Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system ...Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system with electromagnetic system will cause EMR malfunction. The nonlinear dynamics model of armature systems was studied by considering electro- magnetic attraction force and opposite mechanical force in this paper. Angular displacements of armature under different sinu- soidal vibration conditions are solved in order to obtain the failure mode result from armature system. Vibration tests showed the presented analyzing method is suitable for EMR. The conclusions are instructive for increasing vibration resistance of armature systems of EMR, and are significant for reliability design of switch apparatus.展开更多
Electroencephalogram (EEG) is an efficient tool in exploring human brains. It plays a very important role in diagnosis of disorders related to epilepsy and development of new interaction techniques between machines an...Electroencephalogram (EEG) is an efficient tool in exploring human brains. It plays a very important role in diagnosis of disorders related to epilepsy and development of new interaction techniques between machines and human beings,namely,brain-computer interface (BCI). The purpose of this review is to illustrate the recent researches in EEG processing and EEG-based BCI. First,we outline several methods in removing artifacts from EEGs,and classical algorithms for fatigue detection are discussed. Then,two BCI paradigms including motor imagery and steady-state motion visual evoked potentials (SSMVEP) produced by oscillating Newton's rings are introduced. Finally,BCI systems including wheelchair controlling and electronic car navigation are elaborated. As a new technique to control equipments,BCI has promising potential in rehabilitation of disorders in central nervous system,such as stroke and spinal cord injury,treatment of attention deficit hyperactivity disorder (ADHD) in children and development of novel games such as brain-controlled auto racings.展开更多
AIM: To investigate sensations to multimodal pain stimulation in the metaplastic and normal parts of the esophagus in patients with Barrett’s esophagus (BE). METHODS: Fifteen patients with BE and 15 age-matched healt...AIM: To investigate sensations to multimodal pain stimulation in the metaplastic and normal parts of the esophagus in patients with Barrett’s esophagus (BE). METHODS: Fifteen patients with BE and 15 age-matched healthy volunteers were subjected to mechanical, thermal and electrical pain stimuli of the esophagus. Both the metaplastic part and the normal part (4 and 14 cm, respectively, above the esophago-gastric junction) were examined. At sensory thresholds the stimulation intensity, referred pain areas, and evoked brain potentials were recorded. RESULTS: Patients were hyposensitive to heat stimulation both in the metaplastic part [median stimulation time to reach the pain detection threshold: 15 (12-34) s vs 14 (6-23) s in controls; F = 4.5, P = 0.04] and the normal part of the esophagus [median 17 (6-32) s vs 13 (8-20) s in controls; F = 6.2, P = 0.02]. Furthermore, patients were hyposensitive in the metaplastic part of the esophagus to mechanical distension [median volume at moderate pain: 50 (20-50) mL vs 33 (13-50) mL in controls; F = 5.7, P = 0.02]. No indication of central nervous system abnormalities was present, as responses were comparable between groups to electrical pain stimuli in the metaplastic part [median current evoking moderate pain: 13 (6-26) mA vs 12 (9-24) mA in controls; F = 0.1, P = 0.7], and in the normal part of the esophagus [median current evoking moderate pain: 9 (6-16) mA, vs 11 (5-11) mA in controls; F = 3.4, P = 0.07]. Furthermore, no differences were seen for the referred pain areas (P-values all > 0.3) or latencies and amplitudes for the evoked brain potentials (P-values all > 0.1). CONCLUSION: Patients with BE are hyposensitive both in the metaplastic and normal part of esophagus likely as a result of abnormalities affecting peripheral nerve pathways.展开更多
基金Project (No. FEBQ24409102) supported by the Space Technology Innovation Fund, China
文摘Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system with electromagnetic system will cause EMR malfunction. The nonlinear dynamics model of armature systems was studied by considering electro- magnetic attraction force and opposite mechanical force in this paper. Angular displacements of armature under different sinu- soidal vibration conditions are solved in order to obtain the failure mode result from armature system. Vibration tests showed the presented analyzing method is suitable for EMR. The conclusions are instructive for increasing vibration resistance of armature systems of EMR, and are significant for reliability design of switch apparatus.
基金National Natural Science Foundation of China(No.51005176)Research Fund for the Doctoral Program of Higher Education of China(No.20100201120003)
文摘Electroencephalogram (EEG) is an efficient tool in exploring human brains. It plays a very important role in diagnosis of disorders related to epilepsy and development of new interaction techniques between machines and human beings,namely,brain-computer interface (BCI). The purpose of this review is to illustrate the recent researches in EEG processing and EEG-based BCI. First,we outline several methods in removing artifacts from EEGs,and classical algorithms for fatigue detection are discussed. Then,two BCI paradigms including motor imagery and steady-state motion visual evoked potentials (SSMVEP) produced by oscillating Newton's rings are introduced. Finally,BCI systems including wheelchair controlling and electronic car navigation are elaborated. As a new technique to control equipments,BCI has promising potential in rehabilitation of disorders in central nervous system,such as stroke and spinal cord injury,treatment of attention deficit hyperactivity disorder (ADHD) in children and development of novel games such as brain-controlled auto racings.
基金Supported by "Hertha Christensens Fond" and "The Danish Agency for Science, Technology and Innovation"
文摘AIM: To investigate sensations to multimodal pain stimulation in the metaplastic and normal parts of the esophagus in patients with Barrett’s esophagus (BE). METHODS: Fifteen patients with BE and 15 age-matched healthy volunteers were subjected to mechanical, thermal and electrical pain stimuli of the esophagus. Both the metaplastic part and the normal part (4 and 14 cm, respectively, above the esophago-gastric junction) were examined. At sensory thresholds the stimulation intensity, referred pain areas, and evoked brain potentials were recorded. RESULTS: Patients were hyposensitive to heat stimulation both in the metaplastic part [median stimulation time to reach the pain detection threshold: 15 (12-34) s vs 14 (6-23) s in controls; F = 4.5, P = 0.04] and the normal part of the esophagus [median 17 (6-32) s vs 13 (8-20) s in controls; F = 6.2, P = 0.02]. Furthermore, patients were hyposensitive in the metaplastic part of the esophagus to mechanical distension [median volume at moderate pain: 50 (20-50) mL vs 33 (13-50) mL in controls; F = 5.7, P = 0.02]. No indication of central nervous system abnormalities was present, as responses were comparable between groups to electrical pain stimuli in the metaplastic part [median current evoking moderate pain: 13 (6-26) mA vs 12 (9-24) mA in controls; F = 0.1, P = 0.7], and in the normal part of the esophagus [median current evoking moderate pain: 9 (6-16) mA, vs 11 (5-11) mA in controls; F = 3.4, P = 0.07]. Furthermore, no differences were seen for the referred pain areas (P-values all > 0.3) or latencies and amplitudes for the evoked brain potentials (P-values all > 0.1). CONCLUSION: Patients with BE are hyposensitive both in the metaplastic and normal part of esophagus likely as a result of abnormalities affecting peripheral nerve pathways.