A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was...A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of Lab VIEW.The two-dimensional(2D) scatter plots of the charge in the slow component vs.the total charge from ^(241)Am-Be and ^(252)Cf neutron sources are presented.The 2D scatter plots of the energy vs.the ratio of the charge in the slow component to the total charge of the pulses are also presented.The quality of n-γ discrimination was checked by the figure-of-merit,and the results showed good performance of n-γ discrimination at the low energy range.Neutrons and γ-rays were separated above 50 keVee(electron-equivalent energy).The quality of n-γ discrimination has been improved compared with others' results at five energies(150,250,350,450,550 keVee).展开更多
A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in...A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in Lab VIEW, with a sampling frequency up to 1.6 GS/s. Standard gamma sources22 Na,137Cs and60 Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function was obtained. Digital algorithms for the charge comparison method and zero-crossing method have been developed. The experimental results show that both digital signal processing(DSP) algorithms can discriminate neutrons from γ-rays. Moreover,the zero-crossing method shows better n-γ discrimination at 80 ke Vee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit(FOM) for detectors of two different dimensions were extracted at 9 energy thresholds, and it was found that the smaller detector presented better n-γseparation for fission neutrons.展开更多
文摘A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of Lab VIEW.The two-dimensional(2D) scatter plots of the charge in the slow component vs.the total charge from ^(241)Am-Be and ^(252)Cf neutron sources are presented.The 2D scatter plots of the energy vs.the ratio of the charge in the slow component to the total charge of the pulses are also presented.The quality of n-γ discrimination was checked by the figure-of-merit,and the results showed good performance of n-γ discrimination at the low energy range.Neutrons and γ-rays were separated above 50 keVee(electron-equivalent energy).The quality of n-γ discrimination has been improved compared with others' results at five energies(150,250,350,450,550 keVee).
基金Supported by National Natural Science Foundation of China(91226107,11305229)the Strategic Priority Research Program of the Chinese Academy of Sciences(XDA03030300)
文摘A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in Lab VIEW, with a sampling frequency up to 1.6 GS/s. Standard gamma sources22 Na,137Cs and60 Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function was obtained. Digital algorithms for the charge comparison method and zero-crossing method have been developed. The experimental results show that both digital signal processing(DSP) algorithms can discriminate neutrons from γ-rays. Moreover,the zero-crossing method shows better n-γ discrimination at 80 ke Vee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit(FOM) for detectors of two different dimensions were extracted at 9 energy thresholds, and it was found that the smaller detector presented better n-γseparation for fission neutrons.