基于导波的电厂热管管外自动检测机器人
1
作者 公鑫 《电子世界》 2014年第14期468-469,共2页
在热电厂中,热管(heat pipe)用于实现热量的转移与传导,即作为高效散热元件。然而,由于特殊的热电厂工作环境,热管较易被腐蚀。热管损坏后,热力系统不能很好的传导热量,影响热电厂正常运作,严重时可能导致供电异常。而目前用于热管检漏... 在热电厂中,热管(heat pipe)用于实现热量的转移与传导,即作为高效散热元件。然而,由于特殊的热电厂工作环境,热管较易被腐蚀。热管损坏后,热力系统不能很好的传导热量,影响热电厂正常运作,严重时可能导致供电异常。而目前用于热管检漏的设备比较落后,适应性和自动化程度低,具有很大的局限性。基于以上原因我设计了该款基于导波的热管管外自动检测机器人。能够自动行走检测热管是否有缺陷,并发出警报,能够精确的实现复杂管道环境下转弯、爬升、翻越凸台等运动过程是本设计的创新及特色。 展开更多
关键词 导波 电厂热管 自动检测 管外机器人
下载PDF
Experimental Study of Condensation Heat Transfer on Tube Bundles in Large Power Plant Condensers 被引量:1
2
作者 Koichi Inoue Issaku Fujita +2 位作者 Kotaro Machii Satoshi Hiraoka Manabu Ishihara 《Journal of Energy and Power Engineering》 2014年第5期920-928,共9页
In order to clarify the effect of condensate inundation on steam condensation in a large tube bundle, condensation heat transfer and the condensate flow pattern in the tube bundle have been experimentally investigated... In order to clarify the effect of condensate inundation on steam condensation in a large tube bundle, condensation heat transfer and the condensate flow pattern in the tube bundle have been experimentally investigated. Test tube bundle consists of 36 cooling tubes, 12 condensate supply tubes and 24 un-cooled dummy tubes. Cooling test tubes are made of copper and have an outer diameter of 19.1 mm and condensing length of 150 mm, Steam flows horizontally through the test tube bundle at gap velocities 15-27 m/s at pressures of 8.8 kPa. In this study, experimental data about condensate flow pattern and condensation heat transfer in a tube bundle were collected for the optimization of tube arrangement in large power plant condensers. 展开更多
关键词 CONDENSATION INUNDATION CONDENSER tube bundle tube arrangement power station.
下载PDF
Ammonia corrosion analysis of copper tubes and experimental research on non-copper improvement for heat exchanger in power plant
3
作者 ZENG Zhou-hua LONG Xin-feng LIANG Ping 《Journal of Chemistry and Chemical Engineering》 2009年第12期30-36,共7页
Ammonia corrosion in copper tube will affect the safety of boiler running in power plant. Therefore, no copper in heating system has become a technical orientation in heat exchanger reconstruction, This paper analy... Ammonia corrosion in copper tube will affect the safety of boiler running in power plant. Therefore, no copper in heating system has become a technical orientation in heat exchanger reconstruction, This paper analyzes the condition and mechanism of ammonia corrosion occurring in copper tube used in coal-fired power plants. Using a general steam condensation testing equipment only for horizontal single tube, with water vapor and water as working fluid, on two types of steel tube with 2-side enhancement heat transfer, namely, a spirally fluted tube and a ratchet tube with internal spiral groove (RISG tube) which was developed recently, a set of experimental tests are conducted to investigate the characteristics of heat transfer and hydromeehanics. In order to compare easily, both one copper smooth tube and one steel smooth tube are also used in the experiment. The experimental results, which get from single horizontal tube, show that the overall heat transfer coefficient of steel spirally fluted tube are improved by 10%o to 17%, and that of the steel RISG tube(22%-28%) is better than steel spirally fluted tube, its flow resistance coefficient is only increased by 22% to 66% when compared with smooth tube. Based on a lot of experimental data, the steel spirally fluted tube and the steel RISG tube were applied in a low pressure preheater and an oil-cooler of some or other power plant respectively. The field testing results showed that their heat transfer coefficient with each types of enhancement heat transfer tubes were improved by 2.5% and 21%-45% comparing with copper smooth tube heat exchangers. Both basic and field experiment indicates that the steel tube with 2-side enhancement heat transfer is an ideal choice for heat exchanger reconstruction in no copper issue in power plants. 展开更多
关键词 spirally fluted tube ratchet tube with internal spiralgroove heat transfer enhancement copper corrosion low-pressure preheater oil cooler no copper in heating system
下载PDF
Thermo-flow characteristics and air flow field leading of the air-cooled condenser cell in a power plant 被引量:8
4
作者 ZHANG WanXi YANG LiJun +1 位作者 DU XiaoZe YANG YongPing 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第9期2475-2482,共8页
Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorat... Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorated thermo-flow performances of a condenser cell. It is of benefit to the design and operation optimization of the direct dry cooling system in a power plant to investigate the thermo-flow characteristics of the condenser cell and propose the flow leading measures of cooling air. On the basis of the representative configuration of the air-cooled condenser cell in a 600 MW direct dry cooling power plant, the computa- tional models of the air side fluid and heat flows are built, in which the actual fan blade geometric details are considered. Various flow field leading ways of cooling air are presented and the thermo-flow characteristics in the A-frame condenser cell and through the finned tube bundles are compared. Results show that the flow field leading measures can result in the increased volumetric flow rate and heat rejection, thus bringing on the improved performance of the condenser cell. The improvement of thermo-flow oerformances depends upon the geometric details of the flow guiding device. 展开更多
关键词 air-cooled condenser axial flow fan t'mned tube bundle flow and heat transfer characteristics flow field leading
原文传递