期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
电磁泄漏防护技术——TEMPEST技术 被引量:3
1
作者 姜汇洋 《软件》 2011年第5期123-124,共2页
本文阐述了电磁安全在现代化战争中和日常工作中的重要性,介绍了电磁泄漏危害和电磁泄漏的途径,重点研究电磁泄漏防护技术,并对其涉及的措施进行详细描述和总结。
关键词 电磁泄漏 TEMPEST 屏蔽技术 低辐射技术 电磁干扰器 加密技术
下载PDF
Simulation of Dynamic Electromagnetic Interference Environment for Unmanned Aerial Vehicle Data Link 被引量:10
2
作者 郭淑霞 董中要 +1 位作者 胡占涛 胡楚峰 《China Communications》 SCIE CSCD 2013年第7期19-28,共10页
In order to test the anti-interference ability of an Unmanned Aerial Vehicle(UAV) data link in a complex electromagnetic environment,a method for simulating the dynamic electromagnetic interference of an indoor wirele... In order to test the anti-interference ability of an Unmanned Aerial Vehicle(UAV) data link in a complex electromagnetic environment,a method for simulating the dynamic electromagnetic interference of an indoor wireless environment is proposed.This method can estimate the relational degree between the actual face of an UAV data link in an interface environment and the simulation scenarios in an anechoic chamber by using the Grey Relational Analysis(GRA) theory.The dynamic drive of the microwave instrument produces a real-time corresponding interference signal and realises scene mapping.The experimental results show that the maximal correlation between the interference signal in the real scene and the angular domain of the radiation antenna in the anechoic chamber is 0.959 3.Further,the relational degree of the Signal-toInterference Ratio(SIR) of the UAV at its reception terminal indoors and in the anechoic chamber is 0.996 8,and the time of instrument drive is only approximately 10 μs.All of the above illustrates that this method can achieve a simulation close to a real field dynamic electromagnetic interference signal of an indoor UAV data link. 展开更多
关键词 UAV data link dynamic electromagnetic interference GRA relational degree scene mapping instrument driver
下载PDF
EFT/B interference transmission model and method of anti-interference in a coal mine monitoring substation 被引量:2
3
作者 MA Fengying 《Mining Science and Technology》 EI CAS 2010年第3期391-394,399,共5页
Coal mining monitoring system has been enforcing tests for the immunity of Electromagnetic Compatibility(EMC) since 2006.However,not all monitoring substations can pass the Electrical Fast Transient/Burst(EFT/B) immun... Coal mining monitoring system has been enforcing tests for the immunity of Electromagnetic Compatibility(EMC) since 2006.However,not all monitoring substations can pass the Electrical Fast Transient/Burst(EFT/B) immunity test and the explosion-proof test simultaneously.In order to enhance EMC,the EFT/B interfere transmission model was presented at the substation power port,after the EFT/B test method was used to analyze the monitoring substation power ports.Hence,a low-pass filter was designed by using the simulation software PIPICE and an anti-jamming method was proposed by way of a parallel connection of the discharge interfere circuit and the low-pass filter.The improved complex EMI filter was made up of an interference discharge device and a filter.The dynamic equivalent circuit was proposed for the EFT/B immunity test.As a result,the monitoring substation has passed the EFT/B immunity and explosion-proof tests with the complex filter.It is concluded that the complex EMI filter has significantly enhanced the immunity of the coal mining monitoring system. 展开更多
关键词 coal mining monitoring system EXPLOSION-PROOF electrical fast transient/burst complex filter
下载PDF
Improved direct power injection model of 16-bit microcontroller for electromagnetic immunity prediction 被引量:3
4
作者 高雪莲 田聪颖 +2 位作者 落丽媛 陈银红 陈彦宇 《Journal of Central South University》 SCIE EI CAS 2011年第6期2031-2035,共5页
To promote the modeling standardization process of the integrated circuits, an improved electrical simulation model for a direct power injection (DPI) setup which was used to measure the conducted immunity of a 16-b... To promote the modeling standardization process of the integrated circuits, an improved electrical simulation model for a direct power injection (DPI) setup which was used to measure the conducted immunity of a 16-bit microcontroller to radio frequency aggression was investigated. Based on the existing model of the same microcontroller, the PDN module was modified by adding the core, PLL and MD network models, which could reflect the actual electric distribution situation within the microcontroller more accurately. By comparing the simulation results with the measurement results, the effectiveness of the modified model can be improved to 500 MHz, and its uncertainty is within +1.8 dB (+2 dB is acceptable). Then, to improve the simulation accuracy of the complete model in the high frequency range, the I/O model which contained the dynamic and nonlinear characteristics reflecting the variation of the internal impedance of the microcontroller with