一种新型太阳能喷射式电热(冷)联供系统的热力性能及经济性分析 被引量:2
1
作者 罗迟 孙培杰 +2 位作者 章恺 吕小静 翁一武 《动力工程学报》 CAS CSCD 北大核心 2021年第8期684-691,共8页
提出了一种新型的太阳能喷射式电热(冷)联供系统,该系统基于有机工质朗肯循环和喷射式制冷循环,利用太阳能光热,通过简单阀门切换实现电冷联供和电热联供。针对西北地区冬季/夏季典型太阳辐照强度,计算系统发电功率和制热(冷)功率,研究... 提出了一种新型的太阳能喷射式电热(冷)联供系统,该系统基于有机工质朗肯循环和喷射式制冷循环,利用太阳能光热,通过简单阀门切换实现电冷联供和电热联供。针对西北地区冬季/夏季典型太阳辐照强度,计算系统发电功率和制热(冷)功率,研究了系统的发电供热(制冷)能力,并从经济性方面进行系统性分析。结果表明:在西北地区太阳辐照强度条件下,该系统能独立满足建筑物的日常用电和供热(制冷)需求;在夏季,最大发电功率为5.42 kW,最大制冷功率为7.26 kW;在冬季,最大制热功率为2.96 kW;系统的电力生产成本为0.755元/(kW·h),相比其他发电系统,在保证低成本的同时,该系统环保可靠且具备供热(制冷)功能。 展开更多
关键词 太阳能 有机工质朗肯循环 电热() 喷射制
下载PDF
Parametric optimization of power system for a micro-CCHP system 被引量:2
2
作者 李应林 张小松 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期297-301,共5页
The universal mathematical model of an engine is established,and an economical zone,in which an engine mainly provides medium output load at medium speed,is presented.Based on the experimental data and the universal m... The universal mathematical model of an engine is established,and an economical zone,in which an engine mainly provides medium output load at medium speed,is presented.Based on the experimental data and the universal model of such an engine above,a mathematical model of a refitted engine is provided.The boundary of the corresponding economical zone is further demarcated,and the optimal operating curve and the operating point of the engine are analyzed.Then,the energy transforming models of the power system are established in the mode of cooling,heating and power(MCHP),the mode of heating and power(MHP)and the mode of electricity powering(MEP).The parameter matching of the power system is optimized according to the transmission ratios of the gear box in the power distribution system.The results show that,in the MCHP,the speed transmission ratio of the engine to the gear box(ies)and the speed transmission ratio of the motor to the gear box(ims)are defined as 2.9 and 1,respectively;in the MHP,when the demand load of the power system is less than the low critical load of the economical zone,the speed transmission ratio of the motor to the engine(ime)is equal to 1,and when the demand load of the power system exceeds the low critical load of the economical zone,ime equals 0.85;in the MEP,the optimal value of ims is defined as 2.5. 展开更多
关键词 combined cooling heating and power distributed energy supply battery bank ENGINE
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
3
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the po... The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the potential to improve the energy generation efficiency of a city or urban region by providing energy for heating, cooling, and electricity simultaneously. The purpose of this study is to estimate the water consumption for energy generation use, carbon dioxide (CO2) and NOx emissions, and economic impact of implementing CCHP systems for five generic building types within the Atlanta metropolitan region, under various operational scenarios following the building thermal (heating and cooling) demands. Operating the CCHP system to follow the hourly thermal demand reduces CO2 emissions for most building types both with and without net metering. The system can be economically beneficial for all building types depending on the price of natural gas, the implementation of net metering, and the cost structure assumed for the CCHP system. The greatest reduction in water consumption for energy production and NOx emissions occurs when there is net metering and when the system is operated to meet the maximum yearly thermal demand, although this scenario also results in an increase in greenhouse gas emissions and, in some cases, cost. CCHP systems are more economical for medium office, large office, and multifamilv residential buildings. 展开更多
关键词 Combined cooling heating and power (CCHP) Air-cooled microturbines Distributed energy generation Water for energy production Net metering
下载PDF
Data Center as a Key Player of a District Electric Power and Heat Network System: A Comparison in Urban and Suburb Regions
4
作者 Shunsuke Mori Yuuki Hori +1 位作者 Masashi Ohkura Kazuhisa Kamegai 《Computer Technology and Application》 2013年第10期548-555,共8页
A DC (data center) demands air-conditioning power as large as the 1/3-1/2 of total electricity consumption. Thus, energy saving of cooling power of DC yields considerable effect on both economic and environmental vi... A DC (data center) demands air-conditioning power as large as the 1/3-1/2 of total electricity consumption. Thus, energy saving of cooling power of DC yields considerable effect on both economic and environmental views. PV (Photovoltaic) and absorption refrigerator with CGS (cogeneration systems) or gas boiler are possible power saving options. The waste warm air from DC would be utilized for greenhouse heating when DC and greenhouse locate near in the suburbs. In this study, the authors develop an energy network model to assess the potential contribution of DC as a major electric power and chilled air consumer as well as the warm air supplier in a district to the energy efficiency improvement. The evaporation heat of LNG (liquefied natural gas) utilization is also considered as well as PV, CGS. This model is applied to the cases of the urban area in Tokyo which involves athletic center, shops and hospital and the suburbs including greenhouse and then compared. 展开更多
关键词 Data center distributed energy systems urban and suburbs.
下载PDF