气体绝缘变电站(gas-insulated substation,GIS)中隔离开关操作产生的瞬态电磁过程是影响智能组件正常工作的主要电磁干扰源,其在二次电缆的传导耦合和辐射耦合干扰分量大的大小研究较少。通过252 k V GIS真型实验平台模拟了变电站快速...气体绝缘变电站(gas-insulated substation,GIS)中隔离开关操作产生的瞬态电磁过程是影响智能组件正常工作的主要电磁干扰源,其在二次电缆的传导耦合和辐射耦合干扰分量大的大小研究较少。通过252 k V GIS真型实验平台模拟了变电站快速瞬态过电压(very fast transient overvoltage,VFTO)产生电磁干扰;测量了不同屏蔽措施条件下二次电缆两端干扰电压水平,得到了电缆端口干扰电压的时域和频域特性。通过统计分析发现辐射耦合是干扰电压产生的主要方式;因此为保证二次电缆安全稳定工作,变电站二次电缆应采取良好的屏蔽措施。展开更多
We present a 3D approach to numerical modeling of the borehole-surface electromagnetic (BSEM) method. The 3D electromagnetic response created by a vertical line current source in a layered medium is modeled using th...We present a 3D approach to numerical modeling of the borehole-surface electromagnetic (BSEM) method. The 3D electromagnetic response created by a vertical line current source in a layered medium is modeled using the 3D integral equation method. The modeling results are consistent with analytical solutions. 3D Born approximation inversion of BSEM data is also conducted for reservoir delineation. The inversion method is verified by a synthetic reservoir model.展开更多
The longitudinal ultrasonic velocity (V1), attenuation (α1), magnetization and resistivity of single phase polycrystalline La1/3Sr2/3CoO3 were measured as a function of temperature from 20 K to 300 K. The resisti...The longitudinal ultrasonic velocity (V1), attenuation (α1), magnetization and resistivity of single phase polycrystalline La1/3Sr2/3CoO3 were measured as a function of temperature from 20 K to 300 K. The resistivity shows metallic behavior in the whole temperature range and a kink at 235 K was observed, which coincides with the ferromagnetic transition temperature (Tc). As the temperature cools down from Tc, the V1 softens conspicuously at beginning and reaches a minimum at 120 K. After that the V1 dramatically stiffens below 120 K accompanied by a wide attenuation peak. The analysis of the results suggests that these ultrasonic anomalies ;nay correspond to local lattice distortions via the Jahn-Teller effect of intermediate spin Co^3+.展开更多
文摘气体绝缘变电站(gas-insulated substation,GIS)中隔离开关操作产生的瞬态电磁过程是影响智能组件正常工作的主要电磁干扰源,其在二次电缆的传导耦合和辐射耦合干扰分量大的大小研究较少。通过252 k V GIS真型实验平台模拟了变电站快速瞬态过电压(very fast transient overvoltage,VFTO)产生电磁干扰;测量了不同屏蔽措施条件下二次电缆两端干扰电压水平,得到了电缆端口干扰电压的时域和频域特性。通过统计分析发现辐射耦合是干扰电压产生的主要方式;因此为保证二次电缆安全稳定工作,变电站二次电缆应采取良好的屏蔽措施。
文摘We present a 3D approach to numerical modeling of the borehole-surface electromagnetic (BSEM) method. The 3D electromagnetic response created by a vertical line current source in a layered medium is modeled using the 3D integral equation method. The modeling results are consistent with analytical solutions. 3D Born approximation inversion of BSEM data is also conducted for reservoir delineation. The inversion method is verified by a synthetic reservoir model.
基金This work was supported by the National Natural Science Foundation of China (No.10774136).
文摘The longitudinal ultrasonic velocity (V1), attenuation (α1), magnetization and resistivity of single phase polycrystalline La1/3Sr2/3CoO3 were measured as a function of temperature from 20 K to 300 K. The resistivity shows metallic behavior in the whole temperature range and a kink at 235 K was observed, which coincides with the ferromagnetic transition temperature (Tc). As the temperature cools down from Tc, the V1 softens conspicuously at beginning and reaches a minimum at 120 K. After that the V1 dramatically stiffens below 120 K accompanied by a wide attenuation peak. The analysis of the results suggests that these ultrasonic anomalies ;nay correspond to local lattice distortions via the Jahn-Teller effect of intermediate spin Co^3+.