The removal of lead from ginseng ethanol extracts by a fixed-bed column filled with an adsorbent bearing amine and carboxyl groups was investigated. The Pb2+ content was determined by inductively coupled plasma mass s...The removal of lead from ginseng ethanol extracts by a fixed-bed column filled with an adsorbent bearing amine and carboxyl groups was investigated. The Pb2+ content was determined by inductively coupled plasma mass spectrometry. When the flowrate increased from 0.12 to 0.34 ml·min-1 , the column exhibited a marked increase in percentage of lead removal from 54.9% to 92.3%. Further increase in the flowrate did not bring evident changes to the lead removal, whereas an increase in the temperature could reinforce adsorption further, suggesting that the adsorption process was controlled by external film diffusion below the flowrate of 0.34 ml·min-1 , and by the intraparticle pore diffusion of lead ions when the flowrate exceeded it. A low remaining lead amount in extracts such as 0.11 mg·kg-1 (extracts powder) was achieved. The adsorbents also adsorbed effective constituents to some extent. But 88% of constituents adsorbed were taken off using a 70% ethanol aqueous solution.展开更多
Abstract: A joint solution model of variabk:-mass flow in two-phase region and fluid-solid coupling heat transfer, concerned about the charge process of variable-mass thermodynamic system, is built up and calculated...Abstract: A joint solution model of variabk:-mass flow in two-phase region and fluid-solid coupling heat transfer, concerned about the charge process of variable-mass thermodynamic system, is built up and calculated by the finite element method (FEM). The results are basically consistent with relative experimental data. The calculated average heat transfer coefficient reaches 1.7~105 W/(m2. K). When the equal percentage valve is used, the system needs the minimum requirements of valve control, but brings the highest construction cost. With the: decrease of initial steam pressure, the heat transfer intensity also weakens but the steam flow increases. With the initial water filling coefficient increasing or the temperature of steam supply decreasing, the amount of accumulative steam flow increases with the growth of steam pressure. When the pressure of steam supply drops, the steam flow gradient increases during the maximum opening period of control valve, and causes the maximum steam flow to increase.展开更多
基金Supported by the National'Natural Science Foundation of China (20976012, 20806009), and the Specialized Research Fund for the Doctoral Program of Higher Education (20070007055, 20091101110035).
文摘The removal of lead from ginseng ethanol extracts by a fixed-bed column filled with an adsorbent bearing amine and carboxyl groups was investigated. The Pb2+ content was determined by inductively coupled plasma mass spectrometry. When the flowrate increased from 0.12 to 0.34 ml·min-1 , the column exhibited a marked increase in percentage of lead removal from 54.9% to 92.3%. Further increase in the flowrate did not bring evident changes to the lead removal, whereas an increase in the temperature could reinforce adsorption further, suggesting that the adsorption process was controlled by external film diffusion below the flowrate of 0.34 ml·min-1 , and by the intraparticle pore diffusion of lead ions when the flowrate exceeded it. A low remaining lead amount in extracts such as 0.11 mg·kg-1 (extracts powder) was achieved. The adsorbents also adsorbed effective constituents to some extent. But 88% of constituents adsorbed were taken off using a 70% ethanol aqueous solution.
基金Project(20080431380) supported by China Postdoctoral Science Foundation
文摘Abstract: A joint solution model of variabk:-mass flow in two-phase region and fluid-solid coupling heat transfer, concerned about the charge process of variable-mass thermodynamic system, is built up and calculated by the finite element method (FEM). The results are basically consistent with relative experimental data. The calculated average heat transfer coefficient reaches 1.7~105 W/(m2. K). When the equal percentage valve is used, the system needs the minimum requirements of valve control, but brings the highest construction cost. With the: decrease of initial steam pressure, the heat transfer intensity also weakens but the steam flow increases. With the initial water filling coefficient increasing or the temperature of steam supply decreasing, the amount of accumulative steam flow increases with the growth of steam pressure. When the pressure of steam supply drops, the steam flow gradient increases during the maximum opening period of control valve, and causes the maximum steam flow to increase.