Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power tr...Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power transformers, and the differentiation from other sources of acoustic emission is of the utmost importance. This paper reports the development of a new sensor concept - a fiber laser sensor based on a phase-shifted chirped fiber grating - for the acoustic emission detection of incipient faults in oil-filled power transformers. These sensors can be placed in the inner surface of the transformer tank wall, not affecting the insulation integrity of the structure and improving fault detection and location. The performance of the sensing head is characterized and compared for different surrounding media: air, water, and oil. The results obtained indicate the feasibility of this sensing approach for the industrial development of practical solutions.展开更多
A new method of measuring gas pressure in vacuum insulation panels(VIPs)is reported in this study,which provides a fast and efficient quality control option of production.Although there are different methods of measur...A new method of measuring gas pressure in vacuum insulation panels(VIPs)is reported in this study,which provides a fast and efficient quality control option of production.Although there are different methods of measuring gas pressure for VIPs,connecting an internal measurement gauge to external data acquisition units is problematic.The thin high barrier film covering the panel’s core usually prevents external electrical wires or mechanical devices being connected to the inside of the VIPs.To solve this problem,a micro capacitive pressure sensor with 0 to 250 Pa detection range is developed to detect the vacuum pressure.The sensor has high linearity and a sensitivity of 10 mV/Pa.Moreover,through the communication mode study,an ultrasound communications system for VIPs is designed.It shows from operation that this system is stable and reliable,and quick for communication speed.This new method enables the quality detection of VIPs to be completed within 1 second.The minimum detectable pressure of VIPs is below 1 Pa,and the measurement error can be controlled around 5%.展开更多
文摘Acoustic emission monitoring is often used in the diagnosis of electrical and mechanical incipient faults in the high voltage apparatus. Partial discharges are a major source of insulation failure in electric power transformers, and the differentiation from other sources of acoustic emission is of the utmost importance. This paper reports the development of a new sensor concept - a fiber laser sensor based on a phase-shifted chirped fiber grating - for the acoustic emission detection of incipient faults in oil-filled power transformers. These sensors can be placed in the inner surface of the transformer tank wall, not affecting the insulation integrity of the structure and improving fault detection and location. The performance of the sensing head is characterized and compared for different surrounding media: air, water, and oil. The results obtained indicate the feasibility of this sensing approach for the industrial development of practical solutions.
基金supported by the Science and Technology Projects of Fujian Province of China(Grant No.2010H6025)Science and Technology Projects of Xiamen City of China(Grant No.3502Z20103012)
文摘A new method of measuring gas pressure in vacuum insulation panels(VIPs)is reported in this study,which provides a fast and efficient quality control option of production.Although there are different methods of measuring gas pressure for VIPs,connecting an internal measurement gauge to external data acquisition units is problematic.The thin high barrier film covering the panel’s core usually prevents external electrical wires or mechanical devices being connected to the inside of the VIPs.To solve this problem,a micro capacitive pressure sensor with 0 to 250 Pa detection range is developed to detect the vacuum pressure.The sensor has high linearity and a sensitivity of 10 mV/Pa.Moreover,through the communication mode study,an ultrasound communications system for VIPs is designed.It shows from operation that this system is stable and reliable,and quick for communication speed.This new method enables the quality detection of VIPs to be completed within 1 second.The minimum detectable pressure of VIPs is below 1 Pa,and the measurement error can be controlled around 5%.