The performance of a flotation circuit is largely the result of the operator's response to visual clues. This includes manipulation of the gas input and how it is distributed to cells in a bank. A new gas dispersi...The performance of a flotation circuit is largely the result of the operator's response to visual clues. This includes manipulation of the gas input and how it is distributed to cells in a bank. A new gas dispersion technology was presented which was conducted to perform characterization tests in Outokumpu 30 m3 and 50 m3 flotation cells installed at Thompson Vale's concentrator, and subsequent data analysis. The experimental program was designed to establish "as-found" baseline conditions for each cell of the two-parallel banks in the scavenger-cleaner and recleaner circuit, to select and characterize one typical cell in the two banks with either different frother concentrations or different air flow rates, and establish what variables can be manipulated in future characterization work. A three-parameter model was developed in order to link the bubble size and frother concentration. This relationship can be used to correlate gas dispersion change to improved metallurgical performance.展开更多
In this paper, virtual instnnnent technology is applied in the development of an electric parameter measta'ement system for mobile power stations. Virtual inset technology is used to lmasure and analyze electric para...In this paper, virtual instnnnent technology is applied in the development of an electric parameter measta'ement system for mobile power stations. Virtual inset technology is used to lmasure and analyze electric parameters of mobile power stations. The whole measurement system is mmpmed of computer, data acquisition card and LabView virtual instnnnent platform. It can be used to monitor, record, and analyze electric parameters of sinusoidal alternating ciroait These parameters include voltage, effective value of ctaxent, phase differences, power, and etc. Experimental results show that this virtual measuring device satisfy the requirement of mobile power station montoring anti dynamic property analysis. Hardware and software design of the system will be discussed in detail.展开更多
In this paper, different electrical measurement and operation methods of resistive random access memory (RRAM) have been summarized, including voltage sweeping mode (VSM), current sweeping mode (CSM), co lstant ...In this paper, different electrical measurement and operation methods of resistive random access memory (RRAM) have been summarized, including voltage sweeping mode (VSM), current sweeping mode (CSM), co lstant current stress (CCS), constant voltage stress (CVS), rectangular pulse mode (RPM), and triangle pulse mode (TPM). Meanwhile, the effects of these meas- urement methods on the forming, set, reset and read operation as well as endurance performance have been compared. Finally, their respective controllability of various resistive switching parameters have been summar zeal and analyzed.展开更多
基金Project(2012BAB14B05)supported by National Key Technology Research and Development Program of the Ministry of Science and Technology of China
文摘The performance of a flotation circuit is largely the result of the operator's response to visual clues. This includes manipulation of the gas input and how it is distributed to cells in a bank. A new gas dispersion technology was presented which was conducted to perform characterization tests in Outokumpu 30 m3 and 50 m3 flotation cells installed at Thompson Vale's concentrator, and subsequent data analysis. The experimental program was designed to establish "as-found" baseline conditions for each cell of the two-parallel banks in the scavenger-cleaner and recleaner circuit, to select and characterize one typical cell in the two banks with either different frother concentrations or different air flow rates, and establish what variables can be manipulated in future characterization work. A three-parameter model was developed in order to link the bubble size and frother concentration. This relationship can be used to correlate gas dispersion change to improved metallurgical performance.
文摘In this paper, virtual instnnnent technology is applied in the development of an electric parameter measta'ement system for mobile power stations. Virtual inset technology is used to lmasure and analyze electric parameters of mobile power stations. The whole measurement system is mmpmed of computer, data acquisition card and LabView virtual instnnnent platform. It can be used to monitor, record, and analyze electric parameters of sinusoidal alternating ciroait These parameters include voltage, effective value of ctaxent, phase differences, power, and etc. Experimental results show that this virtual measuring device satisfy the requirement of mobile power station montoring anti dynamic property analysis. Hardware and software design of the system will be discussed in detail.
基金supported by the National Natural Science Foundation of China(Grant Nos.61322408,61221004,61422407,61334007,61474136,61274091,61376112,61306117,61106119,and 61106082)National Basic Research Program of China(Grant No.2011CBA00602)National High Technology Research and Development Program of China(Grant Nos.2014AA032900,2013AA030801,2011AA010401 and 2011AA-010402)
文摘In this paper, different electrical measurement and operation methods of resistive random access memory (RRAM) have been summarized, including voltage sweeping mode (VSM), current sweeping mode (CSM), co lstant current stress (CCS), constant voltage stress (CVS), rectangular pulse mode (RPM), and triangle pulse mode (TPM). Meanwhile, the effects of these meas- urement methods on the forming, set, reset and read operation as well as endurance performance have been compared. Finally, their respective controllability of various resistive switching parameters have been summar zeal and analyzed.