In planning and executing marine controlled-source electromagnetic methods, seafloor electromagnetic receivers must overcome the problems of noise, clock drift, and power consumption. To design a receiver that perform...In planning and executing marine controlled-source electromagnetic methods, seafloor electromagnetic receivers must overcome the problems of noise, clock drift, and power consumption. To design a receiver that performs well and overcomes the abovementioned problems, we performed forward modeling of the E-field abnormal response and established the receiver's characteristics. We describe the design optimization and the properties of each component, that is, low-noise induction coil sensor, low-noise Ag/AgCI electrode, low-noise chopper amplifier, digital temperature-compensated crystal oscillator module, acoustic telemetry modem, and burn wire system. Finally, we discuss the results of onshore and offshore field tests to show the effectiveness of the developed seafloor electromagnetic receiver and its performance: typical E-field noise of 0.12 nV/m/rt(Hz) at 0.5 Hz, dynamic range higher than 120 dB, clock drift lower than 1 ms/day, and continuous operation of at least 21 days.展开更多
Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(V...Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP's control strategies is studied. At the first, a wind turbine with the capacity 2.2 k W and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts(including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter(2LVSC) and three-level voltage source converter(3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion(THD) and ripple of rotor torque and flux.展开更多
Coal mining monitoring system has been enforcing tests for the immunity of Electromagnetic Compatibility(EMC) since 2006.However,not all monitoring substations can pass the Electrical Fast Transient/Burst(EFT/B) immun...Coal mining monitoring system has been enforcing tests for the immunity of Electromagnetic Compatibility(EMC) since 2006.However,not all monitoring substations can pass the Electrical Fast Transient/Burst(EFT/B) immunity test and the explosion-proof test simultaneously.In order to enhance EMC,the EFT/B interfere transmission model was presented at the substation power port,after the EFT/B test method was used to analyze the monitoring substation power ports.Hence,a low-pass filter was designed by using the simulation software PIPICE and an anti-jamming method was proposed by way of a parallel connection of the discharge interfere circuit and the low-pass filter.The improved complex EMI filter was made up of an interference discharge device and a filter.The dynamic equivalent circuit was proposed for the EFT/B immunity test.As a result,the monitoring substation has passed the EFT/B immunity and explosion-proof tests with the complex filter.It is concluded that the complex EMI filter has significantly enhanced the immunity of the coal mining monitoring system.展开更多
Due to possible health effects of electric and magnetic fields, a directive on minimum health and safety requirements regarding the exposure of workers to electromagnetic fields has been disposed by European Parliamen...Due to possible health effects of electric and magnetic fields, a directive on minimum health and safety requirements regarding the exposure of workers to electromagnetic fields has been disposed by European Parliament and Council regarding the exposure of workers to electromagnetic fields. This legislation will be nationally implemented in 2012.The aim of this work was to develop a electromagnetic field exposure measurement method and further a magnetic field hazard evaluation method for exposure of workers in indoor medium to low voltage (MV/LV) distribution substations. Magnetic field exposure was also reflected with BS 8800 general risk classification procedure to accomplish specifications to execute magnetic field measurements and carry our risk assessment procedure for working tasks. The risk assessment procedure is based on magnetic field exposure measurements and dosimetric FEM calculations founded on EU Directive 2004/40/EC. According to field measurements action values were exceeded in several working tasks but limit values were not exceeded.展开更多
MHPPs (micro hydro power plants) have become prominent in hydropower plants as a solution to provide the energy demands of the grid. In this study, a new hybrid renewable energy based DC excitation system for synchr...MHPPs (micro hydro power plants) have become prominent in hydropower plants as a solution to provide the energy demands of the grid. In this study, a new hybrid renewable energy based DC excitation system for synchronous generator in the developed MHPP system is introduced. Proposed hybrid DC excitation system consists of solar & hydrogen energy based power generating systems. Hybrid renewable energy based system is used for the excitation of the synchronous generator in the MHPP test system. The renewables are used as a secondary energy source to provide the excitation current to a synchronous generator that generates energy in MHPP. A PV (photovoltaic) array is used as the main source of excitation, and a FC (fuel cell) stack is used for DC excitation in the lack of sunshine. In the experimental setup, an electrical control card is developed, and a microcontroller is used to perform the proposed excitation system. All experimental results obtained from 5 kW rated power MHHP test system. Experimental results show that, the proposed method provides the continuous excitation current, and the operation of the synchronous generator is uninterrupted. The proposed method is also practical and easily implemented for MHPP systems.展开更多
Loop heat pipes (LHPs) were designed for the alpha magnetic spectrometer (AMS-02) to dissipate heat from the cryocoolers. A bypass valve is applied to the LHP to keep the cryocooler temperature above its limit (...Loop heat pipes (LHPs) were designed for the alpha magnetic spectrometer (AMS-02) to dissipate heat from the cryocoolers. A bypass valve is applied to the LHP to keep the cryocooler temperature above its limit (-20℃) in cold environment. Extensive experiments were performed on operation characteristics of LHPs with the bypass valve for AMS-02 during thermal vacuum and thermal balance (TVTB) test. We found that the bypass valve can start up successfully in cold environment. With the bypass valve, the evaporator temperature is stable and can meet the requirement of the cryocooler. We analyzed three operating modes of the bypass valve. Set point temperature and regulation temperature shifts were observed and their relations with the bypass valve temperature were given.展开更多
基金sponsored by the 863 Program(No.2009AA09A2012012AA09A201)+1 种基金China Geological Survey Project(No.201100307)the Fundamental Research Funds of the Ministry of Education for the Central Universities(No.2652011249)
文摘In planning and executing marine controlled-source electromagnetic methods, seafloor electromagnetic receivers must overcome the problems of noise, clock drift, and power consumption. To design a receiver that performs well and overcomes the abovementioned problems, we performed forward modeling of the E-field abnormal response and established the receiver's characteristics. We describe the design optimization and the properties of each component, that is, low-noise induction coil sensor, low-noise Ag/AgCI electrode, low-noise chopper amplifier, digital temperature-compensated crystal oscillator module, acoustic telemetry modem, and burn wire system. Finally, we discuss the results of onshore and offshore field tests to show the effectiveness of the developed seafloor electromagnetic receiver and its performance: typical E-field noise of 0.12 nV/m/rt(Hz) at 0.5 Hz, dynamic range higher than 120 dB, clock drift lower than 1 ms/day, and continuous operation of at least 21 days.
