This paper presents an analysis of planar magnetic element configurations in order to reduce capacitive couplings between the windings. The capacitive couplings between layers of planar magnetic elements introduce a s...This paper presents an analysis of planar magnetic element configurations in order to reduce capacitive couplings between the windings. The capacitive couplings between layers of planar magnetic elements introduce a stray capacitor which can conduct high frequency currents when high dv/dt voltage is applied. High frequency current may cause electromagnetic interference (EMI) and harmonic problems. The investigation and simulation results, both 2D and 3D Finite Element (FE) show the effect of shifting the planar layers in reduction of the capacitive couplings. The simulation results are compared with test results to validate the proposition.展开更多
文摘This paper presents an analysis of planar magnetic element configurations in order to reduce capacitive couplings between the windings. The capacitive couplings between layers of planar magnetic elements introduce a stray capacitor which can conduct high frequency currents when high dv/dt voltage is applied. High frequency current may cause electromagnetic interference (EMI) and harmonic problems. The investigation and simulation results, both 2D and 3D Finite Element (FE) show the effect of shifting the planar layers in reduction of the capacitive couplings. The simulation results are compared with test results to validate the proposition.