and the middle position of the high-voltage winding are high.When there are inter turn and inter layer short circuit faults,the electromagnetic loss of the fault part of the transformer increases,and the temperature rises suddenly.The influence of the two faults on the internal temperature field of the transformer is different,and the influence of the inter turn short circuit fault on the temperature nearby is obvious.The analysis results can provide reference for the thermal fault interpretation and fault classification of transformer.
文摘This paper discusses the current state of the art of diagnostics at power transformers. A special focus is set on the UHF-PD-measurement (ultra-high-frequency partial discharge measurement) because at power transformers, this diagnostic method has become more important in recent years. The current state, basics and principles of operations, proceedings as well as advantages of PD-measurement methods are covered. Furthermore problems and proposed solutions are discussed. Bushings and tap changers are not discussed in detail. In many cases, one single diagnostic method does not have the ability to sufficiently evaluate a power transformer. Therefore, a variety of diagnostic methods came up over times, which are commonly used by now. To expand the evaluation opportunities of power transformers, science strives to develop new diagnostic methods as well as to improve the existing ones. Furthermore, environmentally friendly and hardly inflammable ester liquids are examined for the use at power transformers and PD-measurement at HVDC (high voltage direct current) converter transformers as well. Potential diagnostic options and respectively current developments and findings in the field of oil-paper-insulation systems are outlined conclusively.
文摘Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and empirical mode decomposition. Detecting and analyzing incipient activities of partial discharge can provide useful information to diagnostics and prognostics about transformer insulation. So, partial discharge signals embedded in the electric current at ground conductor are measured using the Rogowski coil. These signals are submitted to noise suppression and the partial discharges waveforms are extracted through different ways: using discrete wavelet transform and using empirical mode decomposition. The comparison of these two methods show that the extraction with discrete wavelet transform results in a faster and simpler algorithm than the empirical mode decomposition. But this one produces more precise waveforms due its adaptive characteristic.
文摘Paper deals with a comparison of selected properties of several vegetable oil representatives along their accelerated thermal ageing at the temperature of 90 ℃. These properties are compared to two widely used and commercially available mineral transformer oils. A combined insulating system (an oil-paper system) was created with the usage of mentioned oils for measurement purposes. Dissipation factor, capacity and volume resistance are characteristics measured along a thermal ageing of the oil-paper systems. Infrared spectroscopy was used as an additional method. After 1,000 hours of ageing, the dissipation factor of all systems based on vegetable oils did not exceed the value of 0.015. The volume resistance of systems containing mineral oils was approx, twice as high as the volume resistance of those with vegetable oils. The capacity on the other hand was slightly lower in the case of mineral oils application. An experiment also showed that the paper combined with the vegetable oil dries more quickly than in combination with the mineral oil. Infrared spectroscopy has not shown any expressive changes in the chemical structure of aU tested oils yet (up to 1,000 hours of ageing).
文摘Transformers utilizing HTS (high temperature superconductors) are considered as a timely invention. The number of power transformers age more than 30 years old and nearing retirement is increasing. If this window of opportunity is not grabbed, there would be great reluctance to replace recently installed highly priced capital asset. Major projects of developing HTS transformers are well making progress in the United States, Europe, Japan, Korea and China which indicate the interest. The efforts must have been appropriately verified through the economic interest of the discounted losses. Consequently, it is very important to develop an understanding of the fundamental HTS transformer design issues that can provide guidance for developing practical devices of interest to the electric utility industry. The parameters of HTS transformer need to be validated before any effort is to carry out to model the behaviour of a distribution network under a range of conditions. The predicted performance and reliability of HTS transformers can then be verified through the network modelling and analysis calculation. The ultimate purpose is to furnish electric utilities precise information as to which HTS transformers work under various applications with greater technical efficiency and proven reliability.
文摘The reliability of electric supply to consumers is one of the most important factors that determine the requirements imposed on modem utility companies. This paper presents the results of investigation by computer software of the overvoltages resulting from a ferroresonance conditions in MV networks at open phase operating condition with and without connection to earth on source and load sides of distribution transformer. This overvoltage may reach 4.2 pu on one of the HV side of transformer unswitched phases. The results of the study show that ferroresonance overvoltage may be controlled by replacing fuses with circuit breakers on HV side to ensure switching-off all phases. Insertion of resistor or reactor in the neutral of source and loadsides of the transformer with 5% active load will help in suppressing overvoltages.
文摘This paper compares the estimated electromagnetic forces due to short circuits in power transformers using two computational models. The first model is based on approximate analytical expressions of the electromagnetic lbrces as they have been compiled in earlier versions of the IEC standard 60076-5. The second model is based on a finite element model of the transformer using the software FEMM (Finite Element Method Magnetics). The paper shows how valid the analytical model is for design purposes. Results have been obtained and compared from both models in a number of actual power distribution transformers. It is possible to conclude that the analytical formulation provides satisfactory results for the design of power transformers compared to detailed finite element models. A tool has been designed for this purpose and the main features of it will be described in the paper.
文摘In order to limit short-circuit current and satisfy the need of relay setting, only part of the 220 kV power transformer is grounded, so on the neutrals of ungrounded transformers will appear the over-voltage. Currently the value of over-voltage on transformer neutral point and the corresponding protection strategy is based on theoretical formula. This article uses the PSCAD/EMTDC software to calculate the over-voltage on the neutral point of 4 ungrounded power transformers in Chongqing 220 kV power grid. The result shows that the power frequency transient over-voltage on the neutrals may reach 178 kV. If the single-phase grounding fault occurs in ungrounded power system, the power frequency over-voltage on the neutrals will be more serious and rise to 138.6 kV. Non-full phase operation may cause serious ferro-resonance over-voltage on the neutrals of no-load transformer, which may last for seconds and may rise to 723.7 kV, causing serious threat to the transformer neutrals and line-side equipment. The article also studies the gap parameter which should be taken on the neutrals of 220 kV transformers at the end.
文摘The quality of supply in Spain is regulated by Act 54/1997 as the basic standard and further developed by Royal Decree 1955/2000, among others. Also this law (1997) introduces the division between generators, distribution companies and retailers. The aim of this paper is to provide an overview of the fundamental parameters to be taken into account when examining the status of national regulations in Spain on the quality of electricity supply, in addition to describing the various agents intervening in these. There are two more aspects to consider: the guarantee of supply and energy is provided at the lowest cost to consumers. The authors propose to include phase-shifting transformers at specific strategic points, in accordance with power flow control principles in parallel circuits. Finally, it can be concluded that Royal Decree 222/2008 needs reviewing and applying effectively, as do modifications to Royal Decree 1995/2000 providing remuneration that effectively induces electricity companies to invest in their networks, and ends with "a well-paid electricity company is obliged to invest in network improvements".
文摘Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power transformers, and the differentiation from other sources of acoustic emission is of the utmost importance. This paper reports the development of a new sensor concept - a fiber laser sensor based on a phase-shifted chirped fiber grating - for the acoustic emission detection of incipient faults in oil-filled power transformers. These sensors can be placed in the inner surface of the transformer tank wall, not affecting the insulation integrity of the structure and improving fault detection and location. The performance of the sensing head is characterized and compared for different surrounding media: air, water, and oil. The results obtained indicate the feasibility of this sensing approach for the industrial development of practical solutions.