A complementary metal-oxide-semiconductor transistor (CMOS) voltage-to-current(VTC)converter with high linearity for current-mode analog and digital integrated circuits is described. A high gain operational amplif...A complementary metal-oxide-semiconductor transistor (CMOS) voltage-to-current(VTC)converter with high linearity for current-mode analog and digital integrated circuits is described. A high gain operational amplifier (OPA) is utilized to form negative feedback. A proportional to absolute temperature (PTAT) current reference with transistors operated in a weak inversion is used as the bias circuit. The resistor and the OPA nonlinearity behavior are analyzed in detail. By optimizing parameters in OPA and adopting a small voltage coefficient polysilicon resistor as a linear device, a high linearity is achieved. The circuit is implemented in a standard 0. 6 μm CMOS technology. The low frequency gain of the OPA exceeds 90 dB. The test results indicate that the total harmonic distortion (THD)is 0. 000 2%. The common-mode input linearity range is 0 to 2. 6 V. Correspondingly, the output current range is 50 to 426μA. The sensitivity of the PTAT current reference to Vdd is approximately 0. 021 7. The chip consumes a power of less than 1.3 mW for a 5 V supply, and occupies an area of 0. 112 mm^2.展开更多
In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and v...In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and voltage total harmonic distortion (THD), when it is assumed that the harmonic voltages or the harmonic currents in a distribution network increases by connection of many DGs through the inverters. The analysis on the influence of DGs is carried out by using a standard analytical model of distribution network with DGs based on the practical data. The authors evaluate quantitatively the influence which harmonics generated from DGs has on the harmonics of the distribution network, and analyze visually about propagation of harmonics within the distribution network. In addition, the authors also verify about the restraint effect of the harmonics in the network scale by the active filters installation.展开更多
This paper investigates the usage of passive harmonic filters to mitigate harmonic distortions when two resonant points are present in a system caused by shunt capacitors used for power factor correction and bus volta...This paper investigates the usage of passive harmonic filters to mitigate harmonic distortions when two resonant points are present in a system caused by shunt capacitors used for power factor correction and bus voltage regulation. Six scenarios were investigated using DIgSILENT 14 power factor)' software. The investigations are with and without power factor correction and capacitors used to increase bus voltage. Passive harmonic filters are designed to reduce harmonic distortions at the PCC (point of common coupling) to fall within the IEEE 519 harmonic voltage and current limits caused by parallel resonance. The results of the case studies are analysed to evaluate the effectiveness of the filter design.展开更多
A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for th...A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for the prediction of the neutral-point current. A quality function was found to balance the neutral-point, and a metabolic on-times distribution factor was used as a predicator to minimize the quality function at each switching state. Simulation results show that the proposed method produces smaller ripples in tested signals compared with the established one, namely, 9.15% less in a total harmonic distortion(THD) of line-to-line voltage, 1.08% less in the THD of phase current, and 0.9 V less in the ripple of the neutral-point voltage. The obtained experimental results show that the main harmonics of the line-to-line voltage and the phase current in the proposed method are improved by 10 d B and 6 d B, respectively, and the ripple of neutral-point voltage is halved compared to the established one.展开更多
文摘A complementary metal-oxide-semiconductor transistor (CMOS) voltage-to-current(VTC)converter with high linearity for current-mode analog and digital integrated circuits is described. A high gain operational amplifier (OPA) is utilized to form negative feedback. A proportional to absolute temperature (PTAT) current reference with transistors operated in a weak inversion is used as the bias circuit. The resistor and the OPA nonlinearity behavior are analyzed in detail. By optimizing parameters in OPA and adopting a small voltage coefficient polysilicon resistor as a linear device, a high linearity is achieved. The circuit is implemented in a standard 0. 6 μm CMOS technology. The low frequency gain of the OPA exceeds 90 dB. The test results indicate that the total harmonic distortion (THD)is 0. 000 2%. The common-mode input linearity range is 0 to 2. 6 V. Correspondingly, the output current range is 50 to 426μA. The sensitivity of the PTAT current reference to Vdd is approximately 0. 021 7. The chip consumes a power of less than 1.3 mW for a 5 V supply, and occupies an area of 0. 112 mm^2.
文摘In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and voltage total harmonic distortion (THD), when it is assumed that the harmonic voltages or the harmonic currents in a distribution network increases by connection of many DGs through the inverters. The analysis on the influence of DGs is carried out by using a standard analytical model of distribution network with DGs based on the practical data. The authors evaluate quantitatively the influence which harmonics generated from DGs has on the harmonics of the distribution network, and analyze visually about propagation of harmonics within the distribution network. In addition, the authors also verify about the restraint effect of the harmonics in the network scale by the active filters installation.
文摘This paper investigates the usage of passive harmonic filters to mitigate harmonic distortions when two resonant points are present in a system caused by shunt capacitors used for power factor correction and bus voltage regulation. Six scenarios were investigated using DIgSILENT 14 power factor)' software. The investigations are with and without power factor correction and capacitors used to increase bus voltage. Passive harmonic filters are designed to reduce harmonic distortions at the PCC (point of common coupling) to fall within the IEEE 519 harmonic voltage and current limits caused by parallel resonance. The results of the case studies are analysed to evaluate the effectiveness of the filter design.
基金Project(61074018)supported by the National Natural Science Foundation of ChinaProject(2012kfjj06)supported by Hunan Province Key Laboratory of Smart Grids Operation and Control(Changsha University of Science and Technology),China
文摘A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for the prediction of the neutral-point current. A quality function was found to balance the neutral-point, and a metabolic on-times distribution factor was used as a predicator to minimize the quality function at each switching state. Simulation results show that the proposed method produces smaller ripples in tested signals compared with the established one, namely, 9.15% less in a total harmonic distortion(THD) of line-to-line voltage, 1.08% less in the THD of phase current, and 0.9 V less in the ripple of the neutral-point voltage. The obtained experimental results show that the main harmonics of the line-to-line voltage and the phase current in the proposed method are improved by 10 d B and 6 d B, respectively, and the ripple of neutral-point voltage is halved compared to the established one.