increasing the frequency of the external noise was introduced. By comparing the simulation results with the measurement results, the effectiveness of the second modified model can be improved up to 1.4 GHz with the uncertainty of ~1.8 dB. Thus, a conclusion can be reached that the proposed model can be applied to a much wider frequency range with a smaller uncertainty than the latest model of the similar type. Furthermore, associated with the electromagnetic emission testing platform model, the PDN module can also be used to predict the electromagnetic conducted and radiated emission characteristics. This modeling method can also be applied to other integrated circuits, which is very helpful to the standardization of the IC electromagnetic compatibility (EMC) modeling process. 展开更多
关键词 electromagnetic immunity MICROCONTROLLER direct power injection passive distribution network
下载PDF
Evaluation of cable tension sensors of FAST reflector from the perspective of EMI
5
作者 朱明 Wang Qiming +2 位作者 Dennis Egan Wu Mingchang Sun Xiao 《High Technology Letters》 EI CAS 2016年第2期135-141,共7页
The active reflector of FAST ( five-hundred-meter aperture spherical radio telescope) is suppor- ted by a ring beam and a cable-net structure, in which nodes are actively controlled to form series of real-time parab... The active reflector of FAST ( five-hundred-meter aperture spherical radio telescope) is suppor- ted by a ring beam and a cable-net structure, in which nodes are actively controlled to form series of real-time paraboloids. To ensure the security and stability of the supporting structure, tension must be monitored for some typical cables. Considering the stringent requirements in accuracy and long- term stability, magnetic flux sensor, vibrating wire strain gauge and fiber bragg grating strain gauge are screened for the cable tension monitoring of the supporting cable-net. Specifically, receivers of radio telescopes have strict restriction on electro magnetic interference (EMI) or radio frequency in- terference (RFI). These three types of sensors are evaluated from the view of EMIfRFI. Firstly, these fundamentals are theoretically analyzed. Secondly, typical sensor signals are collected in the time and analyzed in the frequency domain, which shows the characteristic in the frequency domain. Finally, typical sensors are tested in an anechoic chamber to get the EMI levels. Theoretical analysis shows that Fiber Bragg Grating strain gauge itself will not lead to EMI/RFI. According to GJB151 A, frequency domain analysis and test results show that for the vibrating wire strain gauge and magnetic flux sensor themselves, testable EMIfRF1 levels are typically below the background noise of the ane- choic chamber. FAST finally choses these three sensors as the monitoring sensors of its cable ten- sion. The proposed study is also a reference to the monitoring equipment selection of other radio tele- scopes and large structures. 展开更多
关键词 five-hundred-meter aperture spherical radio telescope (FAST) cable tension mo-nitoring magnetic flux vibrating wire fiber Bragg electro magnetic interference (EMI)
下载PDF
通过国家保密科技测评中心检测的产品目录
6
《保密科学技术》 2018年第12期69-73,共5页
关键词 证书编号 网络安全管理系统 网络隔离 产品类型 隔离插座 漏洞扫描系统 送检单位 电磁干扰器
原文传递
2018年保密技术交流大会暨产品博览会奖项名单
7
《保密科学技术》 2019年第1期68-69,共2页
关键词 漏洞扫描系统 防火墙 安全网关 电磁干扰器 信息保护系统 网络隔离 隔离插座 协作组 网络安全审计
原文传递
通过国家保密科技测评中心检测的产品目录
8
《保密科学技术》 2017年第10期73-76,共4页
关键词 网络隔离 产品类型 送检单位 证书编号 网络安全审计 电磁干扰器 入侵防御系统 电磁屏蔽 信息安全技术 防火墙 网络信息安全 电子文档 信息保护系统 保密技术
原文传递
通过国家保密科技测评中心检测的产品目录
9
《保密科学技术》 2016年第9期70-72,共3页
关键词 入侵防御系统 有限公司 电磁屏蔽 机柜 北京 辐射屏蔽 审计系统 国保 电磁干扰器 入侵检测系统 信息安全技术 防火墙 漏洞扫描系统 电子文档 安全网关 产品目录 测评中心
原文传递
Prediction of the conducted EMI in PWM converter system with parasitic parameters considered 被引量:6
10
作者 LIANG Bin WEI KeXin YUE YouJun 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第10期2829-2836,共8页
This paper presents a new approach for modeling of the conducted electromagnetic interference(EMI) prediction for widely used converter systems.Coupling paths and mechanism of differential mode(DM) interference and co... This paper presents a new approach for modeling of the conducted electromagnetic interference(EMI) prediction for widely used converter systems.Coupling paths and mechanism of differential mode(DM) interference and common mode(CM) interference have been analyzed.Models to predict the high-frequency noise of PWM converter system are created.A direct calculation method in frequency domain is proposed for the deduction of frequency spectrum.A method is given for obtaining the parasitic parameters and topological structure of the model.An experimental investigation of the conducted emission from an actual high-power rectifier system is described.The validity of the models is confirmed by comparison to laboratory measurements. 展开更多
关键词 parasitic parameter conducted EMI common mode(CM) differential mode(DM)
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部