Under unbalanced source voltage supply, considerable output second harmonics and input low-order harmonics in 3-phase PWM current-source converters (PWM-CSC) are generated. This paper proposes a new deadbeat controlle...Under unbalanced source voltage supply, considerable output second harmonics and input low-order harmonics in 3-phase PWM current-source converters (PWM-CSC) are generated. This paper proposes a new deadbeat controller based on compensation for unbalanced source voltage and current. With the proposed scheme, the second harmonics of the output current are eliminated and low-order harmonics of the source current are reduced effectively. Simulation and experimental results con- firmed the feasibility of the proposed method.展开更多
This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (f...This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system.展开更多
In a smart grid, electric loads are supplied by various DC (direct current) power sources, such as solar cells or batteries. On the other hand, traditional AC (alternating current) loads like a directly connected ...In a smart grid, electric loads are supplied by various DC (direct current) power sources, such as solar cells or batteries. On the other hand, traditional AC (alternating current) loads like a directly connected induction motors will also be used. In the circumstances, a smart power conversion unit is one of key components, which can integrate these DC or AC apparatus and trade power among them. Authors have developed an integrated power converter based on a well-known circuit topology of flying capacitor multilevel converter. This paper describes the detail of the circuit topology and its characteristics depending on designed parameters. The achieved power quality is also verified by simulation study.展开更多
This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented ...This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented in the positive synchronously rotating reference frame and composed of a single proportional integral(PI) regulator and multi-frequency resonant controllers tuned at the frequencies of 2ω and 6ω,respectively.The experimental results,with the target of eliminating the active power oscillations and current harmonics on a prototype GC-VSC system,validate the feasibility of the proposed current control scheme during supply voltage imbalance and distortion.展开更多
The hybrid-HVDC topology,which consists of line-commutated-converter(LCC)and voltage source converter(VSC)and combines their advantages,has extensive application prospects.A hybrid-HVDC system,adopting VSC on rectifie...The hybrid-HVDC topology,which consists of line-commutated-converter(LCC)and voltage source converter(VSC)and combines their advantages,has extensive application prospects.A hybrid-HVDC system,adopting VSC on rectifier side and LCC on inverter side,is investigated,and its mathematic model is deduced.The commutation failure issue of the LCC converter in the hybrid-HVDC system is considered,and a novel coordinated control method is proposed to enhance the system commutation failure immunity.A voltage dependent voltage order limiter(VDVOL)is designed based on the constant DC voltage control on the rectifier side,and constant extinction angle backup control is introduced based on the constant DC current control with voltage dependent current order limiter(VDCOL)on the inverter side.The hybrid-HVDC system performances under normal operation state and fault state are simulated in the PSCAD/EMTDC.Then,system transient state performances with or without the proposed control methods under fault condition are further compared and analyzed.It is concluded that the proposed control method has the ability to effectively reduce the probability of commutation failure and improve the fault recovery performance of the hybrid-HVDC system.展开更多
基金Project (No. 50477033) supported by the National Nature ScienceFoundation of China
文摘Under unbalanced source voltage supply, considerable output second harmonics and input low-order harmonics in 3-phase PWM current-source converters (PWM-CSC) are generated. This paper proposes a new deadbeat controller based on compensation for unbalanced source voltage and current. With the proposed scheme, the second harmonics of the output current are eliminated and low-order harmonics of the source current are reduced effectively. Simulation and experimental results con- firmed the feasibility of the proposed method.
文摘This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system.
文摘In a smart grid, electric loads are supplied by various DC (direct current) power sources, such as solar cells or batteries. On the other hand, traditional AC (alternating current) loads like a directly connected induction motors will also be used. In the circumstances, a smart power conversion unit is one of key components, which can integrate these DC or AC apparatus and trade power among them. Authors have developed an integrated power converter based on a well-known circuit topology of flying capacitor multilevel converter. This paper describes the detail of the circuit topology and its characteristics depending on designed parameters. The achieved power quality is also verified by simulation study.
基金supported by the National Natural Science Foundation of China(No.50907057)the National High-Tech Research and Development Program (863) of China(No.2007AA05Z419)
文摘This paper proposes a current control scheme for a grid-connected pulse width modulator(PWM) voltage source converter(GC-VSC) under imbalanced and distorted supply voltage conditions.The control scheme is implemented in the positive synchronously rotating reference frame and composed of a single proportional integral(PI) regulator and multi-frequency resonant controllers tuned at the frequencies of 2ω and 6ω,respectively.The experimental results,with the target of eliminating the active power oscillations and current harmonics on a prototype GC-VSC system,validate the feasibility of the proposed current control scheme during supply voltage imbalance and distortion.
基金supported by the National High Technology Research and Development Program of China("863" Program)(Grant No.2013AA050105)the National Natural Science Foundation of China(Grant No.51177042)+1 种基金the Fundamental Research Funds for the Central Universities(Grant No.13QN03)2012 science and technology projects of State Grid Corporation of China(Grant No.XT71-12-015)
文摘The hybrid-HVDC topology,which consists of line-commutated-converter(LCC)and voltage source converter(VSC)and combines their advantages,has extensive application prospects.A hybrid-HVDC system,adopting VSC on rectifier side and LCC on inverter side,is investigated,and its mathematic model is deduced.The commutation failure issue of the LCC converter in the hybrid-HVDC system is considered,and a novel coordinated control method is proposed to enhance the system commutation failure immunity.A voltage dependent voltage order limiter(VDVOL)is designed based on the constant DC voltage control on the rectifier side,and constant extinction angle backup control is introduced based on the constant DC current control with voltage dependent current order limiter(VDCOL)on the inverter side.The hybrid-HVDC system performances under normal operation state and fault state are simulated in the PSCAD/EMTDC.Then,system transient state performances with or without the proposed control methods under fault condition are further compared and analyzed.It is concluded that the proposed control method has the ability to effectively reduce the probability of commutation failure and improve the fault recovery performance of the hybrid-HVDC system.