A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair ...A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair consists of one stimulating electrode and one recording electrode. Supported by the peripheral circuits, four electrode states to study the bioelectrical signal of biological tissue or slice cultured in-vitro on the surface of the electrodes can be realized through each pair of electrodes. The four electrode states are stimulation, recording, stimulation and recording simultaneously, and isolation. The state of each pair of working electrodes can be arbitrarily controlled according to actual needs. The MEAs are fabricated in printed circuit board (PCB) technology. The total area of the PCB-based MEA is 49 mm × 49 mm. The impedance measurement of MEA is carried out in 0.9% sodium chloride solution at room temperature by means of 2-point measurements with an Agilent LCR meter, and the test signal for the impedance measurement is sinusoidal (AC voltage 50 mV, sweeping frequency 20 Hz to 10 kHz). The electrode impedance is between 200 and 3 kΩ while the frequency is between 500 and 1 000 Hz. The electrode impedance magnitude is inversely proportional to the frequency. Experiments of toad sciatic nerve in-vitro stimulation and recording and signal regeneration between isolated toad sciatic nerves are carried out on the PCB-based MEA. The results show that the MEA can be used for bioelectrical signal stimulation, recording, stimulation and recording simultaneously, and isolation of biological tissues or slices in-vitro.展开更多
Based on the 4-channel neural signal regeneration system which is realized by using discrete devices and successfully used for in-vivo experiments on rats and rabbits, a single channel neural signal regeneration integ...Based on the 4-channel neural signal regeneration system which is realized by using discrete devices and successfully used for in-vivo experiments on rats and rabbits, a single channel neural signal regeneration integrated circuit (IC)is designed and realized in CSMC ' s 0. 6 μm CMOS ( complementary metal-oxide-semiconductor transistor ) technology. The IC consists of a neural signal detection circuit with an adjustable gain, a buffer, and a function electrical stimulation (FES) circuit. The neural signal regenerating IC occupies a die area of 1.42 mm × 1.34 mm. Under a dual supply voltage of ±2. 5 V, the DC power consumption is less than 10 mW. The on-wafer measurement results are as follows: the output resistor is 118 ml), the 3 dB bandwidth is greater than 30 kHz, and the gain can be variable from 50 to 90 dB. The circuit is used for in-vivo experiments on the rat' s sciatic nerve as well as on the spinal cord with the cuff type electrode array and the twin-needle electrode. The neural signal is successfully regenerated both on a rat' s sciatic nerve bundle and on the spinal cord.展开更多
The module for function electrical stimulation (FES) of neurons is designed for the research of the neural function regeneration microelectronic system, which is an in-body embedded micro module. It is implemented b...The module for function electrical stimulation (FES) of neurons is designed for the research of the neural function regeneration microelectronic system, which is an in-body embedded micro module. It is implemented by using discrete devices at first and characterized in vitro. The module is used to stimulate sciatic nerve and spinal cord of rats and rabbits for in-vivo real-time experiments of the neural function regeneration system. Based on the module, a four channel module for the FES of neurons is designed for 12 sites cuff electrode or 10 sites shaft electrode. Three animal experiments with total five rats and two rabbits were made. In the in-vivo experiment, the neural signals including spontaneous and imitated were regenerated by the module. The stimulating signal was used to drive sciatic nerve and spinal cord of rats and rabbits, successfully caused them twitch in different parts of their bodies, such as legs, tails, and fingers. This testifies that the neural function regeneration system can regenerate the neural signals.展开更多
基金The National Natural Science Foundation of China(No. 61076118, 90307013, 90707005)the Natural Science Foundation of Jiangsu Province (No. BK2008032)Special Foundation and Open Foundation of the State Key Laboratory of Bioelectronics of Southeast University
文摘A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair consists of one stimulating electrode and one recording electrode. Supported by the peripheral circuits, four electrode states to study the bioelectrical signal of biological tissue or slice cultured in-vitro on the surface of the electrodes can be realized through each pair of electrodes. The four electrode states are stimulation, recording, stimulation and recording simultaneously, and isolation. The state of each pair of working electrodes can be arbitrarily controlled according to actual needs. The MEAs are fabricated in printed circuit board (PCB) technology. The total area of the PCB-based MEA is 49 mm × 49 mm. The impedance measurement of MEA is carried out in 0.9% sodium chloride solution at room temperature by means of 2-point measurements with an Agilent LCR meter, and the test signal for the impedance measurement is sinusoidal (AC voltage 50 mV, sweeping frequency 20 Hz to 10 kHz). The electrode impedance is between 200 and 3 kΩ while the frequency is between 500 and 1 000 Hz. The electrode impedance magnitude is inversely proportional to the frequency. Experiments of toad sciatic nerve in-vitro stimulation and recording and signal regeneration between isolated toad sciatic nerves are carried out on the PCB-based MEA. The results show that the MEA can be used for bioelectrical signal stimulation, recording, stimulation and recording simultaneously, and isolation of biological tissues or slices in-vitro.
基金The National Natural Science Foundation of China(No.90307013,90707005)
文摘Based on the 4-channel neural signal regeneration system which is realized by using discrete devices and successfully used for in-vivo experiments on rats and rabbits, a single channel neural signal regeneration integrated circuit (IC)is designed and realized in CSMC ' s 0. 6 μm CMOS ( complementary metal-oxide-semiconductor transistor ) technology. The IC consists of a neural signal detection circuit with an adjustable gain, a buffer, and a function electrical stimulation (FES) circuit. The neural signal regenerating IC occupies a die area of 1.42 mm × 1.34 mm. Under a dual supply voltage of ±2. 5 V, the DC power consumption is less than 10 mW. The on-wafer measurement results are as follows: the output resistor is 118 ml), the 3 dB bandwidth is greater than 30 kHz, and the gain can be variable from 50 to 90 dB. The circuit is used for in-vivo experiments on the rat' s sciatic nerve as well as on the spinal cord with the cuff type electrode array and the twin-needle electrode. The neural signal is successfully regenerated both on a rat' s sciatic nerve bundle and on the spinal cord.
基金The National Natural Science Foundation of China(No69825101,90377013)
文摘The module for function electrical stimulation (FES) of neurons is designed for the research of the neural function regeneration microelectronic system, which is an in-body embedded micro module. It is implemented by using discrete devices at first and characterized in vitro. The module is used to stimulate sciatic nerve and spinal cord of rats and rabbits for in-vivo real-time experiments of the neural function regeneration system. Based on the module, a four channel module for the FES of neurons is designed for 12 sites cuff electrode or 10 sites shaft electrode. Three animal experiments with total five rats and two rabbits were made. In the in-vivo experiment, the neural signals including spontaneous and imitated were regenerated by the module. The stimulating signal was used to drive sciatic nerve and spinal cord of rats and rabbits, successfully caused them twitch in different parts of their bodies, such as legs, tails, and fingers. This testifies that the neural function regeneration system can regenerate the neural signals.