基金the output of a research project (Title: Application of Doubly Fed Asynchronous machine in Pumped Storage Hydropower Plant in Generate Mode, supported by Islamic Azad University South Tehran Branch)
文摘Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP's control strategies is studied. At the first, a wind turbine with the capacity 2.2 k W and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts(including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter(2LVSC) and three-level voltage source converter(3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion(THD) and ripple of rotor torque and flux.
基金supported by the National Natural Science Foundation of China (No.50674093)the Pingdingshan Coal Co.Ltd. The EMI distribution measurements were obtained from several coal mines of the Pingdingshan Coal Co.
文摘Coal mining monitoring system has been enforcing tests for the immunity of Electromagnetic Compatibility(EMC) since 2006.However,not all monitoring substations can pass the Electrical Fast Transient/Burst(EFT/B) immunity test and the explosion-proof test simultaneously.In order to enhance EMC,the EFT/B interfere transmission model was presented at the substation power port,after the EFT/B test method was used to analyze the monitoring substation power ports.Hence,a low-pass filter was designed by using the simulation software PIPICE and an anti-jamming method was proposed by way of a parallel connection of the discharge interfere circuit and the low-pass filter.The improved complex EMI filter was made up of an interference discharge device and a filter.The dynamic equivalent circuit was proposed for the EFT/B immunity test.As a result,the monitoring substation has passed the EFT/B immunity and explosion-proof tests with the complex filter.It is concluded that the complex EMI filter has significantly enhanced the immunity of the coal mining monitoring system.
文摘Due to possible health effects of electric and magnetic fields, a directive on minimum health and safety requirements regarding the exposure of workers to electromagnetic fields has been disposed by European Parliament and Council regarding the exposure of workers to electromagnetic fields. This legislation will be nationally implemented in 2012.The aim of this work was to develop a electromagnetic field exposure measurement method and further a magnetic field hazard evaluation method for exposure of workers in indoor medium to low voltage (MV/LV) distribution substations. Magnetic field exposure was also reflected with BS 8800 general risk classification procedure to accomplish specifications to execute magnetic field measurements and carry our risk assessment procedure for working tasks. The risk assessment procedure is based on magnetic field exposure measurements and dosimetric FEM calculations founded on EU Directive 2004/40/EC. According to field measurements action values were exceeded in several working tasks but limit values were not exceeded.
文摘MHPPs (micro hydro power plants) have become prominent in hydropower plants as a solution to provide the energy demands of the grid. In this study, a new hybrid renewable energy based DC excitation system for synchronous generator in the developed MHPP system is introduced. Proposed hybrid DC excitation system consists of solar & hydrogen energy based power generating systems. Hybrid renewable energy based system is used for the excitation of the synchronous generator in the MHPP test system. The renewables are used as a secondary energy source to provide the excitation current to a synchronous generator that generates energy in MHPP. A PV (photovoltaic) array is used as the main source of excitation, and a FC (fuel cell) stack is used for DC excitation in the lack of sunshine. In the experimental setup, an electrical control card is developed, and a microcontroller is used to perform the proposed excitation system. All experimental results obtained from 5 kW rated power MHHP test system. Experimental results show that, the proposed method provides the continuous excitation current, and the operation of the synchronous generator is uninterrupted. The proposed method is also practical and easily implemented for MHPP systems.
基金supported by the Major Project of Technology Transfer of Shandong Province (Grant No. 2009ZHZX1A1105)
文摘Loop heat pipes (LHPs) were designed for the alpha magnetic spectrometer (AMS-02) to dissipate heat from the cryocoolers. A bypass valve is applied to the LHP to keep the cryocooler temperature above its limit (-20℃) in cold environment. Extensive experiments were performed on operation characteristics of LHPs with the bypass valve for AMS-02 during thermal vacuum and thermal balance (TVTB) test. We found that the bypass valve can start up successfully in cold environment. With the bypass valve, the evaporator temperature is stable and can meet the requirement of the cryocooler. We analyzed three operating modes of the bypass valve. Set point temperature and regulation temperature shifts were observed and their relations with the bypass valve temperature were given.