期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
CA488型发动机清洗节气门体后怠速过高故障排除
1
作者 张丹颖 《汽车维修》 2004年第3期27-27,共1页
关键词 汽车维修 发动机故障 节气门 怠速过高 故障排除 电气系统测量 气门调节
下载PDF
Resistivity in Formation and Decomposition of Natural Gas Hydrate in Porous Medium 被引量:14
2
作者 李淑霞 夏晞冉 +2 位作者 玄建 刘亚平 李清平 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2010年第1期39-42,共4页
A new one-dimensional system for resistivity measurement for natural gas hydrate(NGH)exploitation is designed,which is used to study the formation and decomposition processes of NGH.The experimental results verify the... A new one-dimensional system for resistivity measurement for natural gas hydrate(NGH)exploitation is designed,which is used to study the formation and decomposition processes of NGH.The experimental results verify the feasibility of the measurement method,especially in monitoring the nucleation and growth of the NGH. Isovolumetric formation experiment of NGH is performed at 2°C and 7.8 MPa.Before the NGH formation,the initial resistivity is measured to be 4-7Ω·m,which declines to the minimum value of 2-3Ω·m when NGH begins to nucleate after the pressure is reduced to 3.3 MPa.As the NGH grows,the resistivity increases to a great extent,and finally it keeps at 11-13Ω·m,indicating the completion of the formation process.The NGH decomposition experiment is then performed.When the outlet pressure decreases,NGH begins to decompose,accordingly,the resistivity declines gradually,and is at 5-9Ω·m when the decomposition process ends,which is slightly higher than the resistivity value before the formation of NGH.The occurrence and distribution uniformity of NGH are determined by the distribution and magnitude of the resistivity measured on an one-dimensional sand-packed model.This study tackles the accurate estimation for the distribution of NGH in porous medium,and provides an experimental basis for further study on NGH exploitation in the future. 展开更多
关键词 RESISTIVITY natural gas hydrate FORMATION decomposition by depressurization
下载PDF
Electric Parameter Measurement System Based on Virtual Instrument
3
作者 戴文 林青 +1 位作者 魏淑艳 曹明革 《Journal of Measurement Science and Instrumentation》 CAS 2011年第1期9-12,共4页
In this paper, virtual instnnnent technology is applied in the development of an electric parameter measta'ement system for mobile power stations. Virtual inset technology is used to lmasure and analyze electric para... In this paper, virtual instnnnent technology is applied in the development of an electric parameter measta'ement system for mobile power stations. Virtual inset technology is used to lmasure and analyze electric parameters of mobile power stations. The whole measurement system is mmpmed of computer, data acquisition card and LabView virtual instnnnent platform. It can be used to monitor, record, and analyze electric parameters of sinusoidal alternating ciroait These parameters include voltage, effective value of ctaxent, phase differences, power, and etc. Experimental results show that this virtual measuring device satisfy the requirement of mobile power station montoring anti dynamic property analysis. Hardware and software design of the system will be discussed in detail. 展开更多
关键词 virtual inset electric parameter measnt data acquisition mobile power station
下载PDF
Partial Discharge Measurement of OCP-Tapes in Rotating Electrical Machines
4
作者 Philipp Pretis Jurgen Fabian +4 位作者 Christof Sumereder Michael Muhr Helmut Heinle Christoph Richter Bernhard Brandstatter 《Journal of Energy and Power Engineering》 2014年第8期1443-1448,共6页
Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the u... Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the user are interested in the results of PD measurements. However, PDs hardly represent the cause of the failure, more likely they are claimed as the outcome of a failure. This paper deals with the insulation of a 6 kV electrical machine, whereas PD measurements were carried out at a single stator from wound coils. During manufacturing, these coils were equipped with different materials for the OCP (outer corona protection). Using different PD measurement systems and different bandwidths, investigations of the PD behavior of the coils were carried out. Additionally, the surface resistivity of the corona protection was determined. As a result, conclusions for the correlations between the resistance of the OCP as well as the PD behavior are stated. Furthermore, the influence of using different measurement systems, different measuring circuits, and different bandwidths is shown. 展开更多
关键词 PD behavior rotating electrical machine OCP-tapes PD measurement systems PD bandwidths
下载PDF
Realization of low contact resistance close to theoretical limit in graphene transistors 被引量:5
5
作者 Hua Zhong Zhiyong Zhang Bingyan Chen Haitao Xu Dangming Yu Le Huang Lianmao Peng 《Nano Research》 SCIE EI CAS CSCD 2015年第5期1669-1679,共11页
Realizing low contact resistance between graphene and metal electrodes remains a well-known challenge for building high-performance graphene devices. In this work, we attempt to reduce the contact resistance in graphe... Realizing low contact resistance between graphene and metal electrodes remains a well-known challenge for building high-performance graphene devices. In this work, we attempt to reduce the contact resistance in graphene transistors and further explore the resistance limit between graphene and metal contacts. The Pd/graphene contact resistance at room temperature is reduced below the 100 Ω·μm level both on mechanically exfoliated and chemical-vapor-deposition graphene by adopting high-purity palladium and high-quality graphene and controlling the fabrication process to not contaminate the interface. After excluding the parasitic series resistances from the measurement system and electrodes, the retrieved contact resistance is shown to be systematically and statistically less than 100 Ω·μm, with a minimum value of 69 Ω·μm, which is very close to the theoretical limit. Furthermore, the contact resistance shows no clear dependence on temperature in the range of 77-300 K; this is attributed to the saturation of carrier injection efficiency between graphene and Pd owing to the high quality of the graphene samples used, which have a sufficiently long carrier mean-free-path. 展开更多
关键词 graphene field-effect transistors contact resistance metal-graphene interface transfer length method
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部