In order to improve the efficiency of a geothermal power plant, oil wells in the high water cut stage were used as geothermal wells, thereby improving the recovery ratio and economic benefit. A new function that refle...In order to improve the efficiency of a geothermal power plant, oil wells in the high water cut stage were used as geothermal wells, thereby improving the recovery ratio and economic benefit. A new function that reflects both the technical and economic performances was put forward and used as the objective function. An organic Rankine cycle (ORC) was analyzed through the energetic and exergetic analyses, and the reasons for low efficiency were pinpointed. Results indicate that geothermal water directly transferring heat to the working fluid reduces energy dissipation and increases cycle efficiencies. The net power output with an internal heat exchanger (IHE) is averagely 5.3% higher than that without an IHE. R601a and R601 can be used to replace R123 for geothermal water below 110℃. Moreover, the modified ORC dramatically outperforms the actual one.展开更多
With the growing energetic need present in the world, it is increasingly necessary for the researches and facilities to seek a better use of renewable natural resources. This paper is applied in the study of the perfo...With the growing energetic need present in the world, it is increasingly necessary for the researches and facilities to seek a better use of renewable natural resources. This paper is applied in the study of the performance of the aeration system of the Francis turbines present in Itaipu Hydroelectric Power Plant. When a Francis turbine operates off its optimal conditions, a vortex is formed inside the draft tube that, besides produces cavitation and pressure fluctuations, can pulse at frequencies with risk of resonance with hydraulic system, producing efforts and vibrations that may cause structural failures in the turbines, generators and civil parts of the power house. These damaging effects can be reduced using atmospheric aeration of the turbines. Because of this, the availability and effectively of the aeration system is fundamental to smooth the behavior of the turbines, helping preserve the health of the power plant. An analysis of the performance of the aeration system will be done using maintenance records and disturbances analysis reports (RAP), allowing verification of the operating conditions of the turbine and fatality of water inlet in air pipes. Through the improvements detected, it is possible to reduce machine stoppages by tripping, thus increasing the availability of the turbines.展开更多
The mechanic properties, lasting strength and microstructural properties of straight and elbow pipesof 12CrMo, 10CrMo910 and 12CrlMoV low alloy steel main steam piping system after long-time service weretested and stu...The mechanic properties, lasting strength and microstructural properties of straight and elbow pipesof 12CrMo, 10CrMo910 and 12CrlMoV low alloy steel main steam piping system after long-time service weretested and studied. The testing results showed that, for straight and elbow pipes of mainsteam piping under theconditions of high temperature and high pressure, the numerical operating performance indexes of their metalchanged with little difference, generally both within 5%, and the Values of elbow were higher than those ofstraight pipes. These phenomena proved that the aging processes of pipe metal at different positions are thesame. And the cause for higher numerical performance indexes of elbow and higher failure rate at elbow posi-tion during operation of steam pipes were investigated.展开更多
The paper investigated the performance of a solar chimney, by measuring the chimney air temperature and velocity. A short solar chimney prototype was designed and constructed at Botswana Technology Center. A wind turb...The paper investigated the performance of a solar chimney, by measuring the chimney air temperature and velocity. A short solar chimney prototype was designed and constructed at Botswana Technology Center. A wind turbine was installed to rotate a small DC generator. Temperatures and velocities were measured at different times of the day with thermocouples and hotwire anemometer, respectively. Irradiance was measured with pyranometer. A Delta-T data logger was used to store data at intervals of 30 s. Various graphs depicting the influence of irradiance on temperature, velocity and power have been plotted. Irradiance was found to affect the chimney temperature and subsequently affects chimney air velocity and power produced. Ambient air (wind) velocity was found to have influence on the performance of the solar chimney by increasing chimney air velocity.展开更多
基金Project(2012AA052804) supported by the National High Technology Research and Development Program of China
文摘In order to improve the efficiency of a geothermal power plant, oil wells in the high water cut stage were used as geothermal wells, thereby improving the recovery ratio and economic benefit. A new function that reflects both the technical and economic performances was put forward and used as the objective function. An organic Rankine cycle (ORC) was analyzed through the energetic and exergetic analyses, and the reasons for low efficiency were pinpointed. Results indicate that geothermal water directly transferring heat to the working fluid reduces energy dissipation and increases cycle efficiencies. The net power output with an internal heat exchanger (IHE) is averagely 5.3% higher than that without an IHE. R601a and R601 can be used to replace R123 for geothermal water below 110℃. Moreover, the modified ORC dramatically outperforms the actual one.
文摘With the growing energetic need present in the world, it is increasingly necessary for the researches and facilities to seek a better use of renewable natural resources. This paper is applied in the study of the performance of the aeration system of the Francis turbines present in Itaipu Hydroelectric Power Plant. When a Francis turbine operates off its optimal conditions, a vortex is formed inside the draft tube that, besides produces cavitation and pressure fluctuations, can pulse at frequencies with risk of resonance with hydraulic system, producing efforts and vibrations that may cause structural failures in the turbines, generators and civil parts of the power house. These damaging effects can be reduced using atmospheric aeration of the turbines. Because of this, the availability and effectively of the aeration system is fundamental to smooth the behavior of the turbines, helping preserve the health of the power plant. An analysis of the performance of the aeration system will be done using maintenance records and disturbances analysis reports (RAP), allowing verification of the operating conditions of the turbine and fatality of water inlet in air pipes. Through the improvements detected, it is possible to reduce machine stoppages by tripping, thus increasing the availability of the turbines.
文摘The mechanic properties, lasting strength and microstructural properties of straight and elbow pipesof 12CrMo, 10CrMo910 and 12CrlMoV low alloy steel main steam piping system after long-time service weretested and studied. The testing results showed that, for straight and elbow pipes of mainsteam piping under theconditions of high temperature and high pressure, the numerical operating performance indexes of their metalchanged with little difference, generally both within 5%, and the Values of elbow were higher than those ofstraight pipes. These phenomena proved that the aging processes of pipe metal at different positions are thesame. And the cause for higher numerical performance indexes of elbow and higher failure rate at elbow posi-tion during operation of steam pipes were investigated.
文摘The paper investigated the performance of a solar chimney, by measuring the chimney air temperature and velocity. A short solar chimney prototype was designed and constructed at Botswana Technology Center. A wind turbine was installed to rotate a small DC generator. Temperatures and velocities were measured at different times of the day with thermocouples and hotwire anemometer, respectively. Irradiance was measured with pyranometer. A Delta-T data logger was used to store data at intervals of 30 s. Various graphs depicting the influence of irradiance on temperature, velocity and power have been plotted. Irradiance was found to affect the chimney temperature and subsequently affects chimney air velocity and power produced. Ambient air (wind) velocity was found to have influence on the performance of the solar chimney by increasing chimney air velocity.