Characteristic period is an important parameter of the seismic design response spectrum. There is important theoretical significance and engineering application value to the study of the characteristic period of seism...Characteristic period is an important parameter of the seismic design response spectrum. There is important theoretical significance and engineering application value to the study of the characteristic period of seismic design response spectrum of ultra high voltage (UHV) electrical equipment. In this paper, 1448 horizontal earthquake records within the world scope including the United States and Japan for Site Class m were analyzed. Results show that both magnitude and epicentral distance have great influence on the characteristic period. About 80 % of characteristic periods of strong earthquake records are about 0. 9s. Statistical analysis was conducted on the seismic hazard assessment results of 312 projects of China in recent years, and it is found that about 70 % of characteristic periods are about 0. 9s. Combined with the related code comparison and analysis, it is suggested that the characteristic period of the seismic design response spectrmn of UHV electrical equipment should select 0. 9s in order to effectively guarantee the seismic safety of UHV electrical equipment.展开更多
It is of great significance to make comparative analyses of seismic fortification criteria at home and abroad for improving the anti-seismic capability of electrical equipment and revising the relevant national standa...It is of great significance to make comparative analyses of seismic fortification criteria at home and abroad for improving the anti-seismic capability of electrical equipment and revising the relevant national standards.A brief overview of American,Japanese,IEC standards and Chinese seismic design codes for electrical equipment is presented.Differences between these seismic fortification standards of electrical equipment are compared and analyzed in respect of the goal and level of seismic fortification and the seismic design spectrum.The advantages and disadvantages of Chinese standards are pointed out.Through learning from foreign experience on the determination of seismic fortification standards,recommendations are made for the improvement and revision of Chinese seismic fortification standards for electrical equipment.展开更多
This paper presents suggestions in aspects(which should meet the standards) such as alarm indication, system setup and system security during the designing process of alarm system in medical electrical equipment, whic...This paper presents suggestions in aspects(which should meet the standards) such as alarm indication, system setup and system security during the designing process of alarm system in medical electrical equipment, which can be used as a reference for manufacturers.展开更多
基金founded by the Earthquake Science and Technology Spark Plan of China(XH12063)
文摘Characteristic period is an important parameter of the seismic design response spectrum. There is important theoretical significance and engineering application value to the study of the characteristic period of seismic design response spectrum of ultra high voltage (UHV) electrical equipment. In this paper, 1448 horizontal earthquake records within the world scope including the United States and Japan for Site Class m were analyzed. Results show that both magnitude and epicentral distance have great influence on the characteristic period. About 80 % of characteristic periods of strong earthquake records are about 0. 9s. Statistical analysis was conducted on the seismic hazard assessment results of 312 projects of China in recent years, and it is found that about 70 % of characteristic periods are about 0. 9s. Combined with the related code comparison and analysis, it is suggested that the characteristic period of the seismic design response spectrmn of UHV electrical equipment should select 0. 9s in order to effectively guarantee the seismic safety of UHV electrical equipment.
基金funded by the special project of Spark Program of Earthquake Sciences (Serial number:XH12063)
文摘It is of great significance to make comparative analyses of seismic fortification criteria at home and abroad for improving the anti-seismic capability of electrical equipment and revising the relevant national standards.A brief overview of American,Japanese,IEC standards and Chinese seismic design codes for electrical equipment is presented.Differences between these seismic fortification standards of electrical equipment are compared and analyzed in respect of the goal and level of seismic fortification and the seismic design spectrum.The advantages and disadvantages of Chinese standards are pointed out.Through learning from foreign experience on the determination of seismic fortification standards,recommendations are made for the improvement and revision of Chinese seismic fortification standards for electrical equipment.
文摘This paper presents suggestions in aspects(which should meet the standards) such as alarm indication, system setup and system security during the designing process of alarm system in medical electrical equipment, which can be used as a reference for manufacturers.