A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, ...A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, and one capacitance sensor for measuring the aperture of the small blind holes or through holes is introduced. The system is composed of one positioning device, one aperture measuring capacitance sensor, one measuring circuit, and software. This system employs visual CCD and two-dimensional mic...展开更多
The corrosion resistance of C+Mo dual-implanted H13 steel wasstudied using multi-sweep cyclic voltammetry. The phase formation conditions for corrosion resistance and its effects were researched. The super-saturation ...The corrosion resistance of C+Mo dual-implanted H13 steel wasstudied using multi-sweep cyclic voltammetry. The phase formation conditions for corrosion resistance and its effects were researched. The super-saturation solid station solution of Mo+ and C+ atoms was formed in Mo+C dual implanted steel. Precipitate phase with nanometer size Fe2Mo, FeMo, MoC, Fe5C3 and Fe7C3 were formed in dual implanted layer. The passivation layer consisted of these nanometer phases. The corrosion resistance of the dual implanted layer was better than that of single Mo implantation. Jp of the Mo implanted sample is 0.55 times that of H13 steel. The corrosion resistance of the dual implantation was enhanced when ion dose increased. When the Mo+ ion dose was 6×1017/cm2 in the dual implantation, Jp of the dual implanted sample was only 0.11 times that in H13 steel. What is important is that pitting corrosion properties of dual implanted steel were improved obviously.展开更多
文摘A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, and one capacitance sensor for measuring the aperture of the small blind holes or through holes is introduced. The system is composed of one positioning device, one aperture measuring capacitance sensor, one measuring circuit, and software. This system employs visual CCD and two-dimensional mic...
基金This work was supported by the National Natural Science Foundation of China (Grant No. 59671051) 863 Project of National High Science and Technology of China.
文摘The corrosion resistance of C+Mo dual-implanted H13 steel wasstudied using multi-sweep cyclic voltammetry. The phase formation conditions for corrosion resistance and its effects were researched. The super-saturation solid station solution of Mo+ and C+ atoms was formed in Mo+C dual implanted steel. Precipitate phase with nanometer size Fe2Mo, FeMo, MoC, Fe5C3 and Fe7C3 were formed in dual implanted layer. The passivation layer consisted of these nanometer phases. The corrosion resistance of the dual implanted layer was better than that of single Mo implantation. Jp of the Mo implanted sample is 0.55 times that of H13 steel. The corrosion resistance of the dual implantation was enhanced when ion dose increased. When the Mo+ ion dose was 6×1017/cm2 in the dual implantation, Jp of the dual implanted sample was only 0.11 times that in H13 steel. What is important is that pitting corrosion properties of dual implanted steel were improved obviously.