This paper proposed that the flow characteristic of electronic expansion valve should be adapted to the evaporator superheat gain to refrigerant flow rate under different working conditions. Two native methods of geom...This paper proposed that the flow characteristic of electronic expansion valve should be adapted to the evaporator superheat gain to refrigerant flow rate under different working conditions. Two native methods of geometry modeling of electronic expansion valve head were introduced. By analysis of them, some shortcoming was detected and a universal modeling method of electronic expansion valve head was put forward. Through this model, the flow characteristic of EEV and the influence factors can be investigated more deeply.展开更多
The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different uni...The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different units was investigated by varying the outdoor ambient temperature and compressor speed. Based on the test results, the effect of EEV opening on the indoor unit exit superheat was discussed. For the specified outdoor ambient temperature scope and the EEV opening, the superheats of indoor units decrease with the outdoor ambient temperature rising. Improper distribution of refrigerant into each indoor unit will causes excessive superheat difference between two indoor units. Suggestions were then given for the controlling of the superheat.展开更多
文摘This paper proposed that the flow characteristic of electronic expansion valve should be adapted to the evaporator superheat gain to refrigerant flow rate under different working conditions. Two native methods of geometry modeling of electronic expansion valve head were introduced. By analysis of them, some shortcoming was detected and a universal modeling method of electronic expansion valve head was put forward. Through this model, the flow characteristic of EEV and the influence factors can be investigated more deeply.
文摘The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different units was investigated by varying the outdoor ambient temperature and compressor speed. Based on the test results, the effect of EEV opening on the indoor unit exit superheat was discussed. For the specified outdoor ambient temperature scope and the EEV opening, the superheats of indoor units decrease with the outdoor ambient temperature rising. Improper distribution of refrigerant into each indoor unit will causes excessive superheat difference between two indoor units. Suggestions were then given for the controlling of the superheat.