In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. ...In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. Through the simulation analysis, we have obtained some conclusions in terms of the impact of high-penetration PV on the stability. However, for more accurate assessment of the transient stability, it is necessary to analyze various simulation models considering many other power system conditions. This paper presents the results of the analysis for the transient stability simulation performed for IEEE 9-bus system model, in which the effects of various conditions, such as variety of power sources (inverter or rotational machine), load characteristics, existence of LVRT (low-voltage ride-through) capability and fault locations, on the transient stability are investigated.展开更多
An analytical approach for probabilistic evaluation of transient stability of a power system incorporating a wind farm is presented in this study. Based on the fact that the boundary of practical dynamic security regi...An analytical approach for probabilistic evaluation of transient stability of a power system incorporating a wind farm is presented in this study. Based on the fact that the boundary of practical dynamic security region(PDSR) of a power system with double fed induction generators(DFIG) can be approximated by one or few hyper-planes in nodal power injection space, transient stability criterion for given configurations of pre-fault, fault-on and post-fault of a power system is to be expressed by certain expressions of linear combination of nodal injection vector and the transient stability probability(TSP) is further obtained with a much more simplified expression than the complex integral. Furthermore, considering uncertainties of nodal injection power including wind power and load, TSP is calculated analytically by Cornish-Fisher expansion, which can provide reliable evaluation results with high accuracy and much less computing time compared with Monte Carlo simulation. TSP and its visualization can further help operators and planners be aware of the degree of stability or instability and find critical components to monitor and reinforce. Test results on the New England 10-generators and 39-buses power system show the method's effectiveness and significance for probabilistic security assessment.展开更多
文摘In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. Through the simulation analysis, we have obtained some conclusions in terms of the impact of high-penetration PV on the stability. However, for more accurate assessment of the transient stability, it is necessary to analyze various simulation models considering many other power system conditions. This paper presents the results of the analysis for the transient stability simulation performed for IEEE 9-bus system model, in which the effects of various conditions, such as variety of power sources (inverter or rotational machine), load characteristics, existence of LVRT (low-voltage ride-through) capability and fault locations, on the transient stability are investigated.
基金supported by the National Basic Research Program of China("973"Project)(Grant No.2013CB228204)the National Natural Science Foundation of China(Grant No.51407126)Tianjin Natural Science Foundation(Grant No.15JCQNJC07000)
文摘An analytical approach for probabilistic evaluation of transient stability of a power system incorporating a wind farm is presented in this study. Based on the fact that the boundary of practical dynamic security region(PDSR) of a power system with double fed induction generators(DFIG) can be approximated by one or few hyper-planes in nodal power injection space, transient stability criterion for given configurations of pre-fault, fault-on and post-fault of a power system is to be expressed by certain expressions of linear combination of nodal injection vector and the transient stability probability(TSP) is further obtained with a much more simplified expression than the complex integral. Furthermore, considering uncertainties of nodal injection power including wind power and load, TSP is calculated analytically by Cornish-Fisher expansion, which can provide reliable evaluation results with high accuracy and much less computing time compared with Monte Carlo simulation. TSP and its visualization can further help operators and planners be aware of the degree of stability or instability and find critical components to monitor and reinforce. Test results on the New England 10-generators and 39-buses power system show the method's effectiveness and significance for probabilistic security assessment.