In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get the...In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get thermal flow field of a ACC under different conditions in low velocity wind tunnel,at the same time,the recirculation ratio at cooling tower was measured,so the relationship between flow field characteristics and recirculation ratio of cooling tower can be discussed. From the results we can see that the flow field configuration around cooling tower has great effects on average recirculation ratio under cooling tower. The eddy formed around cooling tower is a key reason that recirculation produces. The eddy intensity relates to velocity magnitude and direction angle,and the configuration of eddy lies on the geometry size of cooling tower. So changing the flow field configuration around cooling tower reasonably can decrease recirculation ratio under cooling tower,and heat dispel effect of ACC can also be improved.展开更多
This paper proposed that the flow characteristic of electronic expansion valve should be adapted to the evaporator superheat gain to refrigerant flow rate under different working conditions. Two native methods of geom...This paper proposed that the flow characteristic of electronic expansion valve should be adapted to the evaporator superheat gain to refrigerant flow rate under different working conditions. Two native methods of geometry modeling of electronic expansion valve head were introduced. By analysis of them, some shortcoming was detected and a universal modeling method of electronic expansion valve head was put forward. Through this model, the flow characteristic of EEV and the influence factors can be investigated more deeply.展开更多
Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorat...Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorated thermo-flow performances of a condenser cell. It is of benefit to the design and operation optimization of the direct dry cooling system in a power plant to investigate the thermo-flow characteristics of the condenser cell and propose the flow leading measures of cooling air. On the basis of the representative configuration of the air-cooled condenser cell in a 600 MW direct dry cooling power plant, the computa- tional models of the air side fluid and heat flows are built, in which the actual fan blade geometric details are considered. Various flow field leading ways of cooling air are presented and the thermo-flow characteristics in the A-frame condenser cell and through the finned tube bundles are compared. Results show that the flow field leading measures can result in the increased volumetric flow rate and heat rejection, thus bringing on the improved performance of the condenser cell. The improvement of thermo-flow oerformances depends upon the geometric details of the flow guiding device.展开更多
文摘In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get thermal flow field of a ACC under different conditions in low velocity wind tunnel,at the same time,the recirculation ratio at cooling tower was measured,so the relationship between flow field characteristics and recirculation ratio of cooling tower can be discussed. From the results we can see that the flow field configuration around cooling tower has great effects on average recirculation ratio under cooling tower. The eddy formed around cooling tower is a key reason that recirculation produces. The eddy intensity relates to velocity magnitude and direction angle,and the configuration of eddy lies on the geometry size of cooling tower. So changing the flow field configuration around cooling tower reasonably can decrease recirculation ratio under cooling tower,and heat dispel effect of ACC can also be improved.
文摘This paper proposed that the flow characteristic of electronic expansion valve should be adapted to the evaporator superheat gain to refrigerant flow rate under different working conditions. Two native methods of geometry modeling of electronic expansion valve head were introduced. By analysis of them, some shortcoming was detected and a universal modeling method of electronic expansion valve head was put forward. Through this model, the flow characteristic of EEV and the influence factors can be investigated more deeply.
基金supported by the National Basic Research Program of China (973 Program)(Grant No.2009CB219804)the National Scientific and Technical Supporting Program of China(Grant No.2011BAA04B02)
文摘Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorated thermo-flow performances of a condenser cell. It is of benefit to the design and operation optimization of the direct dry cooling system in a power plant to investigate the thermo-flow characteristics of the condenser cell and propose the flow leading measures of cooling air. On the basis of the representative configuration of the air-cooled condenser cell in a 600 MW direct dry cooling power plant, the computa- tional models of the air side fluid and heat flows are built, in which the actual fan blade geometric details are considered. Various flow field leading ways of cooling air are presented and the thermo-flow characteristics in the A-frame condenser cell and through the finned tube bundles are compared. Results show that the flow field leading measures can result in the increased volumetric flow rate and heat rejection, thus bringing on the improved performance of the condenser cell. The improvement of thermo-flow oerformances depends upon the geometric details of the flow guiding